background image

29 

29 

tower icon will start flashing next to the clock icon. If reception is 
disabled, the triangular tower icon will disappear. 

Icon 

Atomic Time Reception Strength 

    (Flashing) 

Undefined data 

 

Reception failed for the past 24 hours 

 

Weak signal, but can be decoded 

 

Strong signal 

 

 
SUNRISE/SUNSET WINDOW 

The main unit is able to calculate the sunrise and sunset times depending on 
the user defined location. The location data contains the longitude, latitude, 
time zone and DST (Daylight Saving Time). 
If the closest city code is selected, the main unit will automatically generate all 
of the correct data for specified location. 
If you cannot find the closest city code or would like to enter your specific 
location, select 

“USR

” as the city code during the setup.   

A search function is also available. It allows viewing the sunrise/sunset times 
for different dates. 

 
ACCESSING SUNRISE/SUNSET WINDOW 

Press 

UP

 or 

DOWN

 until the sunrise and sunset icons 

 

 on the lower 

left of the display will start flashing. 

 
 

30 

PROGRAMMING YOUR LOCATION 

 

In Sunrise/Sunset Window, press and hold 

SET

 until the city code in 

the Clock Window will flash entering the location programming mode. 

 

Select the city code closest to your area by pressing the 

UP

 or 

DOWN.

 

Refer to P. for a list of available codes. The corresponding longitude 
and latitude will be displayed in Sunrise/Sunset Window along with the 
city code. 

 

If you wish to enter the geographical coordinates yourself, select the 

“USR”

 (user) as a city code. 

 

Press 

SET

 to confirm your selection and enter into the geographical 

coordinates programming mode – the latitude degrees will flash 

 
PROGRAMMING LATITUDE, LONGITUDE, TIME ZONE AND DST
 

 

Press 

UP

 or 

DOWN

 to adjust the digits. Press and hold either button 

for fast advance. 

 

Press 

SET

 to confirm your selection. 

 

Repeat above procedure to set latitude and longitude minutes, 
longitude degrees, time zone, and DST selection. 

 

Once programming is completed, the display will return to the 
Sunrise/Sunset Window. 

 
VIEWING LOCATION DATA 

In 

Sunrise/Sunset Window

 press 

SET

 selecting either: 

 

Time and sunrise/sunset times 

 

Calendar and sunrise/sunset times   

 

Calendar and longitude/latitude   

 
 

Summary of Contents for TD43996615 - HON-TE852W

Page 1: ...D METER 8 MAIN UNIT 10 NAVIGATING THROUGH THE MODES 16 CUSTOMAZING YOUR WEATHER FORECASTER 18 BACKLIGHT 19 USING DIFFERENT DISPLAY WINDOWS 19 PRESSURE WINDOW 19 CLOCK WINDOW 23 SUNRISE SUNSET WINDOW 29 TEMPERATURE AND HUMIDITY WINDOW 32 WIND WINDOW 35 MAINTANANCE 37 TROUBLESHOOTING 38 PRECAUTIONS 38 APPENDIX CITY CODES 39 SPECIFICATIONS 41 FCC STATEMENT 43 DECLARATION OF CONFORMITY 44 STANDARD WAR...

Page 2: ...NSTALLATION The Honeywell Weather Forecaster with Wind Speed TE852W operates at 433MHz radio frequency so no wire installation is required between the main unit receiver and the remote weather sensors transmitters The remote weather sensors include a temperature and humidity sensor and wind speed sensor All data measured by these remote sensors is transmitted to the main unit wirelessly with the o...

Page 3: ...sor Transmission reception range may be affected by trees metal structures and electronic appliances by surrounding building materials and the way how the receiver main unit and transmitters remote weather sensors are positioned The main unit must be placed indoors Place the remote sensor so that it faces the main unit receiver minimizing obstructions such as doors walls and furniture 6 NOTE When ...

Page 4: ... the flat surface or mounted on the wall in vertical position 8 Use the wall mount hardware and screws when mounting the thermo hygrometer sensor on the wall PLACEMENT The remote thermo hygrometer sensor should be placed in the area with a free air circulation and sheltered from the direct sunlight and an extreme weather conditions Ideally place the thermo hygrometer sensor above the natural surfa...

Page 5: ...t if the wind cups sit secure on the wind cups shaft BATTERY INSTALLATION Remove four 4 screws from the battery compartment with a small Phillips screwdriver Open the battery compartment and install 2 AA size alkaline batteries not included matching the polarities shown Replace the battery compartment door and secure the screws MOUNTING Mount the wind speed meter onto a vertical surface using the ...

Page 6: ...wind gust averages and memory Operating range from 100 feet 30 meters up to 328 feet 100 meters 12 Power 2 AA batteries main unit 4 AA batteries remote sensors BATTERY INSTALLATION Remove the battery compartment door located in the table stand on the back of the main unit Insert two 2 AA size batteries according to the polarities shown and replace the battery compartment door When placing the main...

Page 7: ...w If pressure and altitude are not configured during this time the unit will self calibrate in a few minutes and show the default settings for the pressure and altitude sea level and all remote weather sensors readings To set the pressure altitude units and program your altitude use the main unit control panel located on the back FRONT A 14 REAR TOP SIDE A WEATHER AND TIME IN EASY TO READ DIGITS B...

Page 8: ... into the alarm programming mode for selected parameter If depressed and hold in barometric pressure forecast mode allows viewing of the temperature and humidity history charts H WALL MOUNT RECESSED OPENING Keeps the unit on the wall I BATTERY COMPARTMENT Accommodates 2 two UM 3 or AA 1 5V alkaline batteries K SNOOZE LIGHT button Stops all alarms temporarily 16 Activates a backlight for 5 seconds ...

Page 9: ...rmo Hygrometer sensor battery status 18 WIND WINDOW Displays Wind Chill temperature Temperature at place of anemometer Wind speed Wind gust speed Alarm for wind speed and wind gust Remote anemometer battery status CUSTOMAZING YOUR WEATHER FORECASTER It is required to program Pressure parameters during Initial Setup See Pressure and Weather Forecast Mode P Time the date and the weekday language Clo...

Page 10: ...TV or radio station etc OPERATION Press UP or DOWN until the weather forecast icon on the upper left of the display starts flashing 20 SETTING PRESSURE PARAMETERS IMPORTANT During the main unit initial setup after main unit powered up all of the functions in Pressure and Weather Forecast Window will be locked for a short time until the pressure settings are configured The locked display will show ...

Page 11: ...tering the sea level pressure display When the SEA LEVEL is displayed press HISTORY repeatedly viewing the sea level pressure history for the past 24 hours in 1 hour intervals If no buttons are pressed for 5 seconds the unit will automatically 22 return to the default Pressure and Weather Forecast Mode VIEWING PRESSURE TEMPERATURE AND HIMIDITY CHARTS The bar chart in Pressure Window can be configu...

Page 12: ...sted alarms can also be programmed up to 15 minutes ACCESSING CLOCK WINDOW Press UP or DOWN until the clock icon next to the time date display will flash PROGRAMMING YOUR LOCATION IMPORTANT There are two options available for programming a location an auto and manual In case of an auto programming select the closest city code from the codes list programmed in the unit then all necessary location d...

Page 13: ...able and DOWN to disable the DST option Press SET to confirm selection and the year digits will flash Continue setting the year month day calendar format day month or month day time format 12 or 24 hours local hour and minutes using 26 the same technique After programming is complete the display will return to the default Clock Window Note Press and hold SET anytime during the setup to return to t...

Page 14: ...WVB signal through the internal antenna from up to 2 000 miles away Due to the nature of the Earth s ionosphere reception can be limited during the daylight hours The radio controlled clock will search for an alternate station that receives the atomic time signal from the NIST Atomic clock in Boulder Colorado The WWVB tower icon on the unit s display will flash indicating a radio signal reception ...

Page 15: ...ay will start flashing 30 PROGRAMMING YOUR LOCATION In Sunrise Sunset Window press and hold SET until the city code in the Clock Window will flash entering the location programming mode Select the city code closest to your area by pressing the UP or DOWN Refer to P for a list of available codes The corresponding longitude and latitude will be displayed in Sunrise Sunset Window along with the city ...

Page 16: ...for the whole day 32 TEMPERATURE AND HUMIDITY WINDOW The Weather Forecaster supports up to 5 remote thermo hygrometers corresponding to a separate channel of the temperature and relative humidity display The temperature can be displayed in Celsius ºC or Fahrenheit ºF The main unit carries the temperature and humidity sensor and uses this data to calculate an indoors comfort level Wet Comfort or Dr...

Page 17: ...o recall a current temperature for the corresponding channel the upper temperature alert with icon if disabled displays OFF or lower temperature alert with icon if disabled displays OFF 34 Once the above alerts are displayed press the UP or DOWN to enable or disable the corresponding alert PROGRAMMING ALARMS In the Temperature and Humidity Window press ALARM selecting the desired alarm Press and h...

Page 18: ...IND icon on the display starts flashing OPERATING In the Wind Window press the SET button to recall Wind chill temperature with wind speed 36 Temperature at anemometer with wind speed PROGRAMMING UNITS In the Wind Window press and hold SET to set the wind speed units in km h mph m s or knots VIEWING STATISTICS In the Wind Window press the MEM button to recall Current wind speed a daily maximum win...

Page 19: ...cleaner 38 Never use any abrasive cleaning agents and solvents Do not immerse any units with electronic parts in water or under running water WIND METER Check if the wind cups can spin freely and are free from dirt debris and spider webs TROUBLESHOOTING Check here before contacting customer service Issue Symptom Solution Main unit US Atomic Time signal is not received Place unit by the window and ...

Page 20: ...ash SEA 8 SU Vancouver B C Can YVR 8 SU St Louis Mo STL 6 SU Washington D C DCA 5 SU 40 Tampa Fla TPA 5 SU Vancouver Canada VAC 8 SU Toronto Ont Can YTZ 5 SU World Cities City Code Time DST City Code Time DST Addis Ababa ADD 3 NO Cairo Egypt CAI 2 sg Adelaide ADL 9 5 SA Calcutta India as CCU 5 5 NO Algiers Algeria ALG 1 NO Cape Town South CPT 2 NO Amsterdam AMS 1 SE Caracas CCS 4 NO Ankara Turkey ...

Page 21: ...003 inHg 0 1 Hpa 0 08 mmHg Accuracy 0 015 inHg 0 5 Hpa 0 38 mmHg Sampling interval 20 minutes Altitude Compensation Range 657 ft to 16404 ft 200m to 5000 m Temperature Indoor 42 Operating Range 23 F to 122 F 5 C to 50 C Resolution 0 2 F 0 1 C Accuracy 2 F 1 C Sampling Interval 10 seconds Temperature remote Range 40 F to 176 F 40 C to 80 C Resolution 0 2 F 0 1 C Accuracy 2 F 1 C Transmitting Interv...

Page 22: ...ticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to improve or correct turning the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment t...

Page 23: ...stomer Service Hotline 1 866 443 3543 Please direct all returns to the place of the original purchase Should this not be possible contact Hideki Customer Service Hotline for assistance and to obtain a Return Merchandise Authorization RMA Returns without a return authorization will be refused Please retain your original receipt as you may be asked to provide a copy for proof of purchase Hideki Elec...