background image

Gryphon

 I GFS4100 

Fixed Mount Linear Imager 

Bar Code Reader 

Product Reference Guide

Summary of Contents for Gryphon GFS4100

Page 1: ...Gryphon I GFS4100 Fixed Mount Linear Imager Bar Code Reader Product Reference Guide ...

Page 2: ...alogic website www scanning data logic com or provided on appropriate media If you visit our website and would like to make comments or sugges tions about this or other Datalogic publications please let us know via the Contact Datalogic page Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate how ever Datalogic reserves the right t...

Page 3: ...ission 15 Resetting Product Configuration to Defaults 16 CONFIGURATION USING BARCODES 17 Configuration Parameters 17 Reading Configuration Barcodes 18 GLOBAL INTERFACE FEATURES 19 Host Commands Obey Ignore 19 RS 232 ONLY Interface 21 Baud Rate 22 Data Bits 23 Stop Bits 23 Parity 24 Handshaking Control 25 RS 232 USB Com Interfaces 26 Intercharacter Delay 27 Beep On ASCII BEL 27 Beep On Not on File ...

Page 4: ... to Indicate 67 Good Read Beep 67 Good Read Beep Length 68 Good Read LED Duration 69 Green Spot Duration 70 LED Indication 70 SCANNING FEATURES 71 Operating Mode 71 Phase Off Event 72 Phase Off Timeout 72 Serial Start Character 73 Serial Stop Character 73 Automatic Threshold 74 Test Mode Multiple 74 CAMERA CONTROL 75 Exposure Mode 75 Code Selection 77 DISABLE ALL SYMBOLOGIES 78 CODE EAN UPC 79 Cou...

Page 5: ...08 Code 39 Full ASCII 108 Code 39 Quiet Zones 109 Code 39 Minimum Reads 110 Code 39 Decoding Level 111 Code 39 Length Control 112 Code 39 Set Length 1 113 Code 39 Set Length 2 114 Code 39 Interdigit Ratio 115 Code 39 Character Correlation 117 Code 39 Stitching 117 CODE 32 ITAL PHARMACEUTICAL CODE 118 Code 32 Enable Disable 118 Code 32 Feature Setting Exceptions 118 Code 32 Check Char Transmission ...

Page 6: ...e Disable 148 Industrial 2 of 5 Check Character Calculation 148 Industrial 2 of 5 Check Character Transmission 149 Industrial 2 of 5 Length Control 149 Industrial 2 of 5 Set Length 1 150 Industrial 2 of 5 Set Length 2 151 Industrial 2 of 5 Minimum Reads 152 Industrial 2 of 5 Character Correlation 152 Industrial 2 of 5 Stitching 153 CODE IATA 154 IATA Enable Disable 154 IATA Check Character Transmi...

Page 7: ... 182 CODE 93 183 Code 93 Enable Disable 183 Code 93 Check Character Calculation 183 Code 93 Check Character Transmission 184 Code 93 Length Control 184 Code 93 Set Length 1 185 Code 93 Set Length 2 186 Code 93 Minimum Reads 187 Code 93 Decoding Level 188 Code 93 Quiet Zones 189 Code 93 Character Correlation 190 Code 93 Stitching 190 MSI 191 MSI Enable Disable 191 MSI Check Character Calculation 19...

Page 8: ...est Mode 253 Test Mode Multiple 254 Camera Control 254 Power Save 254 USB Suspend 254 Sleep Mode Timeout 254 Digital Output 255 Symbologies 255 Decoding Level 255 Set Length 255 TECHNICAL SPECIFICATIONS 257 Standard Cable Pinouts 259 LED and Beeper Indications 260 Button and LED Status 260 Error Codes 261 STANDARD DEFAULTS 263 SAMPLE BARCODES 273 KEYPAD 277 RESERVED CHARACTERS 281 SCANCODE TABLES ...

Page 9: ...References provides background information and detailed instructions for more complex programming items Appendix A Technical Specifications lists physical and performance characteristics as well as environmental and regulatory specifications It also provides standard cable pin outs and LED Beeper functions Appendix B Standard Defaults references common factory default settings for reader features ...

Page 10: ...omputer systems and can provide individualized assistance Telephone Technical Support If you do not have internet or email access you may contact Datalogic technical support at 541 349 8283 or check the back cover of your manual for more contact information About the Reader Typically units are factory programmed for the most common terminal and communications settings If you need to modify any pro...

Page 11: ...parameter settings before scanning the ENTER EXIT barcode a second time which will then accept your changes exit Programming Mode and return the reader to normal operation There are some exceptions to the typical programming sequence described above Please read the description and setting instructions carefully when configuring each programmable feature Datalogic Aladdin Datalogic Aladdin is a mul...

Page 12: ...Introduction 10 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 13: ...he unit ever require service it should be returned in its original shipping container Setting Up the Reader Follow the steps provided in this section to connect and get your reader up and communicating with its host 1 Connect the cable to the Host 2 Go to Interface Selection and set the desired interface 3 Configure Interface Settings only if not using factory settings for that interface 4 Go to S...

Page 14: ...r Plug the AC Adapter barrel connector into the socket on the RS 232 cable connector and the AC Adapter plug into a standard power outlet Figure 1 RS 232 Connection USB Connection Connect the reader to a USB port on the terminal PC using the USB cable for the interface type you ordered Reference Figure 2 Figure 2 USB connection Specific cables are required for connection to different hosts The con...

Page 15: ...ng barcode from this section which selects the appropriate interface type matching the system the reader will be connected to Next proceed to the corresponding section in this manual also listed in Table 1 starting on page 14 to configure any desired settings and features associated with that interface Unlike some programming features and options interface selections require that you scan only one...

Page 16: ... correct USB COM driver from the Datalogic Scanning website USB Com to simulate RS 232 standard interface RS 232 Wincor Nixdorf Select RS 232 Wincor Nixdorf KEYBOARD FEATURES Select USB Keyboard USB Keyboard with standard key encoding Set KEYBOARD Interface Features starting on page 33 USB Keyboard with alternate key encoding Select USB Alternate Keyboard Select USB KBD APPLE USB Keyboard for Appl...

Page 17: ...riate section for your interface type in Configuration Using Barcodes starting on page 17 RS 232 ONLY Interface on page 21 RS 232 USB Com Interfaces on page 26 USB Keyboard Interfaces on page 33 Global Interface Features See Global Interface Features on page 19 for settings configurable by all interface types Software Version Transmission The software version of the device can be transmitted over ...

Page 18: ... Restore Custom Default Configuration Custom defaults are based on the interface type Configure the imager for the correct interface before scanning this label Restore Factory Configuration If you want to restore the Factory Configuration for your imager scan the Restore Factory Configuration barcode below The label restores the scanner configuration to the factory settings including the interface...

Page 19: ...iguration in order to set the default values and select the interface for your application The following configuration parameters are applicable to all Gryphon models covered in this manual unless otherwise indicated The items are divided into logical groups making it easy to find the desired function based on its reference group Interface Configuration RS 232 ONLY Interface on page 21 RS 232 USB ...

Page 20: ...and possibly the facing page to ensure that the reader reads only the barcode you intend to scan 3 If additional input parameters are needed go to Appendix D Keypad and scan the appro priate characters from the keypad Additional information about many features can be found in the Refer ences chapter If you make a mistake before the last character scan the CANCEL barcode to abort and not save the e...

Page 21: ...ble by all interface types Host Commands Obey Ignore This option specifies whether the reader will obey or ignore host commands When set to ignore the reader will ignore all host commands except for those necessary for service mode flash programming mode keeping the interface active transmission of labels DEFAULT Host Commands Obey Host Commands Ignore ...

Page 22: ...Configuration Using Barcodes ENTER EXIT PROGRAMMING MODE 20 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 23: ...ramming barcodes in this section if modifications to the standard RS 232 interface settings are necessary to meet your system s requirements Additional settings which apply to both the RS 232 and USB interfaces are available in the next section RS 232 USB Com Interfaces starting on page 4 26 Reference Appendix B Standard Defaults for a listing of standard factory settings ...

Page 24: ...OGRAMMING MODE 22 Gryphon I GFS4170 GFS4150 9 Baud Rate See page 233 for information on this feature Baud Rate 1200 Baud Rate 2400 Baud Rate 4800 Baud Rate 9600 DEFAULT Baud Rate 19 200 Baud Rate 38 400 Baud Rate 57 600 Baud Rate 115 200 ...

Page 25: ...s the reader to interface with devices requiring a 7 bit or 8 bit ASCII protocol for sending and receiving data 7 Data Bits 8 Data Bits DEFAULT Stop Bits Set the number of stop bits to match host device requirements See page 233 for more information on this feature DEFAULT 1 Stop Bit 2 Stop Bits ...

Page 26: ...DE 24 Gryphon I GFS4170 GFS4150 9 Parity This feature specifies parity required for sending and receiving data Select the parity type according to host device requirements See page 233 for more information DEFAULT Parity None Parity Even Parity Odd ...

Page 27: ... Reference Guide 25 Handshaking Control DEFAULT Handshaking Control RTS Handshaking Control RTS CTS Handshaking Control RTS XON XOFF Handshaking Control RTS On CTS Handshaking Control RTS CTS Scan Control See page 233 for more information about this feature ...

Page 28: ...ARACTER on page 29 ACK NAK TIMEOUT VALUE on page 30 ACK NAK RETRY COUNT on page 30 ACK NAK ERROR HANDLING on page 31 INDICATE TRANSMISSION FAILURE on page 31 DISABLE CHARACTER on page 32 ENABLE CHARACTER on page 32 The programming barcodes in this chapter allow modifications to the standard RS 232 and USB Com interfaces Reference Appendix B Standard Defaults for a listing of standard factory setti...

Page 29: ...n the ENTER EXIT PROGRAM MING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT barcode again Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again CANCEL DEFAULT 00 No Intercharacter Delay Beep On ASCII ...

Page 30: ...st command Beep On Not On File Disable DEFAULT Beep On Not On File Enable ACK NAK Options This enables disables the ability of the reader to support the RS 232 ACK NAK protocol See page 235 for more information DEFAULT ACK NAK Protocol Disable ACK NAK ACK NAK Protocol Enable for label transmission ACK NAK Protocol Enable for host command acknowledge ACK NAK Protocol Enable for label transmission a...

Page 31: ...data is not recognized when the option Data Bits has been set as 7 Data Bits NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character ASCII characters or any hex value from 0 to 0xFF can be selected Setting to previously defined characters such as XON XOFF or host com mands conflicts with normal operation of these characters 8 bit data is not recognized ...

Page 32: ...in Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the begin ning CANCEL DEFAULT 01 ACK NAK Timeout value is 200ms ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition The selectable range is from 1 to 254 retries A selection of 0 disables the count and a selection o...

Page 33: ...EFAULT ACK NAK Error Handling Ignore Errors Detected ACK NAK Error Handling Process Error as Valid ACK Character ACK NAK Error Handling Process Error as Valid NAK Character Indicate Transmission Failure This option enables disables the reader s ability to sound an error beep to indicate a transmission failure while in ACK NAK mode Indicate Transmission Failure Disable Indication Indicate Transmiss...

Page 34: ...feature Select Disable Character Setting DEFAULT 0x44 Disable Character is D Enable Character Specifies the value of the RS 232 host command used to enable the reader ASCII characters or any hex value from 0 to 0xFF can be selected Setting to previously defined characters such as XON XOFF or host com mands conflicts with normal operation of these characters 8 bit data is not recognized when Data B...

Page 35: ...BOARD SPEED on page 38 Use the programming barcodes in this chapter to select options for USB Keyboard Interfaces Reference Appendix B Standard Defaults for a listing of standard factory settings Information about control character emulation which applies to keyboard interfaces is listed in Appendix F Scancode Tables ...

Page 36: ...interface supports ALL Country Modes All other interfaces support ONLY the following Country Modes U S Belgium Britain France Germany Italy Spain Sweden DEFAULT Country Mode U S Country Mode Belgium Country Mode Britain Country Mode Croatia Supports only the interfaces listed in the Country Mode fea ture description Supports only the interfaces listed in the Country Mode feature description Countr...

Page 37: ...d in the Country Mode feature description Country Mode Hungary Country Mode Italy Supports only the interfaces listed in the Country Mode feature description Country Mode Japanese 106 key Country Mode Norway Supports only the interfaces listed in the Country Mode fea ture description ENTER EXIT PROGRAMMING MODE Country Mode Product Reference Guide 35 Country Mode continued ...

Page 38: ...he interfaces listed in the Country Mode feature description Country Mode Portugal Country Mode Romania Supports only the interfaces listed in the Country Mode fea ture description Supports only the interfaces listed in the Country Mode feature description Country Mode Slovakia Country Mode Spain Country Mode Sweden Country Mode Switzerland Supports only the interfaces listed in the Country Mode f...

Page 39: ...0 to 0x1F are sent as control character Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 00 to 0x1F are sent as control character Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table Microsoft Windows Codepage 1252 se...

Page 40: ...MMING MODE 38 Gryphon I GFS4170 GFS4150 9 USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard DEFAULT USB Keyboard Speed 1ms USB Keyboard Speed 2ms USB Keyboard Speed 3ms USB Keyboard Speed 4ms USB Keyboard Speed 5ms ...

Page 41: ...oard Speed 6ms USB Keyboard Speed 7ms USB Keyboard Speed 8ms USB Keyboard Speed 9ms USB Keyboard Speed 10ms ENTER EXIT PROGRAMMING MODE USB Keyboard Speed Product Reference Guide 39 USB Keyboard Speed continued ...

Page 42: ...USB Keyboard Interfaces ENTER EXIT PROGRAMMING MODE 40 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 43: ...y Selection SET GLOBAL MID LABEL ID CHARAC TERS on page 50 NO READ STRING on page 51 CODE VERIFIER starting on page 52 Code Verifier Mode Match String Wrong Code String CASE CONVERSION on page 54 CHARACTER CONVERSION on page 55 The features in this chapter can be used to build specific user defined data into a message string See References starting on page 241 for more detailed instructions on set...

Page 44: ...s feature scan the ENTER EXIT PROGRAMMING MODE barcode above to place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix barcode followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s If less than the expected string of 20 characters are selected scan the ENTER EXIT barcode to terminate the string Exit pro...

Page 45: ...e characters as follows A close brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN Ea a UPC A and UPC E labels are converted to EAN 13 when adding AIM IDs Code 128 GS1 128 C Code 39 and Code 32 A DataBar Omnidirectional DataBar Expanded e Codabar F Standard 2 of 5 S...

Page 46: ...re provides options for configuring custom Label IDs as a pre loaded set see Label ID Pre loaded Sets below or individually per symbology see Label ID Set Individually Per Symbology on page 45 If you wish to program the reader to always include an industry standard label identifier for ALL symbology types see the previous feature Global AIM ID on page 43 See Label ID starting on page 244 of Refere...

Page 47: ...re configures a Label ID individually for a single symbology See Label ID Set Individually Per Symbology starting on page 246 for detailed instructions on setting this feature Label ID Control This option controls whether a Label ID is disabled or sent as a prefix or suffix for a given symbology type DEFAULT Label ID Transmission Disable Label ID Transmission Enable as Prefix Label ID Transmission...

Page 48: ...h a Label ID is to be configured See Label ID on page 44 or page 246 in References for more Set UPC A Label ID Character s Set UPC A P2 Label ID Character s Set UPC A P5 Label ID Character s Set UPC E Label ID Character s Set UPC E P2 Label ID Character s Set UPC E P5 Label ID Character s Set EAN 13 Label ID Character s detailed instructions ...

Page 49: ...Symbology Selection continued Set EAN 13 P2 Label ID Character s Set EAN 13 P5 Label ID Character s Set EAN 8 Label ID Character s Set EAN 8 P2 Label ID Character s Set EAN 8 P5 Label ID Character s Set GTIN Label ID Character s Set GTIN P2 Label ID Character s Set GTIN P5 Label ID Character s ...

Page 50: ...n continued Set Code 39 Label ID Character s Set Code 32 Label ID Character s Set Code 39 CIP Label ID Character s Set Code 128 Label ID Character s Set GS1 128 Label ID Character s Set ISBT 128 Label ID Character s Set Interleaved 2 of 5 Label ID Character s Set Standard 2 of 5 Label ID Character s ...

Page 51: ...logy Selection continued Set Industrial 2 of 5 Label ID Character s Set IATA Label ID Character s Set Datalogic 2 of 5 Label ID Character s Set Codabar Label ID Character s Set ABC Codabar Label ID Character s Set DataBar Omnidirectional Label ID Character s Set DataBar Expanded Label ID Character s ...

Page 52: ... transmission between the labels of a two label pair Set Global Mid Label ID Character s To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scan ning the ENTER EXIT barcode again Make a mistake Scan the CANCEL barcode to...

Page 53: ...ER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s If less than the expected string of 20 characters are selected scan the ENTER EXIT barcode to terminate the string End by scanning the ENTER EXIT barcode again Make a mistake Scan the CANCEL barcode to abort and no...

Page 54: ... read matches the code verifier Match String then it is sent to the host through the configured port If it does not match the code verifier Match String you can specify whether to send either the Wrong Code or a defined Wrong String message to indicate the error See page 249 in References for more information about these features Code Verifier Mode Disable or specify parameters for Code Verifier M...

Page 55: ...ssible to define the Match string by inserting all printable characters non printable ASCII characters No wild card characters are supported Set Match String To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scan ning t...

Page 56: ...XIT barcode again Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the beginning CANCEL See page 250 in References for more information about this feature Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case DEFAULT Case Conversion Disable no case conversion Case Conversion Convert to...

Page 57: ...s done Configure Character Conversion To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scan ning the ENTER EXIT barcode again Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then s...

Page 58: ...Data Format ENTER EXIT PROGRAMMING MODE 56 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 59: ... 59 DEACTIVATION TIMEOUT on page 59 ACTIVATION STATE on page 60 See page 255 in References for more information about Digital Output Use the programming barcodes in this chapter to select options for Digital Outputs Reference Appendix B Standard Defaults for a listing of standard factory settings ...

Page 60: ...Digital Output ENTER EXIT PROGRAMMING MODE 58 Gryphon I GFS4170 GFS4150 9 Activation Event Defines the event activating the output Disable DEFAULT Good Read No Read Wrong Code ...

Page 61: ... this specifies the maximum duration of the output pulse Set Deactivation Timeout To configure this feature scan the ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s Exit pro gramming mode by scanning the ENTER EXIT barcode again Make a mistake Scan the CANCEL...

Page 62: ...Digital Output ENTER EXIT PROGRAMMING MODE 60 Gryphon I GFS4170 GFS4150 9 Activation State Determines the active state of the output Closed DEFAULT Open ...

Page 63: ...1 POWER SAVE USB SUSPEND MODE on page 62 SLEEP MODE TIMEOUT on page 63 Use the programming barcodes in this chapter to select Power Save options Reference Appendix B Standard Defaults for a listing of standard factory settings ...

Page 64: ...9 USB Suspend Mode This setting enables disables the ability of USB interfaces to enter suspend mode See page 254 in References for more information about this feature DEFAULT USB Suspend Mode Disable USB Suspend Mode Enable All LED indicators are off during USB Suspend ...

Page 65: ...s from the Host or base station until it is woken up again either by a trigger pull or when an external trigger event occurs See page 254 in References for more information about this feature Sleep Mode Timeout Disable DEFAULT Sleep Mode Timeout 10 Seconds Sleep Mode Timeout 30 Seconds Sleep Mode Timeout 1 minute Sleep Mode Timeout 5 minutes Sleep Mode Timeout 10 minutes This feature is available ...

Page 66: ...Power Save ENTER EXIT PROGRAMMING MODE 64 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 67: ...rt Good Read When to Indicate Good Read Beep Good Read Beep Length Good Read LED Duration Green Spot Duration LED Indication SCANNING FEATURES on page 71 Operating Mode Phase Off Event Phase Off Timeout Serial Start Character Serial Stop Character Automatic Threshold Test Mode Multiple CAMERA CONTROL on page 75 Exposure Mode ...

Page 68: ...ggered the illuminator is turned on when the reading phase starts and turned off as soon as the code s are read or when the reading phase ends Illumination Mode Disabled Illumination Mode Enabled Illumination Mode Triggered DEFAULT LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication from the Beeper that the reader is receiving power Power On Alert Disable No Audible Indicat...

Page 69: ...provide indication beep and or flash its green LED upon successfully reading a barcode DEFAULT Indicate Good Read On Decode Indicate Good Read After Transmit This option which uses CTS is only valid for RS 232 interfaces Good Read Beep Enable Disable the good read beep following a good read of a label DEFAULT Enable Good Read Beep Disable Good Read Beep ...

Page 70: ...9 Good Read Beep Length Good Read Beep Length 60 msec Good Read Beep Length 80 msec DEFAULT Good Read Beep Length 100 msec Good Read Beep Length 120 msec Good Read Beep Length 140 msec Good Read Beep Length 160 msec Good Read Beep Length 180 msec Good Read Beep Length 200 msec ...

Page 71: ...ed instructions and examples for setting this feature Select Good Read LED Duration Setting Toconfigure this feature scanthe ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT barcode again Make a mistake Scan the CANCEL barcode to...

Page 72: ... Spot Duration Short 300 msec DEFAULT Green Spot Duration Medium 500 msec Green Spot Duration Long 800 msec LED Indication Specifies when the scanner s LEDs will provide notification of successful reading of a barcode Selections On Decode Indicate Good Read immediately after decoding After Transmission Indicate Good Read after code transmission to host LED Indication On Decode DEFAULT LED Indicati...

Page 73: ... FEATURES Operating Mode Selects the reader s scan operating mode See page 252 in References for more information On Line DEFAULT Serial On Line Automatic Automatic Object Sense Test Mode The barcode must remain steady before the reader in order for the Test mode to work properly ...

Page 74: ...crements Select Phase Off Timeout Toconfigure this feature scanthe ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT barcode again Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start ag...

Page 75: ...ial Start Character is 02 STX See page 253 in References for more information Serial Stop Character Select Serial Stop Characters Toconfigure this feature scanthe ENTER EXIT PROGRAMMING MODE barcode above then the barcode at left followed by the digits in hex from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT barcode again Mak...

Page 76: ...nting your desired character s End by scanning the ENTER EXIT barcode again Make a mistake Scan the CANCEL barcode to abort and not save the entry string You can then start again at the begin ning CANCEL DEFAULT 0x0A 10 See page 253 in References for more information Test Mode Multiple This parameter is active only in Test Mode Disable Test mode is possible only for a single barcode Enable Test mo...

Page 77: ...formance on moving barcodes can be improved by flashing the scanner s lighting strobe mode The scanner strobes at a very high frequency so the change in lighting may not be apparent When enabled the scanner can read codes moving at up to 1m sec depending on the bar size and direction the code is moving Continuous DEFAULT Strobed ...

Page 78: ...Reading Parameters 76 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 79: ...GS1 DataBar Expanded Code 39 CIP French Pharmaceutical GS1 DataBar Limited CODE 128on page 121 CODE 93on page 183 GS1 128 on page 191 CODE ISBT 128on page 132 PLESSEY on page 198 Default settings are indicated for each feature option with a green arrow Also reference Appendix B Standard Defaults for a listing of the most widely used set of standard factory settings That section also provides space...

Page 80: ...bort and not save the entry string You can then start again at the begin ning 4 Complete the programming sequence by scanning the ENTER EXIT PROGRAM MING barcode to exit Programming Mode DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies 1 Scan the ENTER EXIT PROGRAMMING barcode below 2 Scan the Disable All Symbologies barcode 3 Complete the programming sequence by scanning the EN...

Page 81: ...ODE EAN UPC Coupon Control This feature is used to control the reader s method of processing coupon labels Coupon Control Allow all coupon barcodes to be decoded Coupon Control Enable only UPCA coupon decoding DEFAULT Coupon Control Enable only GS1 DataBar coupon decoding ...

Page 82: ...ology UPC A Enable Disable When disabled the reader will not read UPC A barcodes UPC A Disable UPC A Enable DEFAULT UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A barcode data UPC A Check Character Transmission Don t Send UPC A Check Character Transmission Send DEFAULT ...

Page 83: ...g this feature also changes the symbology ID to match those required for EAN 13 DEFAULT UPC A to EAN 13 Don t Expand UPC A to EAN 13 Expand UPC A Number System Character Transmission This feature enables disables transmission of the UPC A number system character UPC A Number System Character Do not transmit UPC A Number System Character Transmit DEFAULT ...

Page 84: ...170 GFS4150 9 UPC A Minimum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as a good read DEFAULT UPC A Minimum Reads 1 UPC A Minimum Reads 2 UPC A Minimum Reads 3 UPC A Minimum Reads 4 ...

Page 85: ...mbology UPC E Enable Disable When disabled the reader will not read UPC E barcodes UPC E Disable UPC E Enable DEFAULT UPC E Check Character Transmission Enable this option to transmit the check character along with UPC E barcode data UPC E Check Character Transmission Don t Send UPC E Check Character Transmission Send DEFAULT ...

Page 86: ... data to the EAN 13 data format Selecting this feature also changes the symbology ID to match those required for EAN 13 DEFAULT UPC E to EAN 13 Don t Expand UPC E to EAN 13 Expand Expand UPC E to UPC A Expands UPC E data to the UPC A data format DEFAULT UPC E to UPC A Don t Expand UPC E to UPC A Expand ...

Page 87: ...ransmission of the UPC E system number character UPC E Number System Character Do not transmit UPC E Number System Character Transmit DEFAULT UPC E Minimum Reads Specifies the minimum number of consecutive times a UPC E label must be decoded before it is accepted as a good read UPC E Minimum Reads 1 UPC E Minimum Reads 2 DEFAULT UPC E Minimum Reads 3 UPC E Minimum Reads 4 ...

Page 88: ...disables the ability to convert UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character format DEFAULT GTIN Formatting Disable GTIN Formatting Enable If add on information is present on the base label prior to the con version taking place the add on information will be appended to the converted GTIN label ...

Page 89: ...ymbology EAN 13 Enable Disable When disabled the reader will not read EAN 13 JAN 13 barcodes EAN 13 Disable EAN 13 Enable DEFAULT EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data EAN 13 Check Character Transmission Don t Send EAN 13 Check Character Transmission Send DEFAULT ...

Page 90: ...ag1 character The Flag 1 character is the first character of the label EAN 13 Flag 1 Char Don t transmit EAN 13 Flag 1 Char Transmit DEFAULT EAN 13 ISBN Conversion This option enables disables conversion of EAN 13 JAN 13 Bookland labels starting with 978 to ISBN labels DEFAULT EAN 13 ISBN Conversion Disable EAN 13 ISBN Conversion Convert to ISBN ...

Page 91: ...ence Guide 89 EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read DEFAULT EAN 13 Minimum Reads 1 EAN 13 Minimum Reads 2 EAN 13 Minimum Reads 3 EAN 13 Minimum Reads 4 ...

Page 92: ...DE 90 Gryphon I GFS4170 GFS4150 9 ISSN The following options apply to the ISSN symbology ISSN Enable Disable Enables disables conversion of EAN JAN13 Bookland labels starting with 977 to ISSN labels DEFAULT ISSN Disable ISSN Enable ...

Page 93: ... symbology EAN 8 Enable Disable When disabled the reader will not read EAN 8 JAN 8 barcodes EAN 8 Disable EAN 8 Enable DEFAULT EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 barcode data EAN 8 Check Character Transmission Don t Send EAN 8 Check Character Transmission Send DEFAULT ...

Page 94: ...els to EAN 13 JAN 13 DEFAULT Expand EAN 8 to EAN 13 Disable Expand EAN 8 to EAN 13 Enable EAN 8 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 Jan 8 label must be decoded before it is accepted as good read DEFAULT EAN 8 Minimum Reads 1 EAN 8 Minimum Reads 2 EAN 8 Minimum Reads 3 EAN 8 Minimum Reads 4 ...

Page 95: ...therwise marked for each feature description UPC EAN Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See page 255 for more information on this feature UPC EAN Decoding Level 1 Conservative DEFAULT UPC EAN Decoding Level 2 UPC EAN Decoding Level 3 UPC EAN Decoding Level 4 UPC EAN D...

Page 96: ...rrelation will also increase the chances that a label will be read incorrectly DEFAULT UPC EAN Correlation Disable UPC EAN Correlation Enable UPC EAN Price Weight Check This feature enables disables calculation and verification of price weight check digits DEFAULT Price Weight Check Disabled Price Weight Check 4 digit price weight check Price Weight Check 5 digit price weight check Price Weight Ch...

Page 97: ...ore label must be decoded before it is accepted as good read In store labels are defined as UPC A labels with a number system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the three characters 980 In Store Minimum Reads 1 In Store Minimum Reads 2 DEFAULT In Store Minimum Reads 3 In Store Minimum Reads 4 ...

Page 98: ...Disable P2 Optional Add Ons Enable P2 DEFAULT Optional Add Ons Disable P5 Optional Add Ons Enable P5 DEFAULT Optional Add Ons Disable GS1 128 Optional Add Ons Enable GS1 128 If a UPC EAN base label and an add on are both decoded the reader will transmit the base label and add on If a UPC EAN base label is decoded without an add on the base label will be transmitted without an add on Conditional ad...

Page 99: ...ion sets the time the reader will look for an add on when an add on fragment has been seen and optional add ons are enabled Also see Optional GS1 128 Add On Timer on page 100 Optional Add on Timer 10ms Optional Add on Timer 20ms Optional Add on Timer 30ms Optional Add on Timer 40ms Optional Add on Timer 50ms ...

Page 100: ...al Add on Timer 70ms DEFAULT Optional Add on Timer 100ms Optional Add on Timer 120ms Optional Add on Timer 140ms Optional Add on Timer 160ms Add Ons ENTER EXIT PROGRAMMING MODE 98 Gryphon I GFS4170 GFS4150 9 Optional Add On Timer cont ...

Page 101: ... 200ms Optional Add on Timer 220ms Optional Add on Timer 240ms Optional Add on Timer 260ms Optional Add on Timer 280ms Optional Add on Timer 300ms ENTER EXIT PROGRAMMING MODE Optional Add On Timer Product Reference Guide 99 Optional Add On Timer cont ...

Page 102: ...added part after reading the linear EAN UPC part For UPC EAN add ons other than those of that type see Optional Add On Timer on page 97 DEFAULT Optional GS1 128 Add On Timer Disable Optional GS1 128 Add On Timer 10ms Optional GS1 128 Add On Timer 20ms Optional GS1 128 Add On Timer 30ms Optional GS1 128 Add On Timer 40ms Optional GS1 128 Add On Timer 50ms ...

Page 103: ...0ms Optional GS1 128 Add On Timer 100ms Optional GS1 128 Add On Timer 120ms Optional GS1 128 Add On Timer 140ms Optional GS1 128 Add On Timer 160ms ENTER EXIT PROGRAMMING MODE Optional GS1 128 Add On Timer Product Reference Guide 101 Optional GS1 128 Add On Timer cont ...

Page 104: ...onal GS1 128 Add On Timer 220ms Optional GS1 128 Add On Timer 240ms Optional GS1 128 Add On Timer 260ms Optional GS1 128 Add On Timer 280ms Optional GS1 128 Add On Timer 300ms Add Ons ENTER EXIT PROGRAMMING MODE 102 Gryphon I GFS4170 GFS4150 9 Optional GS1 128 Add On Timer cont ...

Page 105: ... P2 Add Ons Minimum Reads This feature specifies the minimum number of times a P2 add on must be read before it is marked as valid and then combined with a base label P2 Add Ons Minimum Reads 1 P2 Add Ons Minimum Reads 2 DEFAULT P2 Add Ons Minimum Reads 3 P2 Add Ons Minimum Reads 4 ...

Page 106: ... Ons Minimum Reads This feature specifies the minimum number of times a P5 add on must be read before it is marked as valid and then combined with a base label DEFAULT P5 Add Ons Minimum Reads 1 P5 Add Ons Minimum Reads 2 P5 Add Ons Minimum Reads 3 P5 Add Ons Minimum Reads 4 ...

Page 107: ...Ons Minimum Reads This feature specifies the minimum number of times an GS1 128 add on must be read before it is marked as valid and then combined with a base label DEFAULT GS1 128 Add Ons Minimum Reads 1 GS1 128 Add Ons Minimum Reads 2 GS1 128 Add Ons Minimum Reads 3 GS1 128 Add Ons Minimum Reads 4 ...

Page 108: ...ode 39 Check Character Calculation Enable this option to enables disables calculation and verification of an optional Code 39 check character When disabled any check character in the label is treated as a data character DEFAULT Code 39 Check Character Calculation Don t Calculate Code 39 Check Character Calculation Calculate Std Check Code 39 Check Character Calculation Calculate Mod 7 Check ...

Page 109: ...is option to transmit the check character along with Code 39 barcode data Code 39 Check Character Transmission Don t Send Code 39 Check Character Transmission Send DEFAULT Code 39 Check Character Calculation cont Code 39 Check Character Calculation Enable Italian Post Check Code 39 Check Character Calculation Enable Daimler Chrysler Check ...

Page 110: ...disable transmission of Code 39 start and stop characters DEFAULT Code 39 Start Stop Character Transmission Don t Transmit Code 39 Start Stop Character Transmission Transmit Code 39 Full ASCII Enables disables the translation of Code 39 characters to Code 39 full ASCII characters DEFAULT Code 39 Full ASCII Disable Code 39 Full ASCII Enable ...

Page 111: ... labels Quiet zones are blank areas at the ends of a barcode typically 10 times the width of the narrowest bar or space in the label Code 39 Quiet Zones Quiet Zone on one side Code 39 Quiet Zones Quiet Zones on two sides Code 39 Quiet Zones Auto DEFAULT Code 39 Quiet Zones Virtual Quiet Zones on two sides Code 39 Quiet Zones Small Quiet Zones on two sides ...

Page 112: ...4150 9 Code 39 Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read Code 39 Minimum Reads 1 Code 39 Minimum Reads 2 DEFAULT Code 39 Minimum Reads 3 Code 39 Minimum Reads 4 ...

Page 113: ...gy decoder to be very aggressive to very conservative depending on a particular customer s needs See page 255 for more information on this feature Code 39 Decoding Level 1 Conservative Code 39 Decoding Level 2 Code 39 Decoding Level 3 DEFAULT Code 39 Decoding Level 4 Code 39 Decoding Level 5 Aggressive This configuration item applies to Code 39 and Code 32 ...

Page 114: ...her variable length decoding or fixed length decoding for the Code 39 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DEFAULT Code 39 Length Control Variable Length Code 39 Length Control Fixed Length ...

Page 115: ... ACTION EXAMPLES 1 Desired Setting 00 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 39 LENGTH 1 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 0 0 and 7 1 and 5 5 AND 0 5 Scan ENTER EXIT PROGRAMMING MODE Select Code 39 Set Length 1 Setting Toconfigure this feature scanthe ENTER EXIT PROGRAMMING MODE barcode above then the bar...

Page 116: ...s examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 3 Code 39 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 39 LENGTH 2 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 0 0 and 7 1 and 5 5 AND 0 5 Scan EN...

Page 117: ...9 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels Code 39 Interdigit Ratio Disable Code 39 Interdigit Ratio 1 Code 39 Interdigit Ratio 2 Code 39 Interdigit Ratio 3 DEFAULT Code 39 Interdigit Ratio 4 Code 39 Interdigit Ratio 5 ...

Page 118: ...IT PROGRAMMING MODE 116 Gryphon I GFS4170 GFS4150 9 Code 39 Interdigit Ratio cont Code 39 Interdigit Ratio 6 Code 39 Interdigit Ratio 7 Code 39 Interdigit Ratio 8 Code 39 Interdigit Ratio 9 Code 39 Interdigit Ratio 10 ...

Page 119: ...ave damaged areas Enabling correlation will also increase the chances that a label will be read incorrectly DEFAULT Code 39 Character Correlation Disable Code 39 Character Correlation Enable Code 39 Stitching This option enables disables stitching for Code 39 labels When parts of a Code 39 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the read...

Page 120: ... Disable When disabled the reader will not read Code 32 barcodes DEFAULT Code 32 Disable Code 32 Enable Code 32 Feature Setting Exceptions The following features are set for Code 32 by using these Code 39 settings Code 39 Quiet Zones on page 109 Code 39 Minimum Reads on page 110 Code 39 Decoding Level on page 111 Code 39 Interdigit Ratio on page 115 Code 39 Character Correlation on page 117 Code 3...

Page 121: ...er along with Code 32 barcode data DEFAULT Code 32 Check Character Transmission Don t Send Code 32 Check Character Transmission Send Code 32 Start Stop Character Transmission This option enables disables transmission of Code 32 start and stop characters DEFAULT Code 32 Start Stop Character Transmission Don t Transmit Code 32 Start Stop Character Transmission Transmit ...

Page 122: ...120 Gryphon I GFS4170 GFS4150 9 CODE 39 CIP FRENCH PHARMACEUTICAL The following options apply to the Code 39 CIP symbology Code 39 CIP Enable Disable Enables Disables ability of the reader to decode Code 39 CIP labels DEFAULT Code 39 CIP Disable Code 39 CIP Enable ...

Page 123: ...to the Code 128 symbology Code 128 Enable Disable When disabled the reader will not read Code 128 barcodes Code 128 Disable Code 128 Enable DEFAULT Expand Code 128 to Code 39 This feature enables disables expansion of Code 128 labels to Code 39 labels DEFAULT Code 128 to Code 39 Don t Expand Code 128 to Code 39 Expand ...

Page 124: ...ter along with Code 128 barcode data DEFAULT Code 128 Check Character Transmission Don t Send Code 128 Check Character Transmission Send Code 128 Function Character Transmission Enables disables transmission of Code128 function characters 1 2 3 and 4 DEFAULT Code 128 Function Character Transmission Don t Send Code 128 Function Character Transmission Send ...

Page 125: ...Product Reference Guide 123 Code 128 Sub Code Change Transmission Enables disables the transmission of Sub Code exchange characters NOT transmitted by standard decoding DEFAULT Code 128 Sub Code Change Transmission Disable Code 128 Sub Code Change Transmission Enable ...

Page 126: ...labels Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label Code 128 Quiet Zones No Quiet Zones Code 128 Quiet Zones Quiet Zone on one side Code 128 Quiet Zones Quiet Zones on two sides Code 128 Quiet Zones Auto DEFAULT Code 128 Quiet Zones Virtual Quiet Zones on two sides ...

Page 127: ...Guide 125 Code 128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read DEFAULT Code 128 Minimum Reads 1 Code 128 Minimum Reads 2 Code 128 Minimum Reads 3 Code 128 Minimum Reads 4 ...

Page 128: ...ure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See page 255 for more information on this feature Code 128 Decoding Level 1 Conservative Code 128 Decoding Level 2 Code 128 Decoding Level 3 DEFAULT Code 128 Decoding Level 4 Code 128 Decoding Level 5 Aggressive ...

Page 129: ...rence Guide 127 Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology See page 256 for more information DEFAULT Code 128 Length Control Variable Length Code 128 Length Control Fixed Length ...

Page 130: ...setting Length 1 See page 256 for detailed instructions on setting this feature Table 4 Code 128 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 15 Characters 80 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 128 LENGTH 1 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 1 0 and 7 1 and 5 8 AND 0 5 Scan ENTER EXIT PROGRAMMING M...

Page 131: ...ed length Table 5 provides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 5 Code 128 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 80 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 128 LENGTH 2 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 0 0 and ...

Page 132: ... areas Enabling correlation will also increase the chances that a label will be read incorrectly DEFAULT Code 128 Character Correlation Disable Code 128 Character Correlation Enable Code 128 Stitching This option enables disables stitching for Code 128 labels When parts of a Code 128 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s s...

Page 133: ...S1 128 Enable This option enables disables the ability of the reader to translate GS1 128 labels to the GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not transmit GS1 128 labels DEFAULT GS1 128 Transmit in Code 128 data format GS1 128 Transmit in GS1 128 data format GS1 128 Do not transmit GS1 128 labels ...

Page 134: ...s option to enable disable ISBT128 concatenation of 2 labels DEFAULT ISBN 128 Concatenation Disable ISBN 128 Concatenation Enable ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic DEFAULT ISBT 128 Concatenation Mode Static ISBT 128 Concatenation Mode Dynamic This option is only valid when ISBT 128 Concatenation is enabled see page 132 ...

Page 135: ... ISBT 128 Dynamic Concatenation Timeout 100 msec DEFAULT ISBT 128 Dynamic Concatenation Timeout 200 msec ISBT 128 Dynamic Concatenation Timeout 500 msec ISBT 128 Dynamic Concatenation Timeout 750 msec ISBT 128 Dynamic Concatenation Timeout 1 second ISBT 128 Advanced Concatenation Options To set up pairs of label types for concatenation use the Datalogic Aladdin configuration application or contact...

Page 136: ... disabled the reader will not read I 2 of 5 barcodes DEFAULT I 2 of 5 Disable I 2 of 5 Enable I 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional I 2 of 5 check character DEFAULT I 2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Calculation Check Standard Modulo 10 I 2 of 5 Check Character Calculation Check German Parcel...

Page 137: ...r along with I 2 of 5 barcode data I 2 of 5 Check Character Transmission Don t Send I 2 of 5 Check Character Transmission Send DEFAULT I 2 of 5 Check Character Calculation cont I 2 of 5 Check Character Calculation Check DHL I 2 of 5 Check Character Calculation Check Daimler Chrysler I 2 of 5 Check Character Calculation Check Bosch I 2 of 5 Check Character Calculation Italian Post ...

Page 138: ...170 GFS4150 9 I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read DEFAULT I 2 of 5 Minimum Reads 1 I 2 of 5 Minimum Reads 2 I 2 of 5 Minimum Reads 3 I 2 of 5 Minimum Reads 4 ...

Page 139: ...and Standard 2 of 5 Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See page 255 for more information on this feature 2 of 5 Decoding Level 1 Conservative 2 of 5 Decoding Level 2 2 of 5 Decoding Level 3 DEFAULT 2 of 5 Decoding Level 4 2 of 5 Decoding Level 5 Aggressive ...

Page 140: ...ifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DEFAULT I 2 of 5 Length Control Variable Length I 2 of 5 Length Control Fixed Length ...

Page 141: ...etting Length 1 See page 256 for detailed instructions on setting this feature Table 6 I 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 02 06 14 50 3 Scan ENTER EXIT PROGRAMMING MODE 4 Scan SELECT I 2 of 5 LENGTH 1 SETTING 5 Scan Two Characters From Appendix D Keypad 0 and 2...

Page 142: ... provides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 7 I 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore This Length 4 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 00 04 14 50 3 Scan ENTER EXIT PROGRAMMING MODE 4 Scan SELECT I 2 OF 5 LENGTH 2 SETTING 5 Scan Two Characters ...

Page 143: ...e damaged areas Enabling correlation will also increase the chances that a label will be read incorrectly DEFAULT I 2 of 5 Character Correlation Disable I 2 of 5 Character Correlation Enable I 2 of 5 Stitching This option enables disables stitching for I 2 of 5 labels When parts of a I 2 of 5 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the r...

Page 144: ...ble When disabled the reader will not read Standard 2 of 5 barcodes DEFAULT Standard 2 of 5 Disable Standard 2 of 5 Enable Standard 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional Standard 2 of 5 check character DEFAULT Standard 2 of 5 Check Character Calculation Disable Standard 2 of 5 Check Character Calculation Enable ...

Page 145: ...character Standard 2 of 5 Check Character Transmission Don t Send Standard 2 of 5 Check Character Transmission Send DEFAULT Standard 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read Standard 2 of 5 Minimum Reads 1 Standard 2 of 5 Minimum Reads 2 DEFAULT Standard 2 of 5 Minimum Reads 3 Stan...

Page 146: ...tandard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DEFAULT Standard 2 of 5 Length Control Variable Length Standard 2 of 5 Length Control Fixed Length ...

Page 147: ...amples for setting Length 1 See page 256 if you want detailed instructions on setting this feature Table 8 Standard 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 1 0 and 7 1 and 5 5 AND ...

Page 148: ...ble 9 provides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 9 Standard 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 DesiredSetting padwithleading zeroes 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING 4 Scan Two Characters From Appendix ...

Page 149: ...abling correlation will also increase the chances that a label will be read incorrectly DEFAULT Standard 2 of 5 Character Correlation Disable Standard 2 of 5 Character Correlation Enable Standard 2 of 5 Stitching This option enables disables stitching for Standard 2 of 5 labels When parts of a Standard 2 of 5 barcode are presented to the reader with this feature enabled the barcode parts will be a...

Page 150: ...able Enables Disables ability of reader to decode Industrial 2 of 5 labels DEFAULT Industrial 2 of 5 Disable Industrial 2 of 5 Enable Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verification of an optional Industrial 2 of 5 check character DEFAULT Industrial 2 of 5 Check Character Calculation Disable Industrial 2 of 5 Check Character Calculation Enable ...

Page 151: ...on Disable Industrial 2 of 5 Check Character Transmission Enable DEFAULT Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DEFAULT Industrial 2 ...

Page 152: ...or setting Length 1 See page 256 if you want detailed instructions on setting this feature Table 10 Industrial 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 1 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 0 0 and 7 1 and 5 5 AND 0 ...

Page 153: ...s to ignore this length only one fixed length Table 11 provides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 11 Industrial 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING 4 S...

Page 154: ...l must be decoded before it is accepted as good read DEFAULT Industrial 2 of 5 Minimum Reads 1 Industrial 2 of 5 Minimum Reads 2 Industrial 2 of 5 Minimum Reads 3 Industrial 2 of 5 Minimum Reads 4 Industrial 2 of 5 Character Correlation Enable disables character correlation for Industrial 2 of 5 DEFAULT Industrial 2 of 5 Character Correlation Disable Industrial 2 of 5 Character Correlation Enable ...

Page 155: ...DE Industrial 2 of 5 Stitching Product Reference Guide 153 Industrial 2 of 5 Stitching Enables disables fixed length stitching for Industrial 2 of 5 DEFAULT Industrial 2 of 5 Stitching Disable Industrial 2 of 5 Stitching Enable ...

Page 156: ...A Enable Disable Enables Disables the ability of the reader to decode IATA labels DEFAULT IATA Disable IATA Enable IATA Check Character Transmission Enables Disables calculation and verification of an optional Industrial 2 of 5 check character IATA Check Character Transmission Disable IATA Check Character Transmission Enable DEFAULT ...

Page 157: ...Disable When disabled the reader will not read Datalogic 2 of 5 barcodes DEFAULT Datalogic 2 of 5 Disable Datalogic 2 of 5 Enable Datalogic 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional Datalogic 2 of 5 check character DEFAULT Datalogic 2 of 5 Check Character Calculation Disable Datalogic 2 of 5 Check Character Calculation Enable ...

Page 158: ...imum number of consecutive times an Datalogic 2 of 5 label must be decoded before it is accepted as good read I 2 of 5 Minimum Reads 1 I 2 of 5 Minimum Reads 2 DEFAULT I 2 of 5 Minimum Reads 3 I 2 of 5 Minimum Reads 4 Datalogic 2 of 5 Decoding Level The Datalogic 2 of 5 Decoding Level feature is set using 2 of 5 Decoding Level on page 137 ...

Page 159: ...ther variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DEFAULT Datalogic 2 of 5 Length Control Variable Length Datalogic 2 of 5 Length Control Fixed Length ...

Page 160: ...ng Length 1 See page 256 for detailed instructions on setting this feature Table 12 Datalogic 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 02 06 14 50 3 Scan ENTER EXIT PROGRAMMING MODE 4 Scan SELECT Datalogic 2 of 5 LENGTH 1 SETTING 5 Scan Two Characters From Appendix D K...

Page 161: ...ides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 13 Datalogic 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore This Length 4 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 00 04 14 50 3 Scan ENTER EXIT PROGRAMMING MODE 4 Scan SELECT DATALOGIC 2 OF 5 LENGTH 2 SETTING 5 Scan Two...

Page 162: ...ing correlation will also increase the chances that a label will be read incorrectly DEFAULT I 2 of 5 Character Correlation Disable I 2 of 5 Character Correlation Enable Datalogic 2 of 5 Stitching This option enables disables stitching for Datalogic 2 of 5 labels When parts of a Datalogic 2 of 5 barcode are presented to the reader with this feature enabled the barcode parts will be assembled by th...

Page 163: ... Disable Codabar Enable Codabar Check Character Calculation Enable this option to enables disables calculation and verification of an optional Codabar check character When disabled any check character in the label is treated as a data character DEFAULT Codabar Check Character Calculation Don t Calculate Codabar Check Character Calculation Enable AIM standard check char Codabar Check Character Calc...

Page 164: ...th Codabar barcode data Codabar Check Character Transmission Don t Send Codabar Check Character Transmission Send DEFAULT Codabar Start Stop Character Transmission Enable this option to enable disable transmission of Codabar start and stop characters Codabar Start Stop Character Transmission Don t Transmit Codabar Start Stop Character Transmission Transmit DEFAULT ...

Page 165: ... characters Codabar Check Character Set ABCD TN E Codabar Check Character Set ABCD ABCD Codabar Check Character Set abcd tn e Codabar Check Character Set abcd abcd DEFAULT Codabar Start Stop Character Match When enabled this option requires that start and stop characters match DEFAULT Codabar Start Stop Character Match Don t Require Match Codabar Start Stop Character Match Require Match ...

Page 166: ...zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label Codabar Quiet Zones Quiet Zone on one side Codabar Quiet Zones Quiet Zones on two sides Codabar Quiet Zones Auto DEFAULT Codabar Quiet Zones Virtual Quiet Zones on two sides Codabar Quiet Zones Small Quiet Zones on two sides ...

Page 167: ...e Guide 165 Codabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read DEFAULT Codabar Minimum Reads 1 Codabar Minimum Reads 2 Codabar Minimum Reads 3 Codabar Minimum Reads 4 ...

Page 168: ... configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See page 255 for more information on this feature Codabar Decoding Level 1 Conservative Codabar Decoding Level 2 Codabar Decoding Level 3 DEFAULT Codabar Decoding Level 4 Codabar Decoding Level 5 ...

Page 169: ...s either variable length decoding or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DEFAULT Codabar Length Control Variable Length Codabar Length Control Fixed Length ...

Page 170: ... provides some examples for setting Length 1 See page 256 for detailed instructions on setting this feature Table 14 Codabar Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting and pad with leading zeroes 03 Characters 09 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODABAR LENGTH 1 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 3...

Page 171: ...s length only one fixed length Table 15 provides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 15 Codabar Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting and pad with leading zeroes 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODABAR LENGTH 2 SETTING 4 Scan Two...

Page 172: ...digit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels Codabar Interdigit Ratio Disable Codabar Interdigit Ratio 1 Codabar Interdigit Ratio 2 Codabar Interdigit Ratio 3 DEFAULT Codabar Interdigit Ratio 4 Codabar Interdigit Ratio 5 ...

Page 173: ... MODE Codabar Interdigit Ratio Product Reference Guide 171 Codabar Interdigit Ratio cont Codabar Interdigit Ratio 6 Codabar Interdigit Ratio 7 Codabar Interdigit Ratio 8 Codabar Interdigit Ratio 9 Codabar Interdigit Ratio 10 ...

Page 174: ...ed areas Enabling correlation will also increase the chances that a label will be read incorrectly DEFAULT Codabar Character Correlation Disable Codabar Character Correlation Enable Codabar Stitching This option enables disables stitching for Codabar labels When parts of a Codabar barcode are presented to the reader with this feature enabled the barcode parts will be assembled by the reader s soft...

Page 175: ...C Codabar symbology ABC Codabar Enable Disable Enables Disables ability of reader to decode ABC Codabar labels DEFAULT ABC Codabar Disable ABC Codabar Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic DEFAULT ABC Codabar Concatenation Mode Static ABC Codabar Concatenation Mode Dynamic ...

Page 176: ...sed by the ABC Codabar Dynamic Concatenation Mode ABC Codabar Dynamic Concatenation Timeout 50 msec ABC Codabar Dynamic Concatenation Timeout 100 msec DEFAULT ABC Codabar Dynamic Concatenation Timeout 200 msec ABC Codabar Dynamic Concatenation Timeout 500 msec ABC Codabar Dynamic Concatenation Timeout 750 msec ABC Codabar Dynamic Concatenation Timeout 1 Second ...

Page 177: ...tional Enable Disable When disabled the reader will not read GS1 DataBar Omnidirectional barcodes DEFAULT GS1 DataBar Omnidirectional Disable GS1 DataBar Omnidirectional Enable GS1 DataBar Omnidirectional GS1 128 Emulation When enabled GS1 DataBar Omnidirectional barcodes will be translated to the GS1 128 label data format DEFAULT GS1 DataBar Omnidirectional GS1 128 Emulation Disable GS1 DataBar O...

Page 178: ...his feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirectional label must be decoded before it is accepted as good read DEFAULT GS1 DataBar Omnidirectional Minimum Reads 1 GS1 DataBar Omnidirectional Minimum Reads 2 GS1 DataBar Omnidirectional Minimum Reads 3 GS1 DataBar Omnidirectional Minimum Reads 4 ...

Page 179: ...S1 DataBar Expanded Enable Disable When disabled the reader will not read GS1 DataBar Expanded barcodes DEFAULT GS1 DataBar Expanded Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 128 Emulation When enabled GS1 DataBar Expanded barcodes will be translated to the GS1 128 label data format DEFAULT GS1 DataBar Expanded GS1 128 Emulation Disable GS1 DataBar Expanded GS1 128 Emulation Ena...

Page 180: ...aBar Expanded Minimum Reads 2 GS1 DataBar Expanded Minimum Reads 3 GS1 DataBar Expanded Minimum Reads 4 GS1 DataBar Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be ...

Page 181: ...xamples for setting Length 1 See page 256 for detailed instructions on setting this feature Table 16 GS1 DataBar Expanded Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 52 Characters 74 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT GS1 DataBar EXPANDED LENGTH 1SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 1 0 and 7 5 and 2 7 A...

Page 182: ...h Table 17 provides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 17 GS1 DataBar Expanded Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 ignoresecond length 07 Characters 52 Characters 74 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING 4 Scan Two Characters From Appendix D Ke...

Page 183: ... GS1 DataBar Limited Enable Disable When disabled the reader will not read GS1 DataBar Limited barcodes DEFAULT GS1 DataBar Limited Disable GS1 DataBar Limited Enable GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataBar Limited barcodes will be translated to the GS1 128 label data format DEFAULT GS1 DataBar Limited GS1 128 Emulation Disable GS1 DataBar Limited GS1 128 Emulation Enable ...

Page 184: ...imum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read DEFAULT GS1 DataBar Limited Minimum Reads 1 GS1 DataBar Limited Minimum Reads 2 GS1 DataBar Limited Minimum Reads 3 GS1 DataBar Limited Minimum Reads 4 ...

Page 185: ...r to decode Code 93 labels DEFAULT Code 93 Disable Code 93 Enable Code 93 Check Character Calculation Enables disables calculation and verification of an optional Code 93 check character Code 93 Check Character Calculation Disable Code 93 Check Character Calculation Enable Check C Code 93 Check Character Calculation Enable Check K Code 93 Check Character Calculation Enable Check C and K DEFAULT ...

Page 186: ...Disable Code 93 Check Character Transmission Enable DEFAULT Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DEFAULT Code 93 Length Control Variable Length Code 93...

Page 187: ... for setting Length 1 See page 256 for detailed instructions on setting this feature Table 18 Code 93 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 93 LENGTH 1 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 1 0 and 7 1 and 5 5 AND 0 5 Scan ENTER EXIT PROGRAMM...

Page 188: ...ignore this length only one fixed length Table 19 provides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 19 CODE 93 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 93 LENGTH 2 SETTING 4 Scan Two Characters From A...

Page 189: ...e Guide 187 Code 93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read DEFAULT Code 93 Minimum Reads 1 Code 93 Minimum Reads 2 Code 93 Minimum Reads 3 Code 93 Minimum Reads 4 ...

Page 190: ...configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See page 255 for more information on this feature Code 93 Decoding Level Disable Code 93 Decoding Level 1 Conservative Code 93 Decoding Level 2 Code 93 Decoding Level 3 DEFAULT Code 93 Decoding Level 4 Code 93 Decoding Level 5 Aggressive ...

Page 191: ...189 Code 93 Quiet Zones Enables disables quiet zones for Code 93 Code 93 Quiet Zones No Quiet Zones Code 93 Quiet Zones Quiet Zone on one side Code 93 Quiet Zones Quiet Zones on two sides Code 93 Quiet Zones Auto DEFAULT Code 93 Quiet Zones Virtual Quiet Zones on two sides ...

Page 192: ...r Correlation Enables disables Character Correlation for Code 93 Code 93 Character Correlation Disable Code 93 Character Correlation Enable DEFAULT Code 93 Stitching Disable enable fixed or variable length stitching for Code 93 Code 93 Stitching Disable Code 93 Stitching Enable DEFAULT ...

Page 193: ...lity of reader to decode MSI labels DEFAULT MSI Disable MSI Enable MSI Check Character Calculation Enables Disables calculation and verification of an optional MSI check character MSI Check Character Calculation Disable MSI Check Character Calculation Enable Mod10 DEFAULT MSI Check Character Calculation Enable Mod11 10 MSI Check Character Calculation Enable Mod10 10 ...

Page 194: ...able MSI Check Character Transmission Enable DEFAULT MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DEFAULT MSI Length Control Variable Length MSI Fixed Length ...

Page 195: ...amples for setting Length 1 See page 256 for detailed instructions on setting this feature Table 20 MSI Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT MSI LENGTH 1 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 1 0 and 7 1 and 5 5 AND 0 5 Scan ENTER EXIT PROGRAMMIN...

Page 196: ...ignore this length only one fixed length Table 21 provides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 21 MSI Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT MSI LENGTH 2 SETTING 4 Scan Two Characters From Appendix ...

Page 197: ...t Reference Guide 195 MSI Minimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read MSI Minimum Reads 1 MSI Minimum Reads 2 MSI Minimum Reads 3 MSI Minimum Reads 4 DEFAULT ...

Page 198: ...ed to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See page 255 for more information on this feature MSI Decoding Level Disable MSI Decoding Level 1 conservative MSI Decoding Level 2 MSI Decoding Level 3 DEFAULT MSI Decoding Level 4 MSI Decoding Level 5 aggressive ...

Page 199: ...e 197 MSI Stitching Enables disables fixed length stitching for MSI DEFAULT MSI Stitching Disable MSI Stitching Enable MSI Character Correlation Enables disables Character Correlation for MSI DEFAULT MSI Character Correlation Disable MSI Character Correlation Enable ...

Page 200: ...AMMING MODE 198 Gryphon I GFS4170 GFS4150 9 PLESSEY The following options apply to the Plessey symbology Plessey Enable Disable Enables Disables ability of reader to decode Plessey labels DEFAULT Plessey Disable Plessey Enable ...

Page 201: ...n Disable Plessey Check Character Calculation Enable Plessey std check char verification DEFAULT Plessey Check Character Calculation Enable Anker check char verification Plessey Check Character Calculation Enable Plessey std and Anker check char verification Plessey Check Character Transmission Enables disables transmission of an MSI check character Plessey Check Character Transmission Disable Ple...

Page 202: ...ies either variable length decoding or fixed length decoding for the Plessey symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DEFAULT Plessey Length Control Variable Length Plessey Fixed Length ...

Page 203: ...xamples for setting Length 1 See page 256 for detailed instructions on setting this feature Table 22 Plessey Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT Plessey LENGTH 1 SETTING 4 Scan Two Characters From Appendix D Keypad 0 and 1 0 and 7 1 and 5 5 AND 0 5 Scan ENTER EXIT P...

Page 204: ...ignore this length only one fixed length Table 23 provides examples for setting Length 2 See page 256 for detailed instructions on setting this feature Table 23 Plessey Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT PLESSEY LENGTH 2 SETTING 4 Scan Two Characters From A...

Page 205: ...e Guide 203 Plessey Minimum Reads This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read Plessey Minimum Reads 1 Plessey Minimum Reads 2 Plessey Minimum Reads 3 Plessey Minimum Reads 4 DEFAULT ...

Page 206: ...configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See page 255 for more information on this feature Plessey Decoding Level Disable Plessey Decoding Level 1 conservative Plessey Decoding Level 2 Plessey Decoding Level 3 DEFAULT Plessey Decoding Level 4 Plessey Decoding Level 5 aggressive ...

Page 207: ...Stitching Enables disables fixed length stitching for Plessey DEFAULT Plessey Stitching Disable Plessey Stitching Enable Plessey Character Correlation Enables disables Character Correlation for Plessey DEFAULT Plessey Character Correlation Disable Plessey Character Correlation Enable ...

Page 208: ...Plessey ENTER EXIT PROGRAMMING MODE 206 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 209: ... restored 2 Using a Terminal Emulation Program send the Restore Current Interface Custom Default string to the reader using the syntax described on the next page 3 Send all the necessary command strings according to your application s requirements To configure USB models only for USB COM Interface by using the configuration strings USB models by default have the USB KBD Interface selected and are ...

Page 210: ...Interface Selection AA Enable All Symbologies AD Disable All Symbologies R Reset Reader CXXXXXX Write Single Configuration Item to RAM Parameter XXXX A 4 character ASCII string See Serial Configuration Strings Table Value XX A 2 character Hex string See Serial Configuration Strings Table 3 Apply and Save Configuration to FLASH permanent memory and Exit Service Mode Ar CR This command automatically...

Page 211: ... Select RS232 Interface 3 Ar CR Apply and Save Configuration to FLASH permanent memory and Exit Service Mode Example 3 1 CR Read Application Software Release Example 4 Some parameters ex Strings need to insert all the characters typically 20 Chrs For example to apply the Chr T 0x54 as Serial Stop String 1 S CR Enter Service Mode 2 CSTON5400000000000000000000000000000000000000 CR Select the string ...

Page 212: ...rary memory Cxxxxxx Read Single Configuration Item from RAM temporary memory cxxxx Reset Reader R Read Application Software Release does not require Enter Exit Service Mode Host Commands Obey CIFIH00 Host Commands Ignore CIFIH01 Enable All Symbologies AA Disable All Symbologies AD The Interface Selection commands store and load the new interface type with its factory defaults into the current conf...

Page 213: ...05 57600 06 115200 07 Parity none R2PA 00 even 01 odd 02 Data Bits 7 R2DA 00 8 01 Stop Bits 1 R2ST 00 2 01 Handshaking Control RTS R2HC 00 RTS CTS R2HC 01 RTS Xon Xoff R2HC 02 RTS On CTS R2HC 03 RTS CTS Scan Control R2HC 04 To read a particular parameter setting from the reader send the read parameter command without any value The reader will respond with its currently configured value The Read Ap...

Page 214: ... e ACK NAK Error Handling Ignore errors detected R2EH 00 Process errors as valid ACK character 01 Process errors as valid NAK character 02 Beep On ASCII BEL Disable R2BB 00 Enable 01 Beep On Not On File Disable BPNF 00 Enable 01 Indicate Transmission Failure Disable R2TF 00 Enable 01 Software Configuration Strings 212 Gryphon I GFS4170 GFS4150 9 a Hex value from 00 to 63 representing the decimal n...

Page 215: ...Germany 05 Hungary 0D Italy 06 Japanese 106 key 0C Norway 07 Poland 12 Portugal 08 Romania 10 Slovakia 0F Spain 09 Sweden 0A Switzerland 0B Send Control Characters CTRL KEY KBSC 00 CTRL SHIFT KEY 01 Special Function KEY 02 USB Keyboard Speed 1 ms KBSP 01 2 ms 02 3 ms 03 4 ms 04 5 ms 05 6 ms 06 7 ms 07 8 ms 08 9 ms 09 10 ms 0A Product Reference Guide 213 Valid for USB KBD APPLE ...

Page 216: ...00 Timeout 01 Trigger Stop Timeout 02 Timeout From 40 to 5100 ms SNET h Serial Start Any string of characters max 20 between 00 FE STON i Serial Stop Any string of characters max 20 between 00 FE STOF i Label Programming Mode Disabled FAPM 00 Enabled 01 Exposure Mode Continuous SPST 00 Strobed SPST 01 Software Configuration Strings 214 Gryphon I GFS4170 GFS4150 9 g Hex value from 02 to FF represen...

Page 217: ...ader Any string of characters max 20 between 00 FE LFPR k Global Suffix Terminator Any string of characters max 20 between 00 FE LFSU k No Read String Any string of characters max 20 between 00 FE NORS k Character Conversion An 8 character string between 00 FF LFCH m Transmit AIM IDs Disable AIEN 00 Enable 01 Transmit Custom Label IDs Disable IDCO 00 Prefix 01 Suffix 02 GS1 128 AIM ID Disable U8AI...

Page 218: ...5 85ID k EAN 13 P2 32ID k EAN 13 P5 35ID k ISBN ISID k ISSN INID k GTIN for EAN UPC w o Add On GBID k GTIN for EAN UPC w P2 G2ID k GTIN for EAN UPC w P5 G5ID k Code 39 C3ID k Code 32 P3ID k Code 128 C8ID k GS1 128 U8ID k ISBT 128 I8ID k Interleaved 2 of 5 I2ID k Standard 2 of 5 S2ID k Industrial 2 of 5 U2ID k Datalogic 2 of 5 D2ID k IATA IAID k Codabar CBID k ABC Codabar ACID k GS1 Databar 14 Omni...

Page 219: ... 00 Good Read 01 No Read 02 Wrong Code 03 Deactivation Event Disable OUD1 00 Timeout 01 Reading Phase Active 02 Deactivation Timeout 100 to 25500 ms OUT1 n Active Level Closed OUL1 00 Open 01 n Hex value from 01 to FF representing the decimal number x100 ms Code 93 C9ID k MSI MSID k Plessey PLID k Custom Code Identifiers Any string of characters max 3 between 00 FE ...

Page 220: ...ead Beep Disable BPVO 00 Enable 01 Good Read Beep Length Time length from 10 to 2550 ms BPLE o Good Read Led Duration Time length from 0 to 25 500 ms LAGL f Green Spot Duration Disable LSSP 00 Short 300ms 01 Medium 500ms 02 Long 800ms 03 Led Indication On Decode BPIN 00 After Transmit 01 Software Configuration Strings 218 Gryphon I GFS4170 GFS4150 9 o Hex value from 01 to FF representing the decim...

Page 221: ... Allow all coupon barcodes to be decoded CPCL 00 Enable only UPC A coupon decoding 01 Enable only GS1 Databar coupon decoding 02 UPC E UPC E Disable EBEN 00 Enable 01 Check Character Tx Disable EBCT 00 Enable 01 Expand to UPC A Disable EBAB 00 Enable 01 Expand to EAN 13 Disable EB3B 00 Enable 01 Number System Tx Disable EBNS 00 Enable 01 Minimum Reads One Read EBMR 01 Two Reads 02 Three Reads 03 F...

Page 222: ...Enable 01 Check Character Tx Disable 8BCT 00 Enable 01 Expand to EAN 13 Disable 8B3B 00 Enable 01 Minimum Reads One Read 8BMR 01 Two Reads 02 Three Reads 03 Four Reads 04 Add Ons P2 Add On Disable ADO2 00 Enable 01 P5 Add On Disable ADO5 00 Enable 01 P2 Minimum Reads One Read ADM2 01 Two Reads 02 Three Reads 03 Four Reads 04 P5 Minimum Reads One Read ADM5 01 Two Reads 02 Three Reads 03 Four Reads ...

Page 223: ... 00 Enable 01 Code Length Control Variable C3LC 00 Fixed 01 Set Length Length 1 or Min Length from 1 to 50 characters C3L1 q Length 2 or Max Length 0 or from 1 to 50 characters C3L2 q Code 32 Italian Pharma Disable P3EN 00 Enable 01 Code 32 Check Tx Disable P3CT 00 Enable 01 Code 32 Start Stop Tx Disable P3SS 00 Enable 01 Check Options Check Calculation Disable C3CC 00 Enable Standard Check 01 Ena...

Page 224: ...o Sides 02 Auto 03 Virtual Quiet Zones on Two Sides 04 Small Quiet Zones on Two Sides 05 Stitching Disable C3ST 00 Enable 01 Code 128 GS1 128 Code 128 Disable C8EN 00 Enable 01 GS1 128 Enable Enable transmit labels in Code 128 data format U8EN 00 Enable transmit labels in GS1 128 data format 01 Disable 02 Code Length Control Variable C8LC 00 Fixed 01 Set Length Length 1 or Min Length from 1 to 80 ...

Page 225: ...l 2 02 Level 3 03 Level 4 04 Level 5 05 Character Correlation Disable C8CO 00 Enable 01 Quiet Zones No Quiet Zones C8LO 00 Quiet Zone on One Side 01 Quiet Zones on Two Sides 02 Auto 03 Virtual Quiet Zones on Two Sides 04 Stitching Disable C8ST 00 Enable 01 ISBT 128 ISBT 128 Concatenation Disable I8CE 00 Enable 01 Concatenation Mode Static I8CM 00 Dynamic 01 Dynamic Concat Timeout From 50 to 2550 m...

Page 226: ... I2CC 00 Enable Standard Mod 10 01 Enable German Parcel 02 Enable DHL 04 Enable Daimler Chrysler 08 Enable Bosch 10 Enable Italian Post 20 Check Tx Disable I2CT 00 Enable 01 Decoding Options Minimum Reads One Read I2MR 01 Two Reads 02 Three Reads 03 Four Reads 04 Decoding Level Disable I2DL 00 Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 Character Correlation Disable I2CO 00 Enable 01 St...

Page 227: ...eads 02 Three Reads 03 Four Reads 04 Decoding Level Disable S2DL 00 Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 Character Correlation Disable S2CO 00 Enable 01 Stitching Disable S2ST 00 Enable 01 Industrial 2 of 5 Industrial 2 of 5 Disable U2EN 00 Enable 01 Code Length Control Variable U2LC 00 Fixed 01 Set Length Length 1 or Min Length from 1 to 50 characters U2L1 v Length 2 or Max Leng...

Page 228: ...talogic 2 of 5 Disable D2EN 00 Enable 01 Code Length Control Variable D2LC 00 Fixed 01 Set Length Length 1 or Min Length from 1 to 50 characters D2L1 v Length 2 or Max Length 0 or from 1 to 50 characters D2L2 v Check Options Check Calculation Disable D2CC 00 Enable 01 Check Tx Disable D2CT 00 Enable 01 Decoding Options Minimum Reads One Read D2MR 01 Two Reads 02 Three Reads 03 Four Reads 04 Decodi...

Page 229: ...tion Mode Static CBCM 00 Dynamic 01 Dynamic Concat Timeout From 50 to 2550 ms CBDT t Check Options Check Calculation Disable CBCC 00 Enable AIM Standard Check 01 Enable Mod 10 Check 02 Check Tx Disable CBCT 00 Enable 01 Start Stop Set ABCD TN E CBSC 00 ABCD ABCD 01 abcd tn e 02 abcd abcd 03 Start Stop Tx Disable CBSS 00 Enable 01 Start Stop Match Disable CBSM 00 Enable 01 Decoding Options Minimum ...

Page 230: ...Zones on Two Sides 05 Stitching Disable CBST 00 Enable 01 GS1 Databar Omnidirectional GS1 Databar Omnidirec tional Disable 4BEN 00 Enable 01 GS1 128 Emulation Disable 4BU8 00 Enable 01 Omnidirectional Decoding Options Minimum Reads One Read 4BMR 01 Two Reads 02 Three Reads 03 Four Reads 04 GS1 Databar Expanded GS1 Databar Expanded Disable XBEN 00 Enable 01 GS1 128 Emulation Disable XBU8 00 Enable ...

Page 231: ...e LBU8 00 Enable 01 Limited Decoding Options Minimum Reads One Read LBMR 01 Two Reads 02 Three Reads 03 Four Reads 04 Code 93 Code 93 Disable C9EN 00 Enable 01 Code Length Control Variable C9LC 00 Fixed 01 Set Length Length 1 or Min Length from 1 to 50 characters C9L1 v Length 2 or Max Length 0 or from 1 to 50 characters C9L2 v Check Options Check Calculation Disable C9CC 00 Enable Check C 01 Enab...

Page 232: ...titching Disable C9ST 00 Enable 01 MSI MSI Disable MSEN 00 Enable 01 Code Length Control Variable MSLC 00 Fixed 01 Set Length Length 1 or Min Length from 1 to 50 characters MSL1 v Length 2 or Max Length 0 or from 1 to 50 characters MSL2 v Check Options Check Calculation Disable MSCC 00 Enable Mod 10 01 Enable Mod 11 10 02 Enable Mod 10 10 03 Check Tx Disable MSCT 00 Enable 01 Decoding Options Mini...

Page 233: ...to 50 characters PLL2 v Check Options Check Calculation Disable PLCC 00 Standard 01 Anker Calculation 02 Standard and Anker Calculation 03 Check Tx Disable PLCT 00 Enable 01 Decoding Options Minimum Reads One Read PLMR 01 Two Reads 02 Three Reads 03 Four Reads 04 Decoding Level Disable PLDL 00 Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 Character Correlation Disable PLCO 00 Enable 01 St...

Page 234: ...Software Configuration Strings 232 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 235: ...e Set the number of stop bits to match host device requirements Parity This feature specifies parity required for sending and receiving data A parity check bit is the most significant bit of each ASCII coded character Select the parity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to e...

Page 236: ... 20 20 etc 3 Scan the ENTER EXIT PROGRAMMING MODE barcode to enter Programming Mode 4 Go to page 27 and scan the barcode SELECT INTERCHARACTER DELAY SET TING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character If you make a mistake before the last cha...

Page 237: ...defined characters such as XON XOFF or host com mands conflicts with normal operation of these characters 8 bit data is not recognized when the option Data Bits has been set as 7 Data Bits 1 Determine the desired character or value Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character value 2 Go to page 29 and scan ENTER EXIT PROGRAMMING M...

Page 238: ...e 29 and scan the ENTER EXIT PROGRAMMING MODE barcode to enter Programming Mode 4 Scan the barcode SELECT NAK CHARACTER SETTING 5 Scan the appropriate two alpha numeric characters from the keypad in Appendix D Key pad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mo...

Page 239: ... SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character If you make a mistake before the last character scan the CANCEL barcode to abort and not save the entry string You can then start again at the begin ning 6 Scan the ENTER EXIT PROGRAMMING MO...

Page 240: ... in Appendix D Keypad that represent the number which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character scan the CANCEL barcode to abort and not save the entry string You can then start again at the begin ning 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode This completes the proced...

Page 241: ...ode to enter Programming Mode 4 Scan the barcode SELECT DISABLE CHARACTER SETTING 5 Scan the appropriate two alpha numeric characters from the keypad in Appendix D Key pad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode This completes the procedure See Table 29 f...

Page 242: ...ired character value 3 Go to page 32 and scan the ENTER EXIT PROGRAMMING MODE barcode to enter Programming Mode 4 Scan the barcode SELECT ENABLE CHARACTER SETTING 5 Scan the appropriate two alpha numeric characters from the keypad in Appendix D Key pad that represent the desired character value in step 2 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING ...

Page 243: ...nned symbology AIM ID This function is used to identify and display the common label identifier for its symbology When enabled this ID code will be transmitted before the scanned bar code data OR Additional advanced editing is available See the Advanced formatting features in the Datalogic Aladdin configuration software or contact Technical Support described on page 8 for more information Please K...

Page 244: ...an the ENTER EXIT PROGRAMMING MODE barcode 3 Scan the SET GLOBAL PREFIX barcode 4 Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired character The corresponding hex number for the character is 24 To enter this selection code scan the 2 and 4 barcodes from Appendix D Keypad If you make a mistake before the last character scan the CANCEL b...

Page 245: ... A close brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN Ea a UPC A and UPC E labels are converted to EAN 13 when adding AIM IDs Code 128 GS1 128 C Code 39 and Code 32 A DataBar Omnidirectional DataBar Expanded e Codabar F Standard 2 of 5 S Interleaved 2 of 5 I I...

Page 246: ... The reader supports two pre loaded sets of Label IDs Table 31 shows the USA and the EU sets CAUTION When changing from one Label ID set to another all other reader configu ration settings including the host interface type will be erased and set to the standard factory defaults Any custom configuration or custom defaults will be lost Table 31 Label ID Pre loaded Sets Symbology USA Label ID set EU ...

Page 247: ...00 GTIN G 470000 A 244100 GTIN2 G2 473200 B 244200 GTIN5 G5 473500 C 244300 IATA IA 494100 260000 Industrial 2 of 5 W 570000 W 570000 Interleaved 2 of 5 i 690000 N 4E0000 ISBN I 490000 400000 ISBT128 f 660000 f 660000 ISSN n 6E0000 n 6E0000 MSI 400000 Z 5A0000 Plessey a 610000 a 610000 S25 s 730000 P 500000 UPCA A 410000 C 430000 UPCA P2 A 410000 F 460000 UPCA P5 A 410000 G 470000 Data Editing Pro...

Page 248: ...bology 5 Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a Label ID the chart indicates its associated hex characters as 3D Turn to Keypad starting on page 277 and scan the barcodes representing the hex characters deter mined For the example given the charac...

Page 249: ...e 46 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII Chart inside back cover then scan in these digits characters using the barcodes in the section Keypad starting on page 277 If you make a mistake before the last character scan the CANCEL barcode to abort and not save the entry string You can...

Page 250: ... FF To set Character Conversion 1 Go to page 55 and scan the ENTER EXIT barcode 2 Scan the Configure Character Conversion barcode 3 Determine the desired string Sixteen positions must be determined as in the above exam ple Next turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string 4 Turn to Appendix D Keypad and scan the bar...

Page 251: ...e code verifier Match String then it is sent to the host through the configured port If it does not match the code verifier Match String either the Wrong Code can be sent or the defined Wrong String message can be sent indicating the error Match String The string used as the match code for code verification The Match String must be configured to include start stop characters and check digits if th...

Page 252: ...nd scan ENTER EXIT PROGRAMMING MODE to enter Programming Mode 4 Scan the barcode SELECT WRONG CODE STRING 5 Turn to Appendix D Keypad and scan the barcodes representing the hex characters deter mined in step 1 above 6 If less than the expected string of 20 characters are selected scan the ENTER EXIT bar code to terminate the string 7 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming...

Page 253: ...conds milliseconds in 100ms increments Follow these instructions to set this feature 1 Determine the desired setting in milliseconds A setting of 0 means that the good read LED stays on until the next time the trigger is pulled 2 Divide the desired setting by 100 setting is in 100ms increments Pad the result with leading zeroes to yield three digits For example 0 000 5 005 20 020 etc 3 Go to page ...

Page 254: ...he Phase events can be signals coming from the trigger button or external presence sensor connected to the scanner input for RS232 models On Line mode allows the following configurations Phase Off Event Specifies whether the reading phase is closed on a timeout or phase off event The following selections are available Trigger Stop the reading phase ends when the trigger event stops Timeout is disa...

Page 255: ...llowed until the label has left the reading area In order to guarantee identification of the code in the reading zone a threshold specifies the number of scans after the successful decode that the scanner will wait before rearming the reading phase The transmission of the decoded label depends on the configuration of the Transmission Mode parameter Automatic mode configurations Automatic Threshold...

Page 256: ...n details Scan rate is fixed to 3 25 msec An automatic algorithm will be implemented in order to fulfil the dynamic reading performances required Special Recipes Special Recipes allow the user to select the best combination for reading parameters according to the specific application i e Code Color Code Contrast Code Resolution Power Save USB Suspend Enables or disables USB Suspend Mode This featu...

Page 257: ...onservative decoder at the expense of not being able to read poorly printed or damaged labels Level 5 results in a very aggressive decoder This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that det...

Page 258: ...beginning 5 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Prog Mode Set Length 2 This feature allows you to set one of the barcode lengths for the specified symbology Length 2 is the maximum label length if in Variable Length Mode or the second fixed length if in Fixed Length Mode See the page for the specific symbology for parameters The length that can be set varies depending on the symbo...

Page 259: ...ctrical Characteristics Input Voltage 5 VDC 5 External Trigger Input Only GFS4150 9 Voltage Current Consumption Minimum Pulse Duration 5 30 VDC Only GFS4150 9 10 mA max 5 ms Output Only GFS4150 9 Vce Collector Current Vce Saturation Power Dissipation 30 Vdc max 40 mA continuous max 1V max at 10 mA 80 mW max at 50 C ambient temperature Current Power Consumption Input current at 5V 390 mA max 2 5 mA...

Page 260: ...I 2 of 5 Standard 2 of 5 China Post Code DLS 2 of 5 IATA Industrial 2 of 5 Air Cargo Code Codabar ABC Codabar GS1 128 Code ISBT 128 MSI Plessey DATABAR 14 DATABAR Limited DATABAR 14 Stacked DATABAR Expanded Stacked Code32 Italian Pharmacode China Post DLS 2 of 5 Interfaces Supported GFS4150 9 model RS 232 Standard GFS4170 model USB COM Standard USB Keyboard User Environment Operative Temperature 3...

Page 261: ...connected 5 GND Ground 6 VCC 5Vdc 7 CTS Clear To Send 8 RTS Request To Send 9 OUT Output signal see Figure 35 below Default configuration RS 232 9600 8 N 1 no handshaking ACK NAK disabled Figure 35 Output Connection OUT 9 30Vdc max GND 5 Vext USER INTERFACE GFS4150 9 Figure 36 Using GFS4150 9 Power EXT TRIGGER TRIGGER 1 GFS4150 9 GND 6 5 VCC Figure 37 Using External Power Supply EXT TRIGGER TRIGGE...

Page 262: ...Table 38 LED and Beeper Indications INDICATION DESCRIPTION LED BEEPER Power up Beep The reader is in the process of pow ering up Reader beeps four times at highest frequency and volume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indica tion is configurable via the feature Good Read When to Indicate The reader will beep once at cur rent fre...

Page 263: ...ted Programming Mode N A Reader sounds one high frequency beep and 4 low frequency beeps followed by reset beeps Label Program ming Mode Can cel Item Entry Cancel label has been scanned N A Reader sounds two times at low frequency and current volume Programming Mode Indications Error Codes Upon startup if the reader sounds a long tone this means the reader has not passed its automatic Selftest and...

Page 264: ...Technical Specifications 262 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 265: ...same configurable features Table 40 Standard Defaults Parameter Default Your Setting Page Number GLOBAL INTERFACE FEATURES Host Commands Obey Ignore Obey 19 RS 232 ONLY Baud Rate 9600 22 Data Bits 8 Data Bits 23 Stop Bits 1 Stop Bit 23 Parity None 24 Handshaking Control Disable 25 RS 232 USB COM Intercharacter Delay No Delay 27 Beep On ASCII BEL Disable 27 Beep On Not on File Enable 28 ACK Charact...

Page 266: ...abel ID Pre loaded Sets USA Set 44 Label ID Control Disable 45 Label ID Symbology Selection 46 Set Global Mid Label ID Characters No Mid Label ID Character 50 No Read String 0x18 CAN 51 Code Verifier Mode Disabled 52 Match String 53 Wrong Code String 54 Case Conversion Disable 54 Character Conversion No Char Conversion 55 DIGITAL OUTPUT Activation Event Disable 58 Deactivation Event Disable 59 Dea...

Page 267: ...ial Start Character 0x02 Serial Start Character is 02 STX 73 Serial Stop Character 0x03 Serial Stop Character is 03 ETX 73 Automatic Threshold 0x0A 10 74 Test Mode Multiple Disable 74 Exposure Mode Continuous 75 CODE SELECTION Coupon Control Enable UPCA coupon decoding 79 UPC A UPC A Enable Disable Enable 80 UPC A Check Character Transmission Enable 80 Expand UPC A to EAN 13 Disable 81 UPC A Numbe...

Page 268: ...le Disable Disable 90 EAN 8 EAN 8 Enable Disable Enable 91 EAN 8 Check Character Transmission Send 91 Expand EAN 8 to EAN 13 Disable 92 EAN 8 Minimum Reads 1 92 UPC EAN Global Settings UPC EAN Decoding Level 3 93 UPC EAN Correlation Disable 94 UPC EAN Price Weight Check Disable 94 In Store Minimum Reads 2 95 Add Ons Optional Add ons Disable P2 P5 and P8 96 Optional Add On Timer 70 ms 97 Optional G...

Page 269: ...ble Disable Disable 118 Code 32 Feature Setting Exceptions N A 118 Code 32 Check Char Transmission Don t Send 119 Code 32 Start Stop Character Transmission Don t Transmit 119 Code 39 CIP French Pharmaceutical Code Code 39 CIP Enable Disable Disable 118 Code 128 Code 128 Enable Disable Enable 121 Expand Code 128 to Code 39 Disable 121 Code 128 Check Character Transmission Send 122 Code 128 Function...

Page 270: ... 135 I 2 of 5 Minimum Reads 2 156 2 of 5 Decoding Level 3 156 I 2 of 5 Length Control Variable 138 I 2 of 5 Set Length 1 6 139 I 2 of 5 Set Length 2 50 140 I 2 of 5 Character Correlation Disable 141 I 2 of 5 Stitching Disable 141 Standard 2 of 5 Standard 2 of 5 Enable Disable Disable 142 Standard 2 of 5 Check Character Calculation Disable 142 Standard 2 of 5 Check Character Transmission Send 143 S...

Page 271: ...of 5 Datalogic 2 of 5 Enable Disable Disable 155 Datalogic 2 of 5 Check Character Calculation Disable 155 Datalogic 2 of 5 Minimum Reads 2 156 Datalogic 2 of 5 Decoding Level 3 156 Datalogic 2 of 5 Length Control Variable 157 Datalogic 2 of 5 Set Length 1 6 characters 158 Datalogic 2 of 5 Set Length 2 50 159 Datalogic 2 of 5 Character Correlation Disable 160 Datalogic 2 of 5 Stitching Disable 160 ...

Page 272: ...Bar Omnidirectional GS1 128 Emulation Disable 175 GS1 DataBar Omnidirectional Minimum Reads 1 176 GS1 DataBar Expanded GS1 DataBar Expanded Enable Disable Disable 177 GS1 DataBar Expanded GS1 128 Emulation Disable 177 GS1 DataBar Expanded Minimum Reads 1 178 GS1 DataBar Expanded Length Control Variable 178 GS1 DataBar Expanded Set Length 1 1 179 GS1 DataBar Expanded Set Length 2 74 180 GS1 DataBar...

Page 273: ... Length Control Variable 193 MSI Set Length 1 1 193 MSI Set Length 2 50 194 MSI Minimum Reads 4 195 MSI Decoding Level 3 196 MSI Stitching Disable 197 MSI Character Correlation Disable 197 Plessey Plessey Enable Disable Disable 198 Plessey Check Character Calculation Enable Plessey std check char verification 199 Plessey Check Character Transmission Enable 199 Plessey Length Control Variable 200 P...

Page 274: ...Standard Defaults 272 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 275: ...arcodes in this appendix are typical representations for their symbology types 0 12345 67890 5 UPC A 3 456789 012340 EAN 13 123ABC Code 39 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 Code 128 12345678901231 Interleaved 2 of 5 ...

Page 276: ...Sample Barcodes 274 Gryphon I GFS4170 GFS4150 9 Sample Barcodes continued A020096020 Code 32 Codabar Code 93 Code 11 ...

Page 277: ...jio9900mnb GS1 DataBar Expanded 08672345650916 GS1 DataBar Limited GS1 DataBar variants must be enabled to read the barcodes below see GS1 DataBar Omnidirectional on page 175 GS1 DataBar 14 55432198673467 GS1 DataBar Omnidirectional Truncated 90876523412674 GS1 DataBar Omnidirectional Stacked 78123465709811 GS1 DataBar Omnidirectional Stacked ...

Page 278: ...Sample Barcodes 276 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 279: ...Product Reference Guide 277 Appendix D Keypad Use the barcodes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5 ...

Page 280: ...Keypad 278 Gryphon I GFS4170 GFS4150 9 6 7 8 9 ...

Page 281: ...Keypad Product Reference Guide 279 A B C D E F ...

Page 282: ...Keypad 280 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 283: ...e Notes SOH 0x01 BEL 0x07 0x23 0x24 0 0x30 3 0x33 B 0X42 D 0X44 E 0X45 F 0X46 R 0X52 S 0X53 h 0x68 i 0x69 s 0x73 t 0x74 FF 0xFF Reserved Strings C up to 36 chars CR 0x43 xxx 0x0D C can be used without CR or inside a string not the first character 01 CR 0x30 0x31 0x0D 34 CR 0x33 0x34 0x0D ...

Page 284: ...282 Gryphon I GFS4170 GFS4150 9 NOTES ...

Page 285: ...ter Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table Microsoft Windows Codepage 1252 See page 288 Single Press and Release Keys In the following tables Ar means Alt right pressed and Ar means Alt right released and so on Definitions for other keys are Al...

Page 286: ... W CAN C S X EM C S Y SUB C S Z ESC Esc FS C GS C RS C US C S _ 2x SP 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12 Home End Pg Up Pg Dwn Ar Ar Al Al Cl Cl Cr Ax Cr ƒ ˆ Š Ś Œ Bx µ º Cx À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Dx Ð Ò Ó Ô Õ Ö Ø Ù Ú...

Page 287: ... Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x ƒ ˆ Š Ś Œ 9x š œ ž Ÿ Ax NBSP ª Bx µ º Cx À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Dx Ð Ò Ó Ô Õ Ö Ø Ù Ú Û Ü Ý Þ ß Ex à á â ã ä å æ ç è é ê ë ì í î ï Fx ð ñ ò ó ô õ ...

Page 288: ...2 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12 Home End Pg Up Pg Dwn Ar Ar Al Al Cl Cl Cr Ax Cr A 0161 A 0162 A 0163 A 0164 A 0165 A 0166 A 0167 A 0168 A 0169 A 0170...

Page 289: ...114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 0142 A 0143 9x A 0144 A 0145 A 0146 A 0147 A 0148 A 0149 A 0150 A 0151 A 0152 A 0153 A 0154 A 0155 A 0156 A 0157 A 0158 A 0159 Ax A 0160 A 0161 A 0162 A 0163 A 0164 A 0165 A 0166 A 0167 A 0168 A 0169 A 0170 A 0171 A...

Page 290: ... GFS4170 GFS4150 9 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy components of Microsoft Windows in English and some other Western languages ...

Page 291: ...talogic Aladdin 9 Defaults 263 E Error Codes 261 Errors 261 G Good Read Beeper 66 Pitch 67 Good Read Beeper 66 Good Read Beeper Pitch 67 Green Spot 260 I Indications 260 Interface Cable 12 ISSN 90 K keyboard support 34 P Pitch Good Read Beeper 67 Prefix Suffix 42 242 Product Specifications 257 Programming Barcodes 9 R Read Beeper Good 66 Read Beeper Pitch Good 67 Reading Configuration Barcodes 18 ...

Page 292: ...Gryphon I GFS4170 GFS4150 9 Index code 128 273 code 39 273 interleaved 2 of 5 274 Scancode Tables 283 select digits characters 277 Suffix 42 242 symbology types 273 U UPC 80 USB Connection 12 X XON XOFF 234 ...

Page 293: ...3 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F a b c d e f g h i j k l m n o p q r s t u v w x y z DEL 60 61 62 63 64 65 66 67 68 69 6A 6B 6...

Page 294: ...64504739 india scanning datalogic com Italy Datalogic Scanning SpA Telephone 39 0 39 62903 1 italy scanning datalogic com Japan Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 742 2206 latinamerica scanning datalogic com Singapore Datalogic Scanning Singapore PTE LTD Telephone 65 6435 1311 singapore scanning datalogic...

Reviews: