![Datalogic Gryphon GFS4100 Product Reference Manual Download Page 240](http://html1.mh-extra.com/html/datalogic/gryphon-gfs4100/gryphon-gfs4100_product-reference-manual_511984240.webp)
References
238
Gryphon™ I GFS4170/GFS4150-9
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry
condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and
a selection of 255 specifies unlimited retries.
To set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005,
20 = 020, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING.
5. Scan the appropriate three digits from the keypad in
, that represent
the number which was determined in the steps above. You will hear a two-beep indication
after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table
28
for some examples of how to set this feature.
Table 28. ACK NAK Retry Count Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Disable Retry
Count
3 Retries
54 Retries
Unlimited Retries
2
Pad with leading zero(es)
000
003
054
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK NAK RETRY COUNT SETTING
5
Scan Three Characters From
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘3’
‘0’, ‘5’ and ‘4’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Gryphon GFS4100
Page 1: ...Gryphon I GFS4100 Fixed Mount Linear Imager Bar Code Reader Product Reference Guide ...
Page 12: ...Introduction 10 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 22: ...Configuration Using Barcodes ENTER EXIT PROGRAMMING MODE 20 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 42: ...USB Keyboard Interfaces ENTER EXIT PROGRAMMING MODE 40 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 58: ...Data Format ENTER EXIT PROGRAMMING MODE 56 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 66: ...Power Save ENTER EXIT PROGRAMMING MODE 64 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 78: ...Reading Parameters 76 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 208: ...Plessey ENTER EXIT PROGRAMMING MODE 206 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 234: ...Software Configuration Strings 232 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 264: ...Technical Specifications 262 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 274: ...Standard Defaults 272 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 278: ...Sample Barcodes 276 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 280: ...Keypad 278 Gryphon I GFS4170 GFS4150 9 6 7 8 9 ...
Page 281: ...Keypad Product Reference Guide 279 A B C D E F ...
Page 282: ...Keypad 280 Gryphon I GFS4170 GFS4150 9 NOTES ...