![Datalogic Gryphon GFS4100 Product Reference Manual Download Page 255](http://html1.mh-extra.com/html/datalogic/gryphon-gfs4100/gryphon-gfs4100_product-reference-manual_511984255.webp)
Test Mode
Product Reference Guide
253
Serial Start Character (or String):
Specifies the string message to be sent over the host interface
to activate the reading phase
Serial Stop Character (or String):
Specifies the string message to be sent over the host interface
to stop the reading phase.
The Serial Start/Stop Characters must be different and must not contain
reserved characters (see
Appendix E, Reserved Characters
Phase Off Event:
Specifies whether the reading phase is closed on a timeout or phase off event.
The following selections are available:
•
Trigger Stop: the reading phase ends when the serial stop character (or string) is received.
Timeout is disabled.
•
Timeout: the reading phase ends when the timeout is expired. Serial stop character (or
string) is ignored.
•
Trigger Stop - Timeout: the reading phase ends when the first event occured.
Timeout:
Specifies the maximum duration for the reading phase. Selections: from 40 to 5100
ms in 20 ms increments.
Automatic
In Automatic mode, the scanner is continuously scanning. When a label enters the reading zone
and is decoded, no more decodes and reading phases are allowed until the label has left the
reading area. In order to guarantee identification of the code in the reading zone, a threshold
specifies the number of scans after the successful decode that the scanner will wait before
rearming the reading phase. The transmission of the decoded label depends on the
configuration of the Transmission Mode parameter.
Automatic mode configurations:
Automatic Threshold:
Specifies the number of “empty” scans allowed after decoding a label,
before the scanner switches back to a new reading phase.
Automatic/Trigger Object Sense
Automatic/TOS mode is the same as Automatic mode, but with the lighting system OFF. As an
object or barcode enters the reading area, the light is turned ON. The light will return OFF as
the reading phase is closed (see Automatic Mode above).
While in Trigger Object Sense Mode the green spot stays on while in
stand watch state.
Test Mode
Test Mode reports information about the reading performance of the reader, and the code is
continuosly read. After 100 scans, the following information is transmitted to the Host:
•
The code content
•
Percentage of good reads. If the good read percentage is 0, no transmission occurs.
The information can be displayed on the Host PC by running a terminal emulator program
such as HyperTerminal. The output data format is fixed.
Summary of Contents for Gryphon GFS4100
Page 1: ...Gryphon I GFS4100 Fixed Mount Linear Imager Bar Code Reader Product Reference Guide ...
Page 12: ...Introduction 10 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 22: ...Configuration Using Barcodes ENTER EXIT PROGRAMMING MODE 20 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 42: ...USB Keyboard Interfaces ENTER EXIT PROGRAMMING MODE 40 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 58: ...Data Format ENTER EXIT PROGRAMMING MODE 56 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 66: ...Power Save ENTER EXIT PROGRAMMING MODE 64 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 78: ...Reading Parameters 76 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 208: ...Plessey ENTER EXIT PROGRAMMING MODE 206 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 234: ...Software Configuration Strings 232 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 264: ...Technical Specifications 262 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 274: ...Standard Defaults 272 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 278: ...Sample Barcodes 276 Gryphon I GFS4170 GFS4150 9 NOTES ...
Page 280: ...Keypad 278 Gryphon I GFS4170 GFS4150 9 6 7 8 9 ...
Page 281: ...Keypad Product Reference Guide 279 A B C D E F ...
Page 282: ...Keypad 280 Gryphon I GFS4170 GFS4150 9 NOTES ...