3 - 24
Maximum Link Attempts
The Maximum Link Attempts setting controls the number of times the scan-
ner tries to form a connection with a base. During the connection setup
process, the scanner transmits in order to search for and connect to a
base. In order to prevent continuous transmissions that could interfere with
other users of the ISM band, the number of attempts to connect is limited
by this setting. After the maximum number of attempts is reached, the
scanner will not attempt to reconnect to a base. Pressing the scanner’s
button or placing the scanner in the base resets the attempt count and the
scanner will again try to link.
Scan the
Maximum Link Attempts
bar code, then scan the number of
attempts for the setting (from 0-255) from the inside back cover. Scan
Save to save the setting.
Default = 0.
Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts
to zero will cause the scanner to try to link until the Power Time-Out
Timer setting (see
) expires. When Auto Reconnect Mode
is Off, setting Maximum Link Attempts to zero will cause the scanner
to only attempt linking one time after a button press.
Relink Time-Out
Relink Time-Out controls the idle time between relink attempts. An attempt
to link a scanner to a base typically lasts up to 5 seconds. This is the time
when the scanner is actually attempting a contact . Relink Time-Out con-
trols the amount of time, in seconds, that elapses between the end of one
connection attempt and the start of the next.
Scan the
Relink Time-Out
bar code, then scan the number of seconds for
the setting (from 1-100) from the inside back cover. Scan
Save
to save the
setting.
Default = 3 seconds.
Bluetooth/ISM Network Activity Examples
Default values
When the scanner goes out of range, the scanner repeatedly attempts to
connect to the base unit. Each attempt consists of approximately 5 sec-
onds of active time followed by 3 seconds of idle time. After one hour, the
scanner powers off and batch mode data is lost.
Maximum Link Attempts
Relink Time-Out
Summary of Contents for VOYAGER 1200G
Page 1: ... Voyager 1200g 1202g Single Line Laser Bar Code Scanner User s Guide ...
Page 16: ......
Page 26: ...x ASCII Conversion Chart Code Page 1252 A 4 Code Page Mapping of Printed Barcodes A 6 ...
Page 36: ...1 10 ...
Page 80: ...3 16 Quantity Codes 1 0 3 2 4 6 5 7 8 9 ...
Page 90: ...3 26 ...
Page 122: ...5 10 ...
Page 134: ...6 12 ...
Page 202: ...7 68 ...
Page 206: ...8 4 ...
Page 210: ...9 4 ...
Page 260: ...11 6 CCB00 010BT Mounting 3 07 in 78mm Use 2 M3x15mm PHP self tapping wood screws ...
Page 274: ...13 4 ...
Page 282: ...A 8 ...
Page 283: ......
Page 285: ...Sample Symbols 6543210 GS1 DataBar 01 00123456789012 Matrix 2 of 5 ...
Page 286: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...
Page 288: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 VG1200 UG Rev B 11 11 ...