9 - 2
Storage A single character that specifies the storage table to which the
command is applied. An exclamation point (
!
) performs the command’s
operation on the device’s volatile menu configuration table. A period (
.
)
performs the command’s operation on the device’s non-volatile menu
configuration table. Use the non-volatile table only for semi-permanent
changes you want saved through a power cycle.
Query Commands
Several special characters can be used to query the device about its settings.
^
What is the default value for the setting(s).
?
What is the device’s current value for the setting(s).
*
What is the range of possible values for the setting(s). (The device’s
response uses a dash (
-
) to indicate a continuous range of values. A
pipe (
|
) separates items in a list of non-continuous values.)
:Name: Field Usage (Optional)
This command returns the query information from the scanner.
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the
entire
set of commands available for the particular storage table indicated by the
Storage field of the command. In this case, the SubTag and Data fields
should not be used because they are ignored by the device.
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to
the subset of commands available that match the Tag field. In this case,
the Data field should not be used because it is ignored by the device.
Data Field Usage
When a query is used in place of the Data field, the query applies only to
the specific command identified by the Tag and SubTag fields.
Concatenation of Multiple Commands
Multiple commands can be issued within one Prefix/Storage sequence.
Only the Tag, SubTag, and Data fields must be repeated for each com-
mand in the sequence. If additional commands are to be applied to the
same Tag, then the new command sequence is separated with a comma (
,
)
and only the SubTag and Data fields of the additional command are issued.
If the additional command requires a different Tag field, the command is
separated from previous commands by a semicolon (
;
).
Summary of Contents for VOYAGER 1250G
Page 1: ... VoyagerTM 1250g Single Line Laser Scanner User s Guide ...
Page 8: ......
Page 78: ...3 22 ...
Page 88: ...4 10 ...
Page 100: ...5 12 ...
Page 170: ...7 4 ...
Page 217: ...9 43 ...
Page 218: ...9 44 ...
Page 226: ...11 4 ...
Page 241: ......
Page 243: ...Sample Symbols 6543210 GS1 DataBar 01 00123456789012 Matrix 2 of 5 ...
Page 244: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...
Page 246: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 VG1250 UG Rev D 9 13 ...