DEVICE DESCRIPTION
2
15
VERSAFLOW VORTEX 200
www.honeywellprocess.com
34-VF-25-137 iss.1 GLO July 2019 US
Max. permissible product and ambient temperatures with signal converter in stainless
steel (bright) or connection box in stainless steel (bright) mounted above the flow
sensor
Temperature class
T6
T5
T4
T3
T2
T
amb
in
°
C
60
65
60
65
60
65
40
60
65
40
60
65
Nominal size
DN15
…
25
75
65
100
100
135 135
1
200 170
1
145
1
225
170
1
145
1
DN40
…
50
75
65
100 100
1
135
1
130
1
200 150
1
130
1
235
150
1
130
1
DN65
…
100
75
65
100 100
1
135
1
115
1
195
1
135
1
115
1
195
1
135
1
115
1
DN150...300
75
65
100 100
1
135
1
135
1
200 155
1
135
1
230
155
1
135
1
Table 2-15: Temperature class in
°
C
1
Permanent service temperature of connecting cable and cable entry min. 80
°
C
Temperature class
T6
T5
T4
T3
T2
T
amb
in
°
F
140 149 140
149
140
149
104
140
149
104
140
149
Nominal size
DN15
…
25
167
149
212
212
275 275
1
392 338
1
293
1
437
338
1
293
1
DN40
…
50
167
149
212 212
1
275
1
266
1
392 302
1
266
1
455
302
1
266
1
DN65
…
100
167
149
212 212
1
274
1
239
1
383
1
274
1
239
1
383
1
274
1
239
1
DN150...300
167
149
212 212
1
275
1
275
1
392 311
1
275
1
446
311
1
275
1
Table 2-16: Temperature class in
°
F
1
Permanent service temperature of connecting cable and cable entry min. 176
°
F