82
www.honeywell.com/sensing
GSE EN 50047 Compatible
Safety 3 Conduit Metal
Standard
conduit
thread
60 /
2.37
4 /
0.16
52 /
2.05
57 /
2.24
65 /
2.56
13,75 /
0.54
2,5 /
0.1
R
2,15 /
0.08
3 /
0.12
20 /
0.79
22 /
0.87
40 /
1.57
42 /
1.65
23,8 /
0.94
ø 23 /
ø 0.9
30 /
1.18
12 /
0.47
12,5 /
0.49
24,75 /
0.97
Mechanical life:
up to 1 million
Sealing:
IP 66, NEMA/UL 1, 4, 12, 13
Operating temperature:
-25 °C to 85 °C
(-13 °F to 185 °F)
Approvals:
IEC/EN 60947-5-1
AC15 A300
DC13 Q300
UL, CSA, BG
ACTUATED SWITCHES
Rotated 90° to the left
from center
70 /
2.76
45 /
1.77
104 /
4.09
CONTACT
CONDUIT
REFERENCE
2NC/2NO, BBM
½ in NPT
GSEA44S1
3NC/1NO, BBM
½ in NPT
GSEA46S1
4NC, low energy
20 mm
GSEC41S1
Rotated 90° either direction from
center
12,5 /
0.49
24,8 /
0.97
2 /
0.08
11,5 /
0.45
5,1 /
0.20
45 /
1.77
70 /
2.76
28 /
90 min.
90 min.
CONTACT
CONDUIT
REFERENCE
2NC/2NO, BBM
½ in NPT
GSEA44S2
Rotated 90° to the right
from center
180 MIN
CONTACT
CONDUIT
REFERENCE
2NC/2NO, BBM
½ in NPT
GSEA44S3
SAFETY SWITCHES
Summary of Contents for Switches and Sensors
Page 6: ...4 www honeywell com sensing Blank page ...
Page 28: ...26 www honeywell com sensing COMPACT LIMIT SWITCHES Blank page ...
Page 56: ...54 www honeywell com sensing Blank page ...
Page 70: ...68 www honeywell com sensing Blank page ...
Page 94: ...92 www honeywell com sensing Blank page ...
Page 118: ...116 www honeywell com sensing LINEAR AND ROTARY POSITION Blank page ...