background image

3

Installation Instructions Viewguard DUAL / AM FAI

7.

Technical specification

Operating voltage Vnom

12 V DC

Operating voltge range

8.0 V to 15 V DC

Current consumption at Vnom=12 V DC

6.6 mA

Range (programmable):

8 / 11 / 13 / 15 m
PIR and MW together

PIR sensor

temperature-compensated

PIR sensitivity (programmable):

normal / high

(only 033440/450)

up to 30 cm

Frequency microwave:
-

033440 / 033441

9.35 GHz (X band)

-

033450 / 033451

10.587 GHz (X band)

Installation position

vertical, optics at bottom

Alarm contact:
-

Contact rating

15 V DC / 0.1 A

-

Internal resistance

25

-

Contact position

open in the event of alarm

Fault contact:
-

Contact rating

15 V DC / 0.1 A

-

Internal resistance

25

-

Contact position

open in the event of fault

Tamper contact:
-

Contact rating

15 V DC / 0.1 A

-

Internal resistance

10

-

Contact position

open in the event of tamper

Protection category as per EN 60529

IP 30

Environmental class as per VdS

II

Operating temperature range

-10 °C to +55 °C

Storage temperature range

-25 °C to +70 °C

Dimensions W x H x D

64 x 158 x 48 mm

Colour

White
(similar to RAL 9010)

Anti-Mask function

£ W

£ W

£ W

8.

Accessories

033390

Adjustable joint

033588

Ball-and-socket set for wall and corner mounting

033391

Seal

Swivel range:

Horizontal
Ve4° up to -8°

(PU = 20 piece)

±20°

033440 / 033450

Viewguard DUAL AM FAI DIN CLC/TS 50131-2-4 grade 3

033441 / 033451

Viewguard DUAL FAI

DIN CLC/TS 50131-2-4 grade 2

The detectors Viewguard DUAL AM FAI, Item no. 033440 / 033450 and Viewguard DUAL
FAI, Item no. 033441 / 033451 when used as intended, comply with the basic require-
ments of Article 3 of the R&TTE

The EU conformity declaration can be downloaded at
"www.honeywell.com/security/de" under Service-/ Download.

The devices may only be sold and operated in the following countries:

Germany, Austria, Switzerland, Liechtenstein, Poland, Slovakia, Czech Republic,
Luxembourg, Turkey, Greece, Latvia, Lithuania, Hungary, Belgium and Netherlands.

France, Spain, Italy, Portugal and United Kingdom.

9.

EU conformity

033440 / 033441:

033450 / 033451:

6.

LED indication

on

flashing

blanked

1)

No LED indication in Easy Logic mode

2)

See table in Chapter 4.1 "Function of inputs", function c).

Operating Mode

Red

Yellow

What

Indication reset

Start up

When power on

After 30 sec.

Walk test

Motion detected

Covering detected

Failed self test

After disarming

First alarm

Clear signal from control panel

with preceding

alarm

Subsequent alarm

Normal operation

Automatically without motion

When covering is removed

When fault is eliminated

Clear signal from control panel

1)

2)

2)

Subject to change without notice

LED yellow: see Fig. 2-

LED red: see Fig. 2-

���

���

Summary of Contents for Viewguard DUAL AM FAI

Page 1: ...E F NL Installation Instructions Instrucciones de instalación Notice d installation Installatievoorschriften GB E F Page 2 Página 4 Page 6 NL Kant 8 Fig 1 Fig 3 Fig 4 Fig 6 2 5m 5m 10m 15m 0m 0 10 20 30 40 10 20 30 40 0m 9m 9m 5m 10m 15m 0m 0 Fig 5 1 A C B D b A B D C a a DUAL AM FAI DUAL FAI Fig 5 0 45 45 5 1 5 2 5 3 5 4 a b c ...

Page 2: ...amper a b 4 2 Easy Logic operating mode without FAI function The control signals Walk test disarmed and FAI are not connected In this operating mode no alarm indication no FAI function and no memory is available The DIP switches S4 S5 and S6 must be in position ON The Microwave sensor is always active Detector 1 F Detector 2 Detector 3 Detector 20 F F F Function of inputs Pull up resistors in the ...

Page 3: ...g 033391 Seal Swivel range Horizontal Vertical 4 up to 8 PU 20 piece 20 033440 033450 Viewguard DUAL AM FAI DIN CLC TS 50131 2 4 grade 3 033441 033451 Viewguard DUAL FAI DIN CLC TS 50131 2 4 grade 2 The detectors Viewguard DUAL AM FAI Item no 033440 033450 and Viewguard DUAL FAI Item no 033441 033451 when used as intended comply with the basic require ments of Article 3 of the R TTE TheEUconformit...

Page 4: ...temas que funcionan de forma totalmente independiente Detector pasivo de infrarrojos más detector de microondas El principio de funcionamiento del detector se basa en la conexión inteligente de un sensor de infrarrojos pasivo y microondas Este tipo de conexión hace que los detectores sean especialmente insensibles a las turbulencias de aire y térmicas Módulo de microondas véase la ilust 3 Dispone ...

Page 5: ...ción anti enmascaramiento W W W 8 Accesorios 9 Conformidad CE 033390 033588 Juegoderótulasparamontajeenparedyesquina 033391 Sello Rótula de montaje Alcance de giro Horizontal 20 Vertical 4 hasta 8 PU 20 unidades LadeclaracióndeconformidadUEpuededescargarseen 033440 033450 Viewguard DUAL AM FAI CLC TS 50131 2 4 Grado 3 033441 033451 Viewguard DUAL FAI CLC TS 50131 2 4 Grado 2 Los detectores Viewgua...

Page 6: ...mment la détection infrarouge passif et la détection hyperfréquence Le principe de fonctionnement du détecteur repose sur la liaison intelligente entre la détection infrarouge passif et la détection hyperfréquence Ce type de liaison garantit l insensibilité des détecteurs aux mouvements d air et aux variations de température module à hyper fréquence voir Fig 3 Ces derniers présentent les caractéri...

Page 7: ...ype de relais NF Ouvert en cas de défaut Contact d autoprotection Pouvoir de coupure 15 Vcc 0 1 A Résistance interne 10 Type de contact NF Ouvert en cas d autoprotection Catégorie de protection selon EN 60529 IP 30 Température de fonctionnement 10 C à 55 C Température de stockage 25 C à 70 C Dimensions l x h x p 64 x 158 x 48 mm Couleur Blanc semblable à RAL 9010 Fonction anti masque W W W 8 Acces...

Page 8: ... systemen die volledig onafhankelijk van elkaar functioneren Een passief infraroodmelder en een microgolfmelder De werking van de melder is gebaseerd op de intelligente koppeling van een passief infraroodsensor en microgolven Door deze combinatie zijn de melders bijzonder ongevoelig voorluchtturbulentieofthermischeturbulentie microgolfmodule zieafb 3 Deze beschikken over de volgende hoofdeigenscha...

Page 9: ...geuitgang Max contactbelasting 15 V DC 0 1 A Interne weerstand 10 Status open in geval van een sabotage Beschermklasse conform EN 60529 IP 30 Milieuklasse conform VdS II Bedrijfstemperatuur 10 C tot 55 C Opslagtemperatuur 25 C tot 70 C Afmetingen B x H x D 64 x 158 x 48 mm Kleur wit vergelijkbaar met RAL 9010 Anti masking functie W W W 8 Accessoires 9 EU conformiteit 033390 Verstelbare 033588 voor...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...P01715 10 007 00 24 10 2007 2007 Novar GmbH ...

Reviews: