Installation Manual

Summary of Contents for temaline RTU A01P

Page 1: ...Page 1 TK C21P RTU A01P TK C21S RTU A11 Installation Manual ...

Page 2: ... agreement with and for its customer In no event is Honeywell liable to anyone for any direct special or consequential damages The information and specifications in this document are subject to change without notice Trademarks Tema VoyagerTM is a trademark of Honeywell International Inc MIFARE is a registered trademark of Philips Electronics N V HID is a trademark or registered trademark of HID Gl...

Page 3: ...amper Option 13 Elemental Detail 15 Jumpers 16 Harsh environment 17 Closing the Unit 18 TECHNICAL SPECIFICATIONS 19 TemaKey TK C21P RTU A01P code 1500163xx 19 REGULATIONS COMPLIANCE 21 CE Compliance 21 Canadian and United States UL Listed 21 FCC Compliance 21 RoHS compliance 22 WEEE compliance 22 China RoHS declaration 22 ACTIVATION 23 Identification via the Service Pin 23 Identification via Bar C...

Page 4: ...Page left intentionally blank ...

Page 5: ... on which the RTU A01P unit will be mounted Figure 1 indicates the minimum size of the panel If you need to install additional RTU A01P modules you can use a larger panel however make sure that you allow sufficient space for accessing the cables 120mm min 150mm min 80mm min interior depth DIN RAIL CABLE ENTRY POINT 45mm min Figure 1 Box with DIN Ω Rail ...

Page 6: ... 37 15 12 3 3 5 7 439 219 88 44 22 9 14 2 8 8 284 142 57 28 14 6 16 1 3 14 179 89 36 18 9 4 18 0 9 21 119 60 24 12 6 2 20 0 6 34 74 37 15 7 4 1 22 0 35 52 48 24 10 5 2 1 The LONWORKS 1 data cable must be twisted pair In a free topology configuration the sum total of the sections must not exceed 500m In a bus configuration the sum total of the sections must not exceed 2700m In a free topology confi...

Page 7: ... 155 Table 1 Length Capacity of LONWORKS Data Cables The FTT10A Echelon v1 2 User Guide recommends the cables indicated in Table 2 Producer and Model AWG Connection to bus maximum total length m Connection in free topology maximum node node length max m Connection in free topology maximum total wire length m Belden 85102 16 2700 500 500 Belden 8471 16 2700 400 500 Level IV twisted pair typically s...

Page 8: ...g Up the Unit To hook up the unit follow these steps 1 Rest the upper panel of the RTU A01P on the rail 2 Press until you hear the tongue click into position on the rail see Figure 2 TONGUE ROTATE Figure 2 Hooking Up the Unit to the DIN Rail ...

Page 9: ...Place the resistors next to the contacts themselves as illustrated in Figure 3 contact 3 In V contact 4 white In V contact 2 In V contact 1 In V V V V V out out out out white white white yellow yellow yellow yellow JP3 JP2 SW1 J4 J5 J4 J3 J1 J2 LED1 SW1 J3 J2 J1 Figure 3 Connecting the Supervised Contact Cables Yellow resistor 1210 Ohm 1 White resistor 392 Ohm 1 Close contact resistance 296 Ohm Op...

Page 10: ...e well separated even at short runs especially to the power cables or external cables which can be essentially subjected to interference or lighting Use a twisted pair cable for the contact cables Make sure that the cables correspond in size to the norms indicated in Max contact resistance 25 Ohm Cable type Lenght AWG mm2 ohm Km m 12 3 3 5 7 2193 14 2 8 8 1420 16 1 3 14 893 18 0 9 21 595 20 0 6 34...

Page 11: ... tamper contact SENSOR black yellow white power supply xsclusion idem idem idem In Out JP3 JP2 J5 J4 J3 J1 J2 J3 J4 Figure 4 Connecting the Sensor Cables Yellow resistor 1210 Ohm 1 White resistor 392 Ohm 1 Black resistor 3920 Ohm 1 Close contact resistance 296 Ohm Open contact resistance 1210 Ohm Tamper contact resistance 3920 296 Ohm or 3920 1210 Ohm ...

Page 12: ...or 5 wire if the sensor is provided with input disable cables for the connections to the sensors Make sure that the cables correspond in size to the norms indicated in Table 4 maximum voltage drop on the cable 0 1V Cable length m 0 1V I A load x 2 x res Ohm km 1000 I load max for each sensor 100mA 400mA overall Length m Type of cable in relation to currentabsorbed by sensor AWG mm2 ohm Km 20 mA 50...

Page 13: ...ed cables The cables shielding must be connected to the respective ground connectors V For internal wiring without shielded cables is recommended an electrical environment where the cables are well separated even at short runs especially to the power cables or external cables which can be essentially subjected to interference or lighting In V V out In V V out In V V out In V V out JP3 JP2 SW1 J4 J...

Page 14: ...r supply GND GND GND GND 10 30VDC LOAD 1 LOAD 2 LOAD 3 LOAD 4 1N4004 1N4004 1N4004 1N4004 Figure 6 Connecting to inductive loads with an external isolated power supply Note for inductive loads In this case is mandatory use the 1N4004 diodes as in figure Four 4 Diodes are included in the product The external power supply have to be isolated ...

Page 15: ...ut Relay 2 In V V out Relay 1 In V V out JP3 JP2 SW1 J4 J5 J4 J3 J5 J2 LED1 SW1 J3 J2 J1 1N4004 1N4004 1N4004 1N4004 Figure 7 Connecting the Relays Notes Use 12VDC relay max coil current 100mA each In this case is mandatory use the 1N4004 diodes as in figure ...

Page 16: ...TION LON and Power connection Connect the LONWORKS data cable and the two power cables to connector J5 as illustrated in Figure 8 LON 12 LONWORKS POWER SUPPLY 12VDC SW1 J5 J2 LED1 SW1 Figure 8 LON and power Connection ...

Page 17: ...is no need to place the safety cover on the RTU A01P unit The anti opening tamper on the box protects all the contents the unit itself the cables and the anti removal tamper If the box contains several RTU A01P units it is only necessary to mount the anti removal option on one of them 3 Connect the anti removal and the anti opening tampers to their respective jumpers JP2 and JP3 on the RTU A01P un...

Page 18: ...Page 14 INSTALLATION Figure 9 Anti Removal Tamper Option ...

Page 19: ...ic card including the main connectors and jumpers JP3 JP2 SW1 J4 J5 J4 J3 J5 LED1 SW1 service button service LED tamper switch I O1 I O2 I O3 I O4 LON In Out In Out In Out In Out 1 2 3 4 26 27 28 29 30 31 32 33 18 19 20 21 22 23 24 25 J3 J2 J1 Tamper Jumpers JP2 NO JP3 NC Figure 10 Elemental Detail ...

Page 20: ...r open JP3 anti removal tamper inserted Table 5 Configuration of Jumpers If the anti opening and anti removal tampers are present on the board connect the corresponding cables to JP2 and JP3 respectively In this situation the internal tamper does not serve any purpose and there is no need to replace the upper safety cover of the unit which can therefore be left open ...

Page 21: ...able shielded with the shield connected to Earth in an only point and separate to the internal Ground Inputs cable shielded as in the Figure 3 Output use direct outs only if the load is at a distance less than 3 mt with an unshielded cable well separate to others cables If the load distance is more than 3 mt use the external relays to mount close to the RTUA01P at a distance less than 3 mt connect...

Page 22: ...e the unit follow these steps see Figure 11 1 Place the safety cover onto the lower part of the unit 2 Screw down the safety cover using the 4 self tapping screws you will need a 3mm Philips screwdriver Honeywell RTUA01P Figure 11 Closing the Unit ...

Page 23: ... LONWORKS Connection Unshielded twisted pair cable in free topology Echelon FT3120E4 RoHS chip Outputs Number 4 Type Power Open drain MOSFET Current 1 2A continuous 5A 0 5sec impulsive Voltage 10V 14V internal Power supply Voltage absolute max 10V 30V from external Power supply Current 1 2A 5A 0 5sec peak max inductive load Normality NO or NC via software setting Wire length connection it depends ...

Page 24: ...CAL SPECIFICATIONS Type Supervised Current 0 3mA for each input internal reference Voltage 14V max 0V min Min detection time 250 msec Power Output for external devices 12V 15 300mA Max overall internal PTC protection ...

Page 25: ...and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communica...

Page 26: ...EEE effective beginning 14 February 2014 Honeywell commits when requested by the customer to the collection treatment recovery and disposal of apparatus produced Customers in European Union are advised to dispose this product at the end of its useful life as per applicable local laws regulations and procedures China RoHS declaration This product contains toxic and hazardous substances or elements ...

Page 27: ...1 Place a magnet in front of the service reed sensor see Figure 14 2 The TemaServer then sends a wink command in response to the service pin which makes yellow LED flash for 2 seconds This allows you to verify that communication to and from the TemaServer is working 3 Check that the service LED remains off after you have completed this operation SERVICE LED SERVICE REED SENSOR MAGNET Honeywell RTU...

Page 28: ...e appropriate box see example in Table 6 Description of location Office entrance area first floor staircase E Description of TemaServer Panel 2 entrance area first floor staircase E RTU A01P Input 1 Contact at entrance to offices Output 1 X Input 2 Contact at staircase entrance Output 2 X Input 3 Microwave sensor entrance to offices Output 3 Input 4 Infra red sensor entrance to offices Output 4 Ta...

Page 29: ...ACTIVATION Page 25 Identification Form Description of location Description of TemaServer RTU A01P Input 1 Output 1 Input 2 Output 2 Input 3 Output 3 Input 4 Output 4 Notes Bar code label with Neuron ID ...

Page 30: ...Page 26 ACTIVATION Spare Parts Yellow resistor Code 1651067 Black resistor Code 1651068 White resistor Code 1651069 Resistor kit Code 1584927 ...

Page 31: ...l be kept away from rain and in dry conditions Carton Box Fragile handle with care To indicate that the contents of the transport package are fragile and the package shall be handled with care Carton Box This way up To indicate correct upright position of the transport package Carton Box Conformité Européenne To indicate the manufacturer declares that the product meets the requirements of the appl...

Page 32: ...OLS USED Recycling To indicate compliance with EC directive regarding waste electrical and electronic apparatus Label China RoHS environmental protection use period Indicates the environmental protection use period of the product Label ...