24CE/924CE Series

OPTIONS

Side rotary

PT

PT

OT

OT

DT

DT

North America/Global

CABLE LENGTH CONTACT

REFERENCE

3 ft

1NC,  BBM

924CE16-S3

9 ft

1NC, BBM

924CE16-S9

3 ft

1NC, MBB

924CE16-T3

3 ft

1NC

924CE16-Y3

9 ft

1NC

924CE16-Y9

Europe

CABLE LENGTH CONTACT

REFERENCE

1 m

1NC/1NO, BBM

24CE16-S1

1 m

1NC

24CE16-Y1

6 m

1NC

24CE16-Y6

Top pin plunger

17,5

 max.

ø10

North America/Global

CABLE LENGTH CONTACT

OPTION

REFERENCE

3 ft

1NC, BBM

924CE1-S3

6 ft

1NC, BBM

924CE1-S6

9 ft

1NC, BBM

924CE1-S9

25 ft

1NC, MBB

side exit

924CE1-T25A

3 ft

1NC, MBB

924CE1-T3

3 ft

1NC, MBB

side exit

924CE1-T3A

6 ft

1NC, MBB

side exit

924CE1-T6A

9 ft

1NC, MBB

924CE1-T9

9 ft

1NC, MBB

side exit

924CE1-T9A

3 ft

1NC

924CE1-Y3

9 ft

1NC

924CE1-Y9

Europe

CABLE LENGTH CONTACT

OPTION

REFERENCE

12 m

1NC/1NO, BBM

low temperature

24CE1-S12B

2 m

1NC/1NO, BBM

24CE1-S2

2 m

1NC/1NO, BBM

side exit

24CE1-S2A

2 m

1NC/1NO, BBM

low temperature

24CE1-S2B

3 m

1NC/1NO, BBM

24CE1-S3

6 m

1NC/1NO, BBM

24CE1-S6

1 m

1NC

side exit

24CE1-Y1A

2 m

1NC

24CE1-Y2

3 m

1NC

24CE1-Y3

Top pin plunger, boot sealed

24,3

 max.

ø7,1

North America/Global

CABLE LENGTH CONTACT

REFERENCE

6 ft

1NC/1NO, BBM

924CE18-S6

Adjustable plunger

26,8

(1.05)

North America/Global

CABLE LENGTH CONTACT

OPTION

REFERENCE

3 ft

1NC/1NO, BBM

low temperature

924CE19-S3L1

Top roller plunger, parallel

30,3

 max.

ø12,4

North America/Global

CABLE LENGTH CONTACT

OPTION

REFERENCE

15 ft

1NC, BBM

924CE2-S15

21 ft

1NC, BBM

924CE2-S21

3 ft

1NC, BBM

924CE2-S3

6 ft

1NC, BBM

924CE2-S6

6 ft

1NC, BBM

side exit

924CE2-S6A

9 ft

1NC, BBM

924CE2-S9

25 ft

1NC, MBB

924CE2-T25

25 ft

1NC, MBB

side exit

924CE2-T25A

3 ft

1NC, MBB

924CE2-T3

6 ft

1NC, MBB

924CE2-T6

9 ft

1NC, MBB

924CE2-T9

3 ft

1NC

924CE2-Y3

9 ft

1NC

924CE2-Y9

Europe

CABLE LENGTH CONTACT

OPTION

REFERENCE

1 m

1NC/1NO, BBM

24CE2-S1

2 m

1NC/1NO, BBM

24CE2-S2

2 m

1NC/1NO, BBM

side exit

24CE2-S2A

2 m

1NC/1NO, BBM

low temperature

24CE2-S2B

3 m

1NC/1NO, BBM

24CE2-S3

6 m

1NC/1NO, BBM

24CE2-S6

2 m

1NC/1NO, MBB

24CE2-T2

1 m

1NC

24CE2-Y1

2 m

1NC

24CE2-Y2

2 m

1NC

side exit

24CE2-Y2A

4 m

1NC

24CE2-Y4

6 m

1NC

side exit

24CE2-Y6A

COMPACT LIMIT SWITCHES

Summary of Contents for Switches and Sensors

Page 1: ... switches Heavy duty switches Compact switches Precision switches Hazardouslocationswitches Safety switches Relays Position products Ultrasonicdistancesensors Pressure sensors and Product solutions on the Interactive Catalogue July 2003 ...

Page 2: ... in the instructions supplied with each product Failure to comply with these instructions could result in death or serious injury WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury Does not apply to 24CE 924CE Series page 23 GSS Series page 80 GK Series pages 78 83 85 or CPS ...

Page 3: ...witches Rugged cast aluminium housed switches sealed for wash down applications Momentary or maintained contacts right or left hand actuators 3 hole mounting HDLS Series Page Heavy Duty Limit Switches Suitable for special applications in corrosive environments Housed in a rugged die cast zinc body and epoxy coated for protection they are available with a range of switching and head options Explosi...

Page 4: ...emergency stops We are a recognized technology leader in the development and manufacture of pressure and position sensing transducers and controls We use the latest in manufacturing technology to produce hundreds of thousands of transducers a year Millions of units are currently performing in a multitude of continuous duty applications around the world where they typically outlast the systems they...

Page 5: ... supplier Delivering excellence in system critical sensing solutions A system is critical if the quality reliability delivery and customer service associated with a component part is essential to the performance of the operation or end product If a sensor or a switch is critical to the performance cost effectiveness delivery or safety of a product or operation then it s systems critical It is ther...

Page 6: ...4 www honeywell com sensing Blank page ...

Page 7: ...rcuitries and electrical ratings Enclosed switches are known for high precision and low cost Limit Switches are especially rugged and well sealed Explosion proof switches are designed for use in hazardous locations The Honeywell switches featured here are all proven in a broad range of Industrial applications machine tools packaging machinery lifting gear presses and construction machinery More in...

Page 8: ...ypical application where the switch is used The contact rating Designation relates to the Utilization Categories and defines the conventional thermal current Ith a rated operational current Ie A at rated operational voltages Ue and the VA rating Actuators A range of actuators is available for limit switches Illustrations of actuator types available from this catalogue are shown at the beginning of...

Page 9: ...water 8 protected against the effects of continuous immersion in water NEMA Classification USA NEMA National Electrical Manufacturer s Association prepares standards which define a product process or procedure with reference to one or more of the following nomenclature composition construction dimensions tolerances safety operating characteristics performance quality electrical rating testing and ...

Page 10: ...ial Plastic Termination Insulation Displacement Terminals IDT Switching options SPDT Single Pole Double Throw Snap action contacts 1NC 1NO Zb OPTIONS Side rotary plastic roller REFERENCE EVN2000A Top roller plunger parallel REFERENCE EVN2000C Top pin plunger REFERENCE EVN2000B Top roller plunger perpendicular REFERENCE EVN2000D Operating characteristics Actuator Operating Free Pretravel Travel to ...

Page 11: ... 2 0 8 nylon roller R 3 0 M4 arm 56 0 3 21 0 2 28 M3x6 cover screw M4 arm fixing nut 12 5 402 18 5 64 2 M5 P 0 8 tapped 14 7 5 0 2 15 1 38 1 25 2 M3x23 20 4 0 3 PT 20 max cover screw Standard type 18 dia x7 through 360 827 008 1 102 2 205 012 492 holes rotated and locked 1 622 031 1 425 031 10 2 728 803 012 2 520 551 1 5 984 594 295 008 mounting holes 2 M5 P 0 8 tapped mounting holes 2 4 1 dia 0 2...

Page 12: ...ctuated switches Pretravel max PT 1 5 mm 0 060 in Overtravel min OT 4 0 mm 0 158 in Differential travel max DT 0 7 mm 0 028 in Operating force max OF 8 83 N 2 lb Top pin plunger mounting holes 402 2 M3x23 cover screw 2 4 1 0 2 mounting holes 2 M5 P 0 8 tapped 7 276 in depth M3x6 cover screw 64 14 7 5 0 2 15 1 25 20 4 0 3 118 26 5 56 0 3 21 0 2 28 stainless steel plunger mounting holes 2 M5 P 0 8 t...

Page 13: ... 2 56 0 3 14 64 7 5 0 2 157 28 20 4 0 3 25 15 1 5 8 dia 3 dia Nylon rod 41 5 100 1 5 2 M3x23 M3x6 cover screw 7 276 in depth mounting holes 2 M5 P 0 8 tapped PT 50 max Standard type cover screw 1 634 3 937 059 2 205 012 1 102 827 008 10 2 118 228 803 012 4 2 520 551 295 008 984 594 2 M5 P 0 8 tapped mounting holes mounting holes 2 4 1 dia 0 2 0 mounting holes 161 dia 0 008 0 REFERENCE SZL VL F Coi...

Page 14: ... 0 12 in 50 5 mm 2 00 in 31 0 mm 1 22 in 0 65 2 mm 2 57 in 39 25 mm 1 55 in __ __ 4 5 mm 0 18 in 5 0 mm 0 20 in 8 3 mm 0 33 in 6 9 mm 0 27 in Operating characteristics IEC947 5 1 EN60947 5 1 Designation Rated operational current Ie A VA Utilization Category at rated operational voltage Ue rating 120V 240V 380V 480V 500V 600V Make Break AC15 A600 6 3 1 9 1 5 1 4 1 2 7200 720 AC15 A300 6 3 7200 720 ...

Page 15: ... adjustable roller Plastic roller CONTACT CONDUIT REFERENCE SPDT in NPT GLAA01A2A DPDT in NPT GLAA20A2A SPDT PG 13 5 GLAB01A2A DPDT PG 13 5 GLAB20A2A SPDT 20 mm GLAC01A2A Metal roller CONTACT CONDUIT REFERENCE SPDT in NPT GLAA01A2B DPDT in NPT GLAA20A2B SPDT PG 13 5 GLAB01A2B DPDT PG 13 5 GLAB20A2B SPDT 20 mm GLAC01A2B DPDT 20 mm GLAC20A2B Side rotary adjustable metal rod 34 1 34 41 1 61 3 2 13 75...

Page 16: ...T GLAA01K8C DPDT in NPT GLAA20K8C SPDT PG 13 5 GLAB01K8C GLC EN 50047 Standard metal body 24 75 0 97 14 5 57 30 1 18 conduit thread PG 13 5 22 87 20 78 3 12 2 15 08 R 55 2 16 30 5 1 20 3 5 0 138 15 25 600 Mechanical life up to 10 million Sealing IP 66 NEMA 1 4 12 13 Operating temperature 25 C to 85 C 13 F to 185 F Approvals IEC EN 60947 5 1 AC15 A300 DC13 Q300 UL CSA CE Switching options SPDT Sing...

Page 17: ... Top pin plunger OP DT 18 0 5 709 Ø 9 9 390 CONTACT CONDUIT REFERENCE SPDT in NPT GLCA01B SPDT PG 13 5 GLCB01B SPDT 20 mm GLCC01B Top roller plunger 31 0 1 22 FP CONTACT CONDUIT REFERENCE SPDT in NPT GLCA01C SPDT PG 13 5 GLCB01C SPDT 20 mm GLCC01C Top roller lever Ø 39 2 1 54 FP CONTACT CONDUIT REFERENCE SPDT in NPT GLCA01D SPDT PG 13 5 GLCB01D SPDT 20 mm GLCC01D Wobble coil actuator Mechanical li...

Page 18: ...tal rod CONTACT CONDUIT REFERENCE SPDT in NPT GLDA01A4J SPDT PG 13 5 GLDB01A4J Top pin plunger CONTACT CONDUIT REFERENCE SPDT in NPT GLDA01B SPDT PG 13 5 GLDB01B SPDT 20 mm GLDC01B Top roller plunger CONTACT CONDUIT REFERENCE SPDT in NPT GLDA01C SPDT PG 13 5 GLDB01C SPDT 20 mm GLDC01C Top roller lever CONTACT CONDUIT REFERENCE SPDT in NPT GLDA01D SPDT PG 13 5 GLDB01D SPDT 20 mm GLDC01D Wobble coil...

Page 19: ...CONTACT CONDUIT REFERENCE SPDT PG 13 5 GLEB01A4J DPDT PG 13 5 GLEB24A4J Top pin plunger 18 0 709 CONTACT CONDUIT REFERENCE SPDT in NPT GLEA01B DPDT in NPT GLEA24B SPDT PG 13 5 GLEB01B DPDT PG 13 5 GLEB24B Top roller plunger 31 0 1 23 Ø 12 4 0 49 FP CONTACT CONDUIT REFERENCE SPDT in NPT GLEA01C DPDT in NPT GLEA24C SPDT PG 13 5 GLEB01C DPDT PG 13 5 GLEB24C DPDT 20 mm GLEC24C Top roller lever 39 2 1 ...

Page 20: ...Operating temperature 10 C to 70 C 14 F to 160 F Approvals UL CSA CE Termination Cable gland Operating force max OF 11 76 N 2 64 lb Pretravel max PT 1 5 mm 0 060 in Overtravel min OT 3 0 mm 0 118 in Differential travel max DT 0 10 mm 0 004 in Electrical rating contact SL1 5A 125 250 Vac Silver SL1 K 0 1 A 125 Vac 0 1 A 30 Vdc Gold clad cross point Switching options SPDT Single Pole Double Throw Sn...

Page 21: ...plunger long perpendicular 41 4 OP CONTACT REFERENCE Silver SL1 K Gold clad cross point SL1 KK Top roller lever Operating force max OF 3 92 N 0 88 lb Pretravel max PT 2 0 mm 0 079 in Overtravel min OT 4 0 mm 0 158 in Differential travel max DT 0 3 mm 0 012 in CONTACT REFERENCE Silver SL1 P Gold clad cross point SL1 PK COMPACT LIMIT SWITCHES ...

Page 22: ...E 0 C to 105 C 32 F to 221 F Approvals 14CE CE 914CE CSA UL CE AC14 D300 DC13 R300 Operating force OF 11 8 N 2 65 lb max Pretravel PT 1 8 mm 0 71 in max Overtravel OT 3 0 mm 0 118 in min Differential travel DT 0 1mm 0 004 in max Contact Rating 9 14CE Silver A 9 14CE G Gold B 9 14CE Q AQ AQ1 Silver C Connection Harmonised CENELEC 4 x 0 75 mm2 cable 14CE SJTO 4 x 0 75 mm2 18 AWG cable 914CE Connecto...

Page 23: ...FERENCE 3 ft cable bottom exit 914CE66 3 6 ft cable bottom exit 914CE66 6 EUROPE REFERENCE 1 metre cable bottom exit 14CE66 1 2 metre cable bottom exit 14CE66 2 Adjustable plunger OP NORTH AMERICA GLOBAL REFERENCE 3 ft cable bottom exit 914CE19 3 9 ft cable bottom exit 914CE19 9 Manually operated OP 27 4 1 08 Operating force OF 9 0 N 2 02 lb NORTH AMERICA GLOBAL REFERENCE 6 ft cable bottom exit 91...

Page 24: ...H AMERICA GLOBAL REFERENCE 3 ft cable bottom exit 914CE29 3 6 ft cable bottom exit 914CE29 6 Side rotary and wobble actuated switches OPTIONS Rotary motion actuating lever not included use any LSZ51 LSZ52 LSZ54 LSZ55 or LSZ61 Series shown on page Operating torque 0 3 Nm 2 66 in lb Pretravel PT 30 max Overtravel OT mm 40 min Differential travel 3 NORTH AMERICA GLOBAL REFERENCE 3 ft cable bottom exi...

Page 25: ...tion with cams on doors with hinges or our fixed side rotary 24CE16 style for detection of sliding doors Also available are a range of panel mounting or top mounting versions to ensure that small space or difficult mounting can be simply achieved Several contact arrangements are available Mechanical life 10 million Sealing standard type IP66 with boot seal type IP67 Operating temperature 24CE 0 C ...

Page 26: ...3 6 m 1NC 1NO BBM 24CE1 S6 1 m 1NC side exit 24CE1 Y1A 2 m 1NC 24CE1 Y2 3 m 1NC 24CE1 Y3 Top pin plunger boot sealed 24 3 max ø7 1 North America Global CABLE LENGTH CONTACT REFERENCE 6 ft 1NC 1NO BBM 924CE18 S6 Adjustable plunger 26 8 1 05 North America Global CABLE LENGTH CONTACT OPTION REFERENCE 3 ft 1NC 1NO BBM low temperature 924CE19 S3L1 Top roller plunger parallel 30 3 max ø12 4 North Americ...

Page 27: ...lunger parallel panel mounted 27 7 1 75 North America Global CABLE LENGTH CONTACT REFERENCE 15 ft 1NC BBM 924CE28 S15 Europe CABLE LENGTH CONTACT REFERENCE 2 m 1NC 1NO BBM 24CE28 S2 COMPACT LIMIT SWITCHES Top roller plunger perpendicular 30 3 max ø12 4 North America Global CABLE LENGTH CONTACT REFERENCE 3 ft 1NC BBM 924CE3 S3 6 ft 1NC BBM 924CE3 S6 9 ft 1NC BBM 924CE3 S9 9 ft 1NC MBB 924CE3 T9 Eur...

Page 28: ...26 www honeywell com sensing COMPACT LIMIT SWITCHES Blank page ...

Page 29: ... C 20 F to 160 F High 29 C to 121 C 20 F to 250 F Approvals LS L UL CSA Contacts Electrical ratings A B C D E Silver Cadmium Oxide 1 Electrical ratings F G Fine Silver Switching options SPDT Single Pole Double Throw Snap action contacts 1NC 1NO 4 1 3 2 Electrical ratings A 10 A 120 240 or 480 Vac 1 3 hp 120 Vac hp 240 Vac 0 8 A 115 Vdc 0 4 A 230 Vdc 0 1 A 550 Vdc Pilot Duty 600 Vac max B 10 A 120 ...

Page 30: ...AL RATING REFERENCE A 1LS1 F 1LS1 L 20 mm A 1LS1 4C Low PT OF B 1LS131 Low PT B 1LS19 Low PT 20 mm B 1LS19 4C High temperature A 1LS243 High temperature 20 mm A 1LS243 4C Indicator light C 1LS501 Low OF A 1LS6 Adjustable roller lever Operating force max OF Standard 13 3 N 3 0 lb Low 5 0 N 18 oz Pretravel max PT Standard 20 Low 5 Overtravel min OT 30 Differential travel max DT Standard 12 Low 4 Swi...

Page 31: ...S23 Low OF PT B 1LS56 Low PT B 1LS9 Maintained contact CONDUIT ELECTRICAL RATING REFERENCE A 6LS2 F 6LS2 L Adjustable rod Operating force max OF Standard 1 39 N 5 oz Low 0 83 Nm 3 oz Pretravel max PT Standard 20 Low 5 Overtravel min OT 30 Differential travel max DT Standard 12 Low 4 Switching options SPDT Lever Aluminium rod CONDUIT ELECTRICAL RATING REFERENCE A 1LS10 F 1LS10 L 20 mm A 1LS10 4C Lo...

Page 32: ...N 7 lb Pretravel max PT 1 65 mm 0 065 in Overtravel min OT 5 56 mm 0 219 in Differential travel max DT 0 51 mm 0 020 in Switching options SPDT CONDUIT ELECTRICAL RATING REFERENCE A 5LS1 F 5LS1 L 20 mm A 5LS1 4C Side pin plunger Operating force max OF 40 03 N 9 lb Pretravel max PT 2 8 mm 0 110 in Overtravel min OT 6 35 mm 0 25 in Differential travel max DT 1 02 mm 0 040 in Switching options SPDT CO...

Page 33: ...550 0 10 Ø 4 80 0 08 0 189 0 003 CONDUIT ELECTRICAL RATING REFERENCE D 8LS1 G 8LS1 L 20 mm D 8LS1 4C Spring rod CONDUIT ELECTRICAL RATING REFERENCE D 8LS3 20 mm D 8LS3 4C Coil spring Ø 6 17 0 08 0 264 0 003 141 0 2 54 5 550 0 10 CONDUIT ELECTRICAL RATING REFERENCE D 8LS152 20 mm D 8LS152 4C Steel wire Operating force max OF 0 28 N 1 oz Pretravel max PT 63 5 mm 2 5 in 191 3 7 53 CONDUIT ELECTRICAL ...

Page 34: ...ts Silver Electrical ratings A 11 A 125 Vac 250 Vac or 277 Vac B 5 A 125 Vac 250 Vac or 277 Vac Switching options SPDT Single Pole Double Throw Snap action contacts 1NC 1NO Plunger actuated switches OPTIONS Top pin plunger 58 7 2 31 73 5 2 89 35 1 1 38 15 5 0 61 17 5 0 69 4 9 0 19 44 5 1 75 65 28 2 57 Ø 7 1 0 28 Max 14 3 0 56 9 5 0 38 Conduit thread Operating force max OF 12 23 N 44 oz Differentia...

Page 35: ...REFERENCE POSITION RATING Left B BFL1 BL2 Right B BFR1 BL2 Wobble actuated switches Operating force max OF 1 95 N 7 oz OPTIONS Coil spring 58 7 2 31 73 5 2 89 35 1 1 38 15 5 0 61 17 5 0 69 4 9 0 19 44 5 1 75 169 9 6 69 Ø 7 1 0 28 Max 14 3 0 56 9 5 0 38 ACTUATOR ELECTRICAL REFERENCE POSITION RATING Left A BFL1 AW1 Left B BFL1 BW1 Right B BFR1 BW1 Plastic 58 7 2 31 73 5 2 89 35 1 1 38 15 5 0 61 17 5...

Page 36: ... long term accuracy of the switch Conduit in 14 NPT Sealing E6 NEMA 1 V6 NEMA 1 3 Operating temperature Standard 32 C to 71 C 25 F to 160 F Low 40 C to 71 C 40 F to 160 F Approvals UL CSA CE Contacts Electrical ratings A B C Silver Electrical rating D Gold Switching options SPDT Single Pole Double Throw Snap action contacts 1NC 1NO DPDT Double Pole Double Throw Snap action contacts 2NC 2NO Electri...

Page 37: ...oz to 40 oz Pretravel max PT SPDT 0 38 mm 0 015 in DPDT 3 81 mm 0 150 in Overtravel min OT SPDT 5 56 mm 0 219 in DPDT 2 24 mm 0 088 in Differential travel max DT SPDT 0 05 mm 0 002 in DPDT 1 52 mm 0 060 in Side mount CONTACT ELECTRICAL RATING REFERENCE SPDT A BZE6 2RQ DPDT B DTE6 2RQ Flange mount CONTACT ELECTRICAL RATING REFERENCE SPDT A BZV6 2RQ PRECISION LIMIT SWITCHES Top roller plunger parall...

Page 38: ... mount CONTACT ELECTRICAL RATING REFERENCE SPDT A BZV6 2RQ81 Roller arm adjustable Side mount without boot seal Flange mount with boot seal Operating temperature Standard 32 C to 71 C 25 F to 160 F Low 40 C to 71 C 40 F to 160 F Roller Steel With boot seal Operating Force max OF 2 78 N to 5 56 N 10 oz to 20 oz Pretravel max PT 4 78 mm 0 188 in Overtravel min OT 5 56 mm 0 219 in Differential travel...

Page 39: ...nt SPDT A BZV6 2RN62 Without boot seal Operating force max OF 0 56 N to 1 39 N 2 oz to 5 oz CONTACT ELECTRICAL RATING REFERENCE Side mount SPDT A BZE6 2RQ62 Flange mount SPDT A BZV6 2RQ62 Manual palm button Side mount with boot seal 36 6 1 44 18 3 0 72 31 8 1 25 1 2 14 NPSM 5 THREADS MIN 78 5 3 09 44 4 1 75 77 2 3 04 22 6 0 89 4 3 0 17 Ø 2 41 4 1 63 38 1 1 50 25 4 1 00 54 1 2 13 With boot seal Ope...

Page 40: ...l SPDT Maintained C BZE6 RQX2 Top roller plunger Side mount without boot seal 56 69 2 232 53 19 2 094 Reset FP 19 0 0 75 25 4 1 00 22 6 0 89 Ø 15 75 0 62 Ø 25 4 1 0 40 08 1 58 14 22 0 56 23 19 0 913 69 59 2 74 Ø 12 7 0 50 x 4 6 0 18 Wide roller Side mount with boot seal Side mount Operating force max OF With boot seal 3 34 N to 15 57 N 12 oz to 56 oz Without boot seal 1 67 N to 2 64 N 6 oz to 9 5 ...

Page 41: ...4 5 1 75 3 8 0 15 Pretravel 13 97 0 55 25 4 1 00 5 84 0 23 4 06 0 16 12 7 0 50 Ø 14 73 0 58 OP Ø 12 7 x 4 5 wide roller Ø 0 50 x 0 18 76 40 3 01 CONTACT CONDUIT ELECTRICAL RATING REFERENCE SPDT PG 13 5 BZE7 2RQ8 PG Top roller plunger perpendicular without boot seal 44 53 1 75 0 38 0 015 Pretravel 13 97 0 55 25 4 1 00 5 84 0 23 4 06 0 16 12 7 0 50 Ø 14 73 0 58 OP Ø 12 7 x 4 57 0 50 x 0 18 76 40 3 0...

Page 42: ...to 71 C 25 F to 160 F Conduit in 14 NPT Contacts Silver Electrical ratings B UL CSA Rating 10 A 125 or 250 Vac 0 3 A 125 Vdc 0 15 A 250 Vdc D UL CSA Rating 20 A 125 250 or 480 Vac 1 Hp 125 Vac 2 Hp 250 Vac A 125 Vdc A 250 Vdc Lamp Load 10 A 125 Vac Switching options D SPDT Single Pole Double Throw Snap action contacts 1NC 1NO B DPDT Double Pole Double Throw Snap action contacts 2NC 2NO Momentary c...

Page 43: ...m 0 125 in Differential travel max DT BAF 0 26 mm 0 010 in DTF 1 53 mm 0 060 in Operating position OP BAF 64 69 mm 2 547 in DTF 63 88 mm 2 515 in ACTUATOR POSITION CONTACT ELECTRICAL RATING REFERENCE Right SPDT D BAF1 2RQ9 RH Left SPDT D BAF1 2RQ9 LH Right DPDT B DTF2 2RQ9 RH Left DPDT B DTF2 2RQ9 LH Roller arm adjustable With boot seal Operating force max OF BAF 8 90 N 2 0 lb DTF 11 1 N 2 5 lb Pr...

Page 44: ...8 LH Maintained contact reset switches Top pin plunger Right hand With boot seal Operating force max OF 7 79 N 1 75 lb Pretravel max PT 2 39 mm 0 094 in Overtravel min OT 5 56 mm 0 219 in ACTUATOR POSITION CONTACT ELECTRICAL RATING REFERENCE Right Maintained SPDT D BAF1 3RNX1 Roller arm adjustable 82 6 3 25 101 6 4 00 With boot seals on roller arm and plunger Operating force max OF 6 67 N 1 5 lb P...

Page 45: ...08 27 4 1 08 158 5 6 24 32 5 1 28 20 6 0 81 101 6 4 00 Ø 7 1 0 28 Ø 6 9 0 27 3 1 2 14 NPT Threads With boot seals on wobble stick and plunger Pretravel max PT 15 ACTUATOR POSITION CONTACT ELECTRICAL RATING REFERENCE Right Maintained SPDT D BAF1 3CN18X1 PRECISION LIMIT SWITCHES ...

Page 46: ...eals also promote longer operating life for rotary actuacted HDLS switches in applications where the temperatures are normally 12 C to 121 C 10 F to 250 F If prewired with cable temperature limits are 105 C 221 F dry and 60 C 140 F wet To order a fluorocarbon FC sealed switch insert the additional letters Y and C as in the following example LSA1A standard side rotary plug in switch LSYAC1A complet...

Page 47: ...45 www honeywell com sensing HEAVY DUTY LIMIT SWITCHES Operating temperatures Environmental seal performance ...

Page 48: ...ntary action The momentary action listings shown are factory assembled with the head adjusted for both clockwise CW and counterclockwise CCW operation The shaft of side rotary heads face the front label side of switch Actuation direction A simple field adjustment converts switch to accept actuation from one or both directions For ready reference adjustment instructions are cast into the internal l...

Page 49: ...travel 5 max Differential travel SPDT 3 max DPDT 4 max Overtravel 70 min Plug in CONTACT CONDUIT ELECTRICAL RATING REFERENCE SPDT A LSU1A SPDT C LSU1E DPDT in B LSU2B DPDT B LSU6B DPDT C LSU6S Non plug in CONTACT CONDUIT ELECTRICAL RATING REFERENCE SPDT A LSU3K DPDT in B LSU4L Side rotary additional circuitry action The following listings sequential centre neutral and maintained switches are assem...

Page 50: ...rface Other options are available Contact Honeywell for more information Approvals NEMA 1 3 4 4X 6 6P 12 13 UL CSA CE Conduit in 14 NPT Contacts Electrical ratings A B Silver Electrical rating C Gold Switching options Snap action contacts SPDT DPDT SPDT Double Break DPDT Double Break Top plungers momentary action Pretravel 1 78 mm 0 07 in max Differential travel SPDT 0 38 mm 0 015 in max DPDT 0 51...

Page 51: ...RENCE SPDT A LSF3K DPDT B LSF7L Adjustable side roller plunger Operating point 41 0 mm to 47 4 mm 1 615 in to 1 865 in Plug in CONTACT ELECTRICAL RATING REFERENCE SPDT A LSW1A SPDT C LSW1E DPDT B LSW6B DPDT C LSW6S Non plug in CONTACT ELECTRICAL RATING REFERENCE SPDT A LSW3K DPDT B LSW7L Side plunger maintained circuitry LSG contact transfer is maintained after either plunger is operated Operation...

Page 52: ... max Plug in CONTACT ELECTRICAL RATING REFERENCE SPDT A LSJ1A 7M DPDT B LSJ6B 7M Non plug in CONTACT ELECTRICAL RATING REFERENCE SPDT A LSJ3K 7M DPDT B LSJ7L 7M Cable Pretravel approx Radius 38 0 mm 1 5 in Operating force 1 95 N 7 0 oz max Plug in CONTACT ELECTRICAL RATING REFERENCE SPDT A LSJ1A 7N DPDT B LSJ6B 7N Non plug in CONTACT ELECTRICAL RATING REFERENCE SPDT A LSJ3K 7N DPDT B LSJ7L 7N Cat ...

Page 53: ...rsions 12 C to 121 C 10 F to 250 F Cable length 3 658 m 12 ft Contacts Electrical ratings A B Silver Switching options Snap action contacts SPDT DPDT Wiring diagrams Numbers Connectors Colours Cables Single Pole Double Pole Side rotary actuated switches Levers Levers for side rotary types are ordered separately see pages 69 71 for details OPTIONS Standard Pretravel 15 max Differential travel SPDT ...

Page 54: ...83 mm 0 19 in min Operating force 17 8 N m 4 lb max Top pin plunger CONTACT TERMINATION ELECTRICAL RATING REFERENCE SPDT Cable A LSYCC3KP FP DPDT Cable B LSYCC4LX FP SPDT 5 pin Connector A LSYCC3KQ FP DPDT 9 pin Connector B LSYCC7LR FP Top roller plunger CONTACT TERMINATION ELECTRICAL RATING REFERENCE SPDT Cable A LSYDC3KP FP DPDT Cable B LSYDC4LX FP SPDT 5 pin Connector A LSYDC3KQ FP DPDT 9 pin C...

Page 55: ... Pretravel 9 max Differential travel SPDT 3 max DPDT 4 max Overtravel 60 min CONTACT ELECTRICAL RATING REFERENCE SPDT A LS2H4K DPDT B LS2H4L Centre neutral Pretravel 18 max Differential travel DPDT 10 max Overtravel 57 min CONTACT ELECTRICAL RATING REFERENCE DPDT B LS2M4N Plunger actuated switches OPTIONS Top roller plunger Pretravel 1 78 mm 0 07 in max Differential travel 0 38 mm 0 015 in max Ove...

Page 56: ...54 www honeywell com sensing Blank page ...

Page 57: ...this listing Atmospheres containing hydrogen or manufactured gas Group C atmospheres containing diethyl ether ethylene or cyclopropane Group D Atmospheres containing gasoline hexane butane naptha propane acetone toluene or isoprene Division 1 Locations in which hazardous agents are present under normal operating conditions Division 2 Locations in which hazardous agents may be present only in case ...

Page 58: ... Operating temperature 0 C to 70 C 32 F to 158 F Approvals CE PTB 98 ATEX 1064 X EExd IIC T6 Category II 2 G AC14 D300 DC13 R300 Operating force OF 11 8 N max Pretravel PT 1 8 mm 0 71 in max Overtravel OT 3 0 mm 0 118 in min Differential travel DT 0 1mm 0 004 in max Contacts Standard Silver G Gold Connection Harmonised CENELEC 4 x 0 75 mm2 cable Switching options SPDT Single Pole Double Throw Snap...

Page 59: ...0014 EN 50018 EN 50281 1 1 KEMA 00 ATEX 2103 X EExd IIC T6 Category II 2 GD AC15 DC13 Contacts Silver Connection 5 metre HO5VV F 3 x 0 75 mm2 cable Switching options SPDT Single Pole Double Throw Snap action contacts 1NC 1NO BLACK BROWN BLUE OPTIONS Side rotary roller lever Overtravel min OT 6 0 mm 0 0 236 in Differential travel max DT 8 Operating position max PT 26 REFERENCE GXE51A1B Top pin plun...

Page 60: ... 125 250 or 480 Vac 1 8 Hp 125 Vac Hp 250 Vac A 125 Vdc A 250 Vdc B UL CSA Rating 20 A 125 250 or 480 Vac 10 A 125 Vac L 1 Hp 125 Vac 2 Hp 250 Vac A 125 Vdc A 250 Vdc C UL CSA Rating 10 A 125 or 250 Vac 0 3 A 125 Vdc 0 15 A 250 Vdc D UL CSA Rating 10 A 125 250 or 480 Vac A 125 Vdc A 250 Vdc E UL Rating 1 A 125 Vac Switching options SPDT DPDT Single Pole Double Throw Double Pole Double Throw Snap a...

Page 61: ...Preleaded with 0 91 m 3 ft leadwire Operating force max OF Clockwise CW 2 22 N to 6 67 N 0 5 lb to 1 5 lb Counter clockwise CCW 12 2 N 2 75 lb Pretravel max PT 6 35 mm 0 250 in Overtravel max OT 25 Differential travel max DT 2 77 mm 0 109 in 4 Sealing NEMA Class 1 Group B ACTUATION CONTACT ELECTRICAL RATING REFERENCE CW DPDT C EXD AR 3 CCW DPDT C EXD AR30 3 Hermetically sealed Operating force max ...

Page 62: ...ce max OF Electrical rating A C 13 34 N 3 0 lb Electrical rating B 8 90 N 2 lb Pretravel max PT Electrical rating A 1 98 mm 0 078 in Electrical rating B 1 27 mm 0 050 in Electrical rating C 3 96 mm 0 156 in Overtravel min OT Electrical rating A 4 78 mm 0 188 in Electrical rating B 3 18 mm 0 125 in Electrical rating C 3 48 mm 0 141 in Differential travel max DT Electrical rating A 0 10 mm 0 004 in ...

Page 63: ...mm 0 109 in Overtravel min OT Electrical rating D 4 78 mm 0 188 in Electrical rating B 3 18 mm 0 125 in Differential travel max DT Electrical rating D 0 10 mm 0 004 in Electrical rating B 0 23 mm 0 009 in CONTACT ELECTRICAL RATING REFERENCE SPDT D EX N15 Class 1 Group B SPDT B EXA N Manually actuated Operating force max OF 11 1 N 2 5 lb CONTACT ELECTRICAL RATING REFERENCE SPDT A EX AR50 EXPLOSION ...

Page 64: ... Div 1 Groups B 16CX 24CX 26CX and 84CX only C and D and Class II Groups E F and G Operating temperature 25 C to 85 C 13 F to 185 F Approvals UL CSA CX E only ATEX EExd IIC T6 Category II 2 GD Housing Aluminium 80CX Bronze Conduit in 14NPT Contacts A C D Silver F Gold Electrical Ratings A UL CSA Rating L96 15 A 120 240 or 480 Vac ind and res 1 8 Hp 120 Vac Hp 240 Vac 0 5 A 125 Vdc 0 25 A 250 Vdc r...

Page 65: ...ents They comply with the NEMA 4X requirement for protection against corrosion in addition to NEMA enclosure standards met by other CX switches O ring seals make the enclosure weather proof but are outside of required flame paths maintaining explosion proof requirements HOUSING BASIC CONTACT ELECTRICAL SHAFT RESTORING REFERENCE SIZE SWITCHES RATING FORCE TO CENTRE Standard BZ 2 SPDT A With 81CX2 S...

Page 66: ...ns SPDT DPDT Single Pole Double Throw Double Pole Double Throw Snap action contacts 1NC 1NO Snap action contacts 2NC 2NO SPDT Double Break DPDT Double Break Applies only to listings with in NPT or in NPT Electrical ratings 10 amps continuous carry Circuits on any one pole must be the same polarity ac Volts Pilot duty 600 Vac 720 VA Amps at 0 35 Power Factor Vac Make Break A 120 60 6 SPDT 240 30 3 ...

Page 67: ...PT C BXR4S Centre neutral Operating torque max 0 45 N m 4 0 in lb Pretravel max PT 18 Overtravel min OT 57 Differential travel max DT 10 Operating temperature 1 C to 121 C 30 F to 250 F CONTACT CONDUIT ELECTRICAL RATING REFERENCE DPDT in 14NPT B LSXM4N DPDT 20 mm B LSX4M4N Maintained contact Operating torque max 0 45 N m 4 0 in lb Pretravel max PT 65 Overtravel min OT 20 Differential travel max DT...

Page 68: ...14NPT B LSXC4L BX CONTACT CONDUIT ELECTRICAL RATING REFERENCE SPDT 20 mm A BX4C3K DPDT in 14NPT B BXC4L DPDT 20 mm B BX4C4L Top pin plunger adjustable 21 6 0 85 7 9 0 31 Max operating point 72 0 2 83 Min operating point 65 7 2 59 Operating point 65 66 mm to 72 01 mm 2 585 in to 2 835 in CONTACT CONDUIT ELECTRICAL RATING REFERENCE SPDT in 14NPT A LSXV3K Top roller plunger Head can be set at 90 incr...

Page 69: ...slide actuation Operating point 44 1 mm 1 735 in LSX CONTACT CONDUIT ELECTRICAL RATING REFERENCE SPDT in 14NPT A LSXF3K BX CONTACT CONDUIT ELECTRICAL RATING REFERENCE SPDT in 14NPT A BXF3K Wobble actuated switches OPTIONS Plastic rod Operating force max OF 2 78 N 10 oz Pretravel max PT 25 4 mm 1 0 in Operating temperature 12 C to 93 C 10 F to 200 F CONTACT CONDUIT ELECTRICAL RATING REFERENCE SPDT ...

Page 70: ...68 www honeywell com sensing Blank page ...

Page 71: ...te Not all levers are compatible with all switches LEVERS ROLLER LIMIT SWITCH SERIES EXPLOSION PROOF SERIES REFERENCE MATERIAL GLA HDLS LS2 LS BX LSX CX EX 6PA57 Aluminium 6PA63 Stainless steel 6PA69 Spring rod 6PA80 Steel 6PA82 Steel 6PA102 Nylon 6PA144 Ball bearing GLZ51A Nylon GLZ51B Steel GLZ52A Nylon GLZ52B Steel GLZ54J Aluminium GLZ55B Steel LSZ51 N A LSZ51A Nylon LSZ51B Steel LSZ51C Nylon L...

Page 72: ...m Front 6PA138 EX One way roller lever RADIUS LENGTH REFERENCE Bronze roller clockwise 1 56 in 39 6 mm 6PA130 EX Bronze roller counter clockwise 1 56 in 39 6 mm 6PA142 EX Perpendicular cross roller lever RADIUS LENGTH REFERENCE Bronze roller 1 81 in 46 0 mm 6PA131 EX Yoke lever MOUNTED ON REFERENCE Nylon roller Front Back LSZ53A Metal roller Front Back LSZ53B Metal roller Front Front LSZ53D Nylon ...

Page 73: ...m Large rubber roller adjustable lever REFERENCE Ø 1 6 in X 0 50 in wide roller LSZ52W 40 6 mm X 12 7 mm Ø 2 in X 0 50 in wide roller LSZ52Y 50 8 mm X 12 7 mm Conveyor roller arm Operating radius length 6 78 in 172 2 mm REFERENCE Plastic roller 1 5 in Ø X 3 8 in long LSZ67AA 38 1 mm X 96 5 mm LEVERS Stainless steel levers Roller Diameter 0 75 in 19 1 mm Roller Width 0 25 in 6 35 mm OPTIONS Standar...

Page 74: ...Vac 5 amp SZR MY2 N1 AC220V 12 Vdc 125 Vdc 1 amp SZR MY2 N1 DC12V 24 Vdc 125 Vdc 1 amp SZR MY2 N1 DC24V Diode Protection COIL INPUT VOLTAGE MAX CONTACT RATING REFERENCE 24 Vdc 125 Vdc 1 amp SZR MY2 D1 DC24V LED Indicator Diode Protection COIL INPUT VOLTAGE MAX CONTACT RATING REFERENCE 24 Vdc 125 Vdc 1 amp SZR MY2 X1 DC24V SZR MY Series general purpose power relays are designed for a wide range of ...

Page 75: ...MY4 N1 AC110 120V 220 Vac 250 Vac 3 amp SZR MY4 N1 AC220V 12 Vdc 125 Vdc 0 6 amp SZR MY4 N1 DC12V 24 Vdc 125 Vdc 0 6 amp SZR MY4 N1 DC24V Diode Protection COIL INPUT VOLTAGE MAX CONTACT RATING REFERENCE 24 Vdc 125 Vdc 0 6 amp SZR MY4 D1 DC24V LED Indicator Diode Protection COIL INPUT VOLTAGE MAX CONTACT RATING REFERENCE 24 Vdc 125 Vdc 0 6 amp SZR MY4 X1 DC24V MY4 Series OPTIONS Standard PCB Termin...

Page 76: ...Standard PCB Terminal DPDT 0 5 0 02 2 0 0 08 1 0 0 04 4 5 0 18 Max 36 0 1 42 Max 21 5 0 85 Max 28 0 1 10 5 75 0 23 COIL INPUT VOLTAGE MAX CONTACT RATING REFERENCE 110 120 Vac 250 Vac 10 amp SZR LY2 1P AC110 120V 24 Vdc 125 Vdc 2 amp SZR LY2 1P DC24V Solder Plug In Terminal DPDT Max 36 0 1 42 0 5 0 02 5 0 0 20 3 0 0 12 6 4 0 26 Max 21 5 0 85 5 75 0 23 Max 28 0 1 10 14 O 3 0 0 12 Standard COIL INPUT...

Page 77: ...mp SZR LY4 N1 AC110 120V 220 Vac 250 Vac 10 amp SZR LY4 N1 AC220V 12 Vdc 125 Vdc 2 amp SZR LY4 N1 DC12V 24 Vdc 125 Vdc 2 amp SZR LY4 N1 DC24V Diode Protection COIL INPUT VOLTAGE MAX CONTACT RATING REFERENCE 24 Vdc 125 Vdc 2 amp SZR LY4 D1 DC24V LED Indicator Diode Protection COIL INPUT VOLTAGE MAX CONTACT RATING REFERENCE 24 Vdc 125 Vdc 2 amp SZR LY4 X1 DC24V LY4 Series OPTIONS Standard PCB Termin...

Page 78: ...6 0 61 35 2 1 39 62 0 0 1 2 44 004 2 O 4 5 0 18 Holes 2 M3 or 2 M4 25 0 0 99 18 0 0 70 Max 61 0 2 40 6 0 0 24 3 9 0 15 26 0 1 02 LY2 Series Socket TYPE POLES REFERENCE Rail socket 2 SZX SLF 08N LY4 Series Socket TYPE POLES REFERENCE Rail socket 4 SZX SLF 14 2 O 4 5 0 18 Holes 2 M4 25 0 0 2 0 99 008 19 0 0 75 2 5 0 10 14 5 0 57 25 0 0 99 4 2 0 17 30 0 1 18 26 0 1 02 47 0 1 85 67 0 2 64 22 0 0 87 8 ...

Page 79: ...ucts are designed to meet all applicable OSHA and ANSI standards Refer to pages 6 and 7 for more information about degrees of protection and electrical ratings Protective Guarding Protective guarding around a dangerous machine can be achieved with tamper resistant safety switches Safety switches incorporate positive opening operation such that even a welded contact will be mechanically broken and ...

Page 80: ...85 F Approvals CE UL CSA AC15 B300 DC13 Q300 Contacts Silver Low energy Gold plated Switching options Slow action contacts 1 Normally Closed 1 Normally Open Break Before Make 1NC 1NO BBM GKMF 1NC 1NO BBM low energy GKMA B C D 3 3 4 4 2 2 1 1 1 Brown 4 Black Blue 3 White 2 2 Normally Closed 2NC GKMF 2NC low energy GKMA B C D 3 3 4 4 2 2 1 1 1 Brown 4 Black Blue 3 White 2 Electrical ratings IEC 6094...

Page 81: ...KMB36 3 m 2NC low energy GKMB37 3 m 1NC 1NO BBM low energy GKMB39 Side exit M12 dc micro change connector CONTACT REFERENCE 1NC 1NO BBM GKMC03 2NC GKMC06 2NC low energy GKMC07 1NC 1NO BBM low energy GKMC09 Bottom exit M12 dc micro change connector CONTACT REFERENCE 1NC 1NO BBM GKMD03 2NC low energy GKMD07 1NC 1NO BBM low energy GKMD09 Dual exit M12 dc micro change connector CONTACT REFERENCE 1NC 1...

Page 82: ...ated contact version of the standard basic switch This improves reliability of switching at low currents and voltages by protecting the contact surfaces from contamination during operation or storage prior to use Standard silver contacts have a disadvantage in that the contact surface may tarnish under certain environmental conditions e g in the presence of moisture Low energy basic switches are r...

Page 83: ...n NPT GSDA06S1 1NC 1NO BBM PG 13 5 GSDB03S1 2NC PG 13 5 GSDB06S1 1NC 1NO 20 mm GSDC01S1 Rotated 90 either direction from center 12 5 0 49 24 8 0 97 2 0 08 11 5 0 45 5 1 0 20 45 1 77 70 2 76 28 90 min 90 min GSC Metal body CONTACT CONDUIT REFERENCE 1NC 1NO in NPT GSCA01S2 1NC 1NO BBM in NPT GSCA03S2 2NC in NPT GSCA06S2 2NC low energy PG 13 5 GSCB36S2 GSD Plastic body CONTACT CONDUIT REFERENCE 1NC 1...

Page 84: ...C to 85 C 13 F to 185 F Approvals IEC EN 60947 5 1 AC15 A300 DC13 Q300 UL CSA BG ACTUATED SWITCHES Rotated 90 to the left from center 70 2 76 45 1 77 104 4 09 CONTACT CONDUIT REFERENCE 2NC 2NO BBM in NPT GSEA44S1 3NC 1NO BBM in NPT GSEA46S1 4NC low energy 20 mm GSEC41S1 Rotated 90 either direction from center 12 5 0 49 24 8 0 97 2 0 08 11 5 0 45 5 1 0 20 45 1 77 70 2 76 28 90 min 90 min CONTACT CO...

Page 85: ...rsonnel are working on the machine When inserted the lockout device can accommodate up to four padlocks to prevent unauthorised removal of the device Mechanical life up to 15 million Sealing IP 67 NEMA UL type 1 4 12 13 Operating temperature 25 C to 85 C 13 F to 185 F Approvals CE CSA UL AC15 A300 A600 DC13 Q300 Contacts Silver Low energy Gold Switching options Snap action contacts 1NC 1NO Snap ac...

Page 86: ...orocarbon seal Single LED indicator CONDUIT CONTACT KEY REFERENCE 1 2 NPT 1NC 1NO Straight GKCA1L6 1 2 NPT 1NC 1NO 90 GKCA1L7 1 2 NPT 1NC 1NO None GKCA1LX 1 2 NPT 2NC None GKCA6LX 1 2 NPT 4NC Straight GKCA10L6 1 2 NPT 2NC 2NO BBM Straight GKCA14L6 1 2 NPT 2NC 2NO BBM 90 GKCA14L7 1 2 NPT 2NC 2NO BBM Side side GKCA14L9 1 2 NPT 4NC low energy None GKCA30LX 1 2 NPT 3NC 1NO BBM low energy None GKCA36LX...

Page 87: ...e GKR GKL Series The lockout device GKZL2 is specifically designed to prevent a key from being inserted either manually or by the access door being closed while maintenance personnel are working on the machine When inserted the lockout device can accommodate up to four padlocks to prevent unauthorised removal of the device Mechanical life up to 1 million Sealing IP 68 NEMA UL type 1 4 6P 12 13 Ope...

Page 88: ... 46 3NC BBM None A 24 Vdc GKLE46LXA2 Right 1 2 in NPT buna n seals CONTACT KEY LATCHING SOLENOID REFERENCE TYPE TYPE VOLTAGE 40 4NC None A 24 Vdc GKRE40LXA2 46 3NC BBM None A 24 Vdc GKRE46LXA2 IEC 60947 5 1 EN 60947 5 1 Designation Utilization Rated operational current le A VA Category at rated operational voltage Ue rating 120 V 240 V 380 V 480 V 500 V 600 V Make Break AC15 A600 6 3 1 9 1 5 1 4 1...

Page 89: ...y None S 24 Vdc GKRG36MXS2 36 3NC 1NO BBM low energy None S 120 Vac GKRG36MXS4 Opening to left and top 26 1 02 Left 1 2 in NPT buna n seals CONTACT KEY LATCHING SOLENOID REFERENCE TYPE TYPE VOLTAGE 3 1NC 1NO BBM None A 24 Vdc GKLE3PXA2 3 1NC 1NO BBM None A 120 Vac GKLE3PXA4 3 1NC 1NO BBM None S 24 Vdc GKLE3PXS2 3 1NC 1NO BBM None S 120 Vac GKLE3PXS4 36 3NC 1NO BBM low energy None A 24 Vdc GKLE36PX...

Page 90: ... 21 2 X ø 5 3 REFERENCE GKZ58 Spring loaded key left right 8 5 0 33 14 0 55 84 9 3 34 20 5 0 81 13 5 0 53 18 5 0 73 30 1 18 40 1 57 0 21 2 X ø 5 3 REFERENCE GKZ59 Locking slider bolt with actuating key 3x HOLE PROVIDED FOR LOCKOUT 19 0 75 41 81 76 1 646 030 14 0 55 7 0 7 28 03 37 10 1 52 1 460 060 26 77 1 52 1 054 060 115 87 4 562 140 0 7 5 51 03 4x ø 5 1 20 4 93 194 12 04 474 36 8 1 45 26 97 1 06...

Page 91: ... automated systems The 2CPS series is intended for use in very long cable runs of 152 m 500 ft or shorter such as long conveyor lines found in warehouses The CPS complies with Low Voltage Directive 73 23 EEC as amended by directive 93 68 EEC Machinery Directive 98 37 EEC only as the directives relate to the components being used in a safety function IEC EN 60947 1 IEC EN 60947 5 1 IEC EN 60947 5 5...

Page 92: ...117 42 4 623 50 8 2 1 172 72 6 8 152 4 6 0 81 28 3 2 6 35 0 25 99 06 3 9 1CPS Cable Pull Switch TENSIONED SLACK RUN RESET OFF 4X Ø 7 11 Ø 0 28 88 9 3 5 76 2 3 0 33 02 1 3 65 20 2 567 56 79 2 236 50 83 2 001 2X 26 67 1 050 3X 25 4 1 0 25 4 1 00 25 4 1 00 B C D A A Fully extended B Optional indicator C Conduit thread 3 total D Mounting pad 4 total 1CPS SAFETY SWITCHES 20 mm CONTACT INDICATOR REFEREN...

Page 93: ...44 6 9 63 TENSIONED SLACK TENSIONED SLACK A A B C C D D 6 4 0 25 40 5 1 60 A Fully extended B Optional indicator C Conduit thread 3 total D Mounting pad 4 total 2CPS No actuation right side cable maintained left side 1 2 in NPT CONTACT CONTACT BLOCK INDICATOR REFERENCE MOUNTING 2NC 2NO 1 None 2CPSA1A2 2NC 2NO 1 24 Vdc 2CPSA1A2A 2NC 2NO 1 120 Vac 2CPSA1A2B 3NC 1NO 1 None 2CPSA1B2 3NC 1NO 1 24 Vdc 2...

Page 94: ...92 www honeywell com sensing Blank page ...

Page 95: ...sensors magnetoresistive digital sensors and potentiometric rotary and linear sensors Sensors are directly compatible with other electronic circuits for application flexibility With the combined capabilities of three well known brand names Data Instruments Clarostat Electro and New England Instruments Honeywell the group continuously strives to remain at the forefront of position sensing technolog...

Page 96: ...18401 sold separately ELECTRICAL TRAVEL IN MM REFERENCE 6 0 152 4 LF2S06N5KB6A 9 0 228 6 LF2S09N5KB6A 12 0 304 8 LF2S12N5KB6A 14 0 355 6 LF2S14N5KB6A 18 0 457 2 LF2S18N5KB6A 24 0 609 6 LF2S24N5KB6A 30 0 762 0 LF2S30N5KB6A 36 0 914 4 LF2S36N5KB6A 48 0 1219 2 LF2S48N5KB6A Water resistant Mating connector E02903021 sold separately ELECTRICAL TRAVEL IN MM REFERENCE 6 0 152 4 LF2W06N5KB6A 9 0 228 6 LF2...

Page 97: ... 09 in OPTIONS Standard Binder Mating connector 3718401 sold separately ELECTRICAL TRAVEL MM IN REFERENCE 152 4 6 0 LF2S0152M5KB8A 228 6 9 0 LF2S0229M5KB8A 304 8 12 0 LF2S0305M5KB8A 355 6 14 0 LF2S0355M5KB8A 457 2 18 0 LF2S0457M5KB8A 609 6 24 0 LF2S0610M5KB8A 762 0 30 0 LF2S0762M5KB8A 914 4 36 0 LF2S0914M5KB8A 1219 2 48 0 LF2S1219M5KB8A Standard DIN 43650 Mating connector included ELECTRICAL TRAVE...

Page 98: ...5 mm 0 001 in Shaft M5x0 8 metric thread Termination Connector DIN 43560 Mechanical travel Electrical travel 5 0 mm 0 2 in Mating connector included ELECTRICAL TRAVEL TOTAL RESISTANCE HOUSING LENGTH REFERENCE MM IN OHM MM IN 101 6 4 0 2000 250 0 9 84 DR04N02KB7G 127 0 5 0 2000 280 0 11 02 DR05N02KB7G 152 4 6 0 5000 300 0 11 81 DR06N05KB7G 203 2 8 0 5000 352 0 13 86 DR08N05KB7G 228 6 9 0 5000 375 9...

Page 99: ...ge max 40 Vdc Starting force max Standard 0 45 kg 1 0 lb Water resistant 2 27 kg 5 0 lb Backlash max 0 025 mm 0 001 in Shaft Ø 1 4 in Termination Connector Binder Series 681 Housing length Electrical travel 3 05 in 77 5 mm Mechanical travel Electrical travel 0 2 in 5 1 mm Electrical Travel Total Resistance in mm Ohm SLF01 or SLW01 1 0 25 4 1500 SLF02 or SLW02 2 0 50 8 3000 SLF03 or SLW03 3 0 76 2 ...

Page 100: ...025R4 25 4 1 0 1500 SLF050R8 or SLW050R8 50 8 2 0 3000 SLF076R2 or SLW076R2 76 2 3 0 4500 SLF101R6 or SLW101R6 101 6 4 0 6000 SLF152R4 or SLW152R4 152 4 6 0 9000 OPTIONS Standard Mating connector 3718401 sold separately 0 1 Linearity ELECTRICAL TRAVEL REFERENCE 25 4 1 0 SLF025R4M1500B8A 50 8 2 0 SLF050R8M3000B8A 76 2 3 0 SLF076R2M4500B8A 101 6 4 0 SLF101R6M6000B8A 152 4 6 0 SLF152R4M9000B8A 1 0 Li...

Page 101: ...ended Black Ground Brown V out Connect to High Impedance Circuit 28 Jacketed cable 6 0 152 4 long min Housing length X Electrical Travel 1 50 38 1 OPTIONS Standard 0 1 Linearity ELECTRICAL TRAVEL REFERENCE 1 0 25 4 LTS01N01KB5C 2 0 50 8 LTS02N02KB5C 3 0 76 2 LTS03N03KB5C 4 0 101 6 LTS04N04KB5C 5 0 127 0 LTS05N05KB5C 6 0 152 4 LTS06N06KB5C 7 0 177 8 LTS07N07KB5C 8 0 203 2 LTS08N08KB5C 9 0 228 6 LTS...

Page 102: ...0 in 30 48 mm Mechanical travel Electrical travel 0 05 in 1 27 mm Electrical Travel Total Resistance in mm Ohm MLT0R5 0 5 12 7 750 MLT001 1 0 25 4 1500 MLT002 2 0 50 8 3000 MLT003 3 0 76 2 4500 MLT004 4 0 101 6 6000 MLT005 5 0 127 0 7500 MLT006 6 0 152 4 9000 Retracted 4 40 UNC 2A Thdx 50 12 7 long 3 4 19 05 1 8 3 18 3 8 9 53 Electrical Travel 1 2 30 48 Red V in Shaft Extended Black Ground Orange ...

Page 103: ... AVAILABLE FOR CLAMPING WITHOUT RESTRICTING ELECTRICAL TRAVEL Ø 0 516 13 11 Ø 0 156 3 96 Ø 0 813 20 65 BOLT CIRCLE 4 40 UNC THD 6 PLACES Dimensions in inches mm Ø 1 25 31 75 0 024 0 61 OFF CENTER 0 25 6 35 0 50 12 70 1 125 0 010 28 575 0 25 120 120 1 00 0 010 25 4 0 25 ELECTRICAL TRAVEL TOTAL RESISTANCE REFERENCE MM IN OHM 152 4 6 0 6000 AQLT06N06KFC 304 8 12 0 12000 AQLT12N12KFC 457 2 18 0 18000 ...

Page 104: ...at low cost Operating temperature 40 C to 85 C 40 F to 185 F Supply voltage max 30 Vdc Starting force max M22B 0 3 oz in torque M22S 1 0 oz in torque Total resistance 2000 Ohm Backlash max 0 1 Shaft Ø 3 175 mm 0 125 in Termination Gold plated solder terminals Housing size 22 0 mm 0 87 in Bearing type Sleeve Mechanical travel M22B 330 M22S Continuous rotation Electrical travel M22B 320 M22S 340 OPT...

Page 105: ...NCE MAX 350 0 8 oz in torque 0 075 WPM5KA4S4513 353 1 0 oz in torque 0 075 WPM5KA4S6520 B1 ELECTRICAL TRAVEL STARTING FORCE LINEARITY REFERENCE MAX 340 0 4 oz in torque 0 1 WPM5KB1S1809 345 0 4 oz in torque 0 1 WPM5KB1S2511 062 1 57 078 1 98 2 000 Dia 50 80 1 875 1 874 Dia 47 62 47 60 0 2497 0 2494 Dia shaft 6 342 6 334 0 093 2 36 0 333 8 46 0 500 0 032 12 70 0 81 0 800 20 32 M ADE I N U S A 1 2 3...

Page 106: ... to 0 1 366 2 0 003 to 0 03 366 3 Metric GRAM CENTIMETER REFERENCE 6 to 42 366 0M 1 to 7 5 366 2M 0 2 to 2 366 3M 651 Series Mid range 0 05 40 0 oz in The Series 651 Torque Watch provides accurate measurement of low static torque A 1 4 inch keyed chuck provides a simple means of coupling to the device under measurement OPTIONS Standard OUNCE INCHES REFERENCE 0 05 to 1 2 651C 1 1 to 20 651C 2 2 to ...

Page 107: ...OR REFERENCE Linear No 640ES103A06NAAY HRS100 Series Hall effect The HRS100 provides angular position information for a variety of sensing and control applications in the automotive marine truck off road industrial implementation aerospace and rail industries The use of magnetically coupled information in place of a mechanical wiper assembly provides a long life cost effective solution for harsh e...

Page 108: ... 0 25 OPTIONS 1 kOhm Resistance SHAFT RESISTANCE TAPER REFERENCE Slotted stainless steel Linear 578X1G48S102SA 5 kOhm Resistance SHAFT RESISTANCE TAPER REFERENCE Slotted stainless steel Linear 578X1G48S502SA 10 kOhm Resistance SHAFT RESISTANCE TAPER REFERENCE Slotted stainless steel Linear 578X1G48S103SA 574 Series Commercial potentiometer The 574 Series conductive plastic potentiometer offers low...

Page 109: ...1N56S102SP 5 kOhm Linear 590SX1N56S502SP 10 kOhm Linear 590SX1N56S103SP 100 kOhm Linear 590SX1N56S104SP 500 kOhm Linear 590SX1N56S504SP 1 MOhm Linear 590SX1N56S105SP 575 Series Commercial potentiometer The 575 Series conductive plastic potentiometer offers a smooth feel and robust construction with a thermoplastic housing bushing and shaft Terminals are solder hook style for panel mounting No hard...

Page 110: ...1000 1 5 kOhm 380C11500 2 kOhm 380C12000 2 5 kOhm 380C12500 5 kOhm 380C15000 10 kOhm 380C110K 15 kOhm 380C115K 20 kOhm 380C120K 25 kOhm 380C125K 50 kOhm 380C150K 100 kOhm 380C1100K 200 kOhm 380C1200K 250 kOhm 380C1250K 500 kOhm 380C1500K 1 MOhm 380C11MEG C2 0 625 in 15 88 mm screwdriver slotted shaft 0 5 in 12 7 mm L locking bushing C2 27 78 1 09 14 27 0 56 15 87 0 625 RESISTANCE REFERENCE 250 Ohm...

Page 111: ...h RESISTANCE TOLERANCE REFERENCE 100 Ohm 10 RV4NAYSD101A 250 Ohm 10 RV4NAYSD251A 500 Ohm 10 RV4NAYSD501A 1 kOhm 10 RV4NAYSD102A 2 5 kOhm 10 RV4NAYSD252A 5 kOhm 10 RV4NAYSD502A 10 kOhm 10 RV4NAYSD103A 25 kOhm 10 RV4NAYSD253A 50 kOhm 10 RV4NAYSD503A 100 kOhm 10 RV4NAYSD104A 250 kOhm 10 RV4NAYSD254A 500 kOhm 10 RV4NAYSD504A 750 Kohm 10 RV4NAYSD754A 1 MOhm 10 RV4NAYSD105A 5 MOhm 20 RV4NAYSD505B Lockin...

Page 112: ... 0 03 12 7 0 5 0 5 0 02 3 18 0 125 Dia 12 7 0 5 Dia Type Bushing Length Shaft Length RV6 6 35 0 25 22 23 0 875 Clarostat Rotary Potentiometers and Position Transducers continued OPTIONS Standard Bushing 6 35 mm 0 25 in L 0 875 in 22 23 mm shaft length RESISTANCE REFERENCE 100 Ohm RV6NAYSD101A 250 Ohm RV6NAYSD251A 500 Ohm RV6NAYSD501A 1 kOhm RV6NAYSD102A 2 5 kOhm RV6NAYSD252A 5 kOhm RV6NAYSD502A 10...

Page 113: ...kOhm 10 53C1500K 750 kOhm 10 53C1750K 1 MOhm 20 53C11MEG 2 5 MOhm 20 53C12 5MEG 5 MOhm 20 53C15MEG 585 Series Commercial potentiometer Our Series 585 offers a robust construction in a low cost commercial package using carbon composition elements and a metal shaft and bushing Power rating 0 05 W max 40 C Element type Carbon composition Terminal type 3 in line Bushing M 7 x 0 75 thread 7 mm L Shaft ...

Page 114: ... 2 bit 4 cycles 510E1A48F204PC 2 bit 6 cycles 510E1A48F206PC 2 bit 9 cycles 510E1A48F209PC 4 bit 16 cycles 510E1A48F416PC Horizontal Mount PC Terminals straight GREY CODE OPTIONS REFERENCE 2 bit 4 cycles 510E1A48F204PB 2 bit 6 cycles 510E1A48F206PB 2 bit 9 cycles 510E1A48F209PB 4 bit 16 cycles 510E1A48F416PB Brackets MOUNTING DIRECTION REFERENCE Vertical 510VBKT Horizontal 510HBKT 600 Series Optic...

Page 115: ...VCE 5 V 0 4 V max IF 20 mA and IC 0 25 mA 1 0 mA IF 35 mA and VCE 5V 0 4 V max IF 35 mA and IC 0 50 mA B 1 0 mA IF 20 mA and VCE 5 V 0 4 V max IF 20 mA and IC 0 50 mA 2 0 mA IF 35 mA and VCE 5V 0 4 V max IF 35 mA and IC 1 0 mA S 180 Series The S 180 Series consists of a gallum arsenide IRED and silicon phototransistor mounted in a rigid one piece polycarbonate housing All electrical options are av...

Page 116: ...o Tabs 0 25 mm 0 01 in S 862 N51 A No Tabs 1 27 mm 0 05 in S 860 N55 B No Tabs 1 27 mm 0 05 in S 861 N55 C No Tabs 1 27 mm 0 05 in S 862 N55 A 2 Tabs 0 25 mm 0 01 in S 860 T51 B 2 Tabs 0 25 mm 0 01 in S 861 T51 C 2 Tabs 0 25 mm 0 01 in S 862 T51 A 2 Tabs 1 27 mm 0 05 in S 860 T55 B 2 Tabs 1 27 mm 0 05 in S 861 T55 C 2 Tabs 1 27 mm 0 05 in S 862 T55 IR Opaque 5 59 mm 0 220 in Lead spacing IRED aper...

Page 117: ...olve application requirements Operating temperature 40 C to 80 C 40 F to 176 F IRED continuous forward current 50 mA IRED peak forward current 3 A IRED reverse voltage 3 V IRED power dissipation 100 mW Sensor collector emitter voltage 30 V Sensor emitter collector voltage 5 V Sensor power dissipation 100 mW OPTIONS IL VCE sat REFERENCE 500 uA min VCE 10 V IF 20 mA 0 4 V max IC 250 uA IF 20 mA S 80...

Page 118: ...116 www honeywell com sensing LINEAR AND ROTARY POSITION Blank page ...

Page 119: ...psed time of the acoustic pulse The diagram shows how the pulse travels from the transducer to the target is reflected at time T 2 and reaches the transducer at time T Below is a diagram of the voltage at the ultrasonic transducer Elapsed time T is directly proportional to object distance a a cT 2 where c is the velocity of sound Application criteria The maximum sensing range depends on a number o...

Page 120: ... two sensors opposite one another false echo signals can be received By using the inhibitor input maintaining minimum distances or restricting the beam angle with a focusing reflector the problem can be almost entirely avoided Synchronisation The majority of Honeywell ultrasonic distance sensors can be very easily synchronised by interconnecting the appropriate inputs or connecting them with an ex...

Page 121: ...atability 0 2 or 2 mm Response time 50 ms Supply voltage 18 to 30 V Sealing IP67 Housing M18 x 1 mm plastic PBTB Termination Preleaded 2 m REFERENCE 947 F4Y 2D 1C0 300E Max sensing distance 1500 mm Min sensing distance 200 mm Beam angle 8 Repeatability 0 2 or 2 mm Response time 100 ms Supply voltage 18 to 30 V Sealing IP67 Housing M18 x 1 mm plastic PBTB Termination Preleaded 2 m REFERENCE 947 F4Y...

Page 122: ...chemical resistant body and epoxy face Parameters are stored in non volatile memory OPTIONS 2 switching outputs PNP NO Analogue output 0 10 volts Beam angle 8 Repeatability 0 4 or 2 mm Supply voltage 19 to 30 V Sealing IP67 Housing M30 x 1 5 mm plastic PBTB M30 x 1 5 3 5 11 2 Max sensing distance 3500 mm Min sensing distance 350 mm Switching frequency 0 8 Hz REFERENCE 944 T4V 2D 1C1 130E Max sensi...

Page 123: ...rogrammable 30 mm diameter sensor Voltage output 0 10 V 2 switching outputs PNP Max sensing distance 1500 mm Min sensing distance 150 mm Beam angle 10 Repeatability 0 4 or 2 mm Switching frequency 5 to 30 Hz Response time 100 ms Supply voltage 19 to 30 V Sealing IP65 Housing M30 x 1 5 mm stainless steel REFERENCE 942 A4N 2D 1C1 220S Max sensing distance 3000 mm Min sensing distance 300 mm Beam ang...

Page 124: ...s Supply voltage 19 to 30 V Sealing IP65 Housing M30 stainless steel REFERENCE Complete sensor 942 M3A 2D 1G1 220S 941 Series Limit switch style Max sensing distance 1500 mm Min sensing distance adjustable 200 mm Beam angle 10 Repeatability 1 mm Supply voltage 18 to 50 V Sealing IP65 Housing Zinc die cast sea water resistant paint finish OPTIONS Analogue voltage output 0 10 V Response time 150 ms ...

Page 125: ...Max sensing distance 4000 mm Min sensing distance 500 mm Response time 300 ms REFERENCE 946 A4V 2D 2C0 85E Max sensing distance 6000 mm Min sensing distance 800 mm Response time 500 ms REFERENCE 946 A4V 2D 2C0 65E 2 adjustable switching outputs PNP NO Beam angle 5 Repeatability 1 Supply voltage 10 to 30 V Sealing IP65 Housing M30 x 1 5 mm stainless steel Termination M12 connector Max sensing dista...

Page 126: ...pe DIN rail mount 2 holes Ø4 5 mm 75 0 2 95 50 0 1 97 35 0 1 38 37 5 1 48 60 0 2 36 62 5 2 46 4 8 0 19 110 0 4 33 6 0 0 24 REFERENCE FF MADB24RB Beam Deflectors Beam deflectors deflect the ultrasonic beam by 90 with virtually no signal loss They are extremely useful in applications where space is limited they allow the space required for the dead zone to be accommodated when setting up the sensor ...

Page 127: ... female metal cable connector with 2 metres of cable attached It is used with the 946 series but may be used for any industrial sensor with standard M12 4 pin or 5 pin connector The 55002 cable connector is included with every sensor of the 946 series Use with Series 940 941 944 946 947 Termination Female M12 Number of pins 5 REFERENCE 55002 Female 8 pin 2 metre cable 942 Series Compact The 551951...

Page 128: ...ed software is easy to use and is supplied on a floppy disc with the programming cable REFERENCE 942 A Series Separate 55195101 101 942 N Series Compact 55195101 102 942 T Series 55000018 001 includes programming cable Programming adaptor for 946 Series Use with Series 946 Sealing IP65 Number of pins 4 REFERENCE 40779 942 Series Compact programming module The 55000005 002 is a programming module f...

Page 129: ...teel media isolation which eliminates the need for internal seals Our stainless steel pressure transducers utilize bonded semiconductor strain gauge technology and are designed for demanding environments involving corrosive media They are manufactured in a variety of packages that are widely used in medical equipment compressors hydraulic controls transportation agriculture and refrigeration appli...

Page 130: ... 2 000 psis ABH02KPSC1B Sealed Gauge 0 psis to 3 000 psis ABH03KPSC1B Bendix High Temperature Connector 54 C to 149 C 65 F to 300 F MEASUREMENT TYPE PRESSURE RANGE REFERENCE Absolute 0 psia to 25 psia ABH025PABB Sealed Gauge 0 psis to 3 000 psis ABH03KPSBB Sealed Gauge 0 psis to 10 000 psis ABH10KPSBB BL Series The BL pressure transmitter has a conventional 4 mA to 20 mA output and is available wi...

Page 131: ...ggers and instrumentation used in processing environments Its 4 mA to 20 mA output is ideal for remote monitoring of both primary and secondary process variables The DATAMATE is made of series 300 stainless steel It is suitable for use with a variety of media that would otherwise require insulators It is also intrinsically safe when used within approved barriers for use in Class I Division I Group...

Page 132: ... 0 psig to 500 psig EA500PG1QD Gauge 0 psig to 1 000 psig EA01KPG1QD Gauge 0 psig to 5 000 psig EA05KPG1QD Output 1 kHz to 6 kHz 40 C to 85 C 40 F to 185 F MEASUREMENT TYPE PRESSURE RANGE REFERENCE Gauge 0 psig to 300 psig EA300PG1QF Gauge 0 psig to 500 psig EA500PG1QF Eclipse Series The Eclipse EC Series pressure transducers are designed for OEMS who require a reliable pressure transducer for ind...

Page 133: ...NPT Connector MEASUREMENT TYPE PRESSURE RANGE REFERENCE Sealed Gauge 0 psis to 200 psis EC200PS1PC Sealed Gauge 0 psis to 300 psis EC300PS1PC Sealed Gauge 0 psis to 500 psis EC500PS1PC Sealed Gauge 0 psis to 2 000 psis EC02KPS1PC Sealed Gauge 0 psis to 3 000 psis EC03KPS1PC G1 4 in 19 BSP Connector MEASUREMENT TYPE PRESSURE RANGE REFERENCE Sealed Gauge 0 bar to 350 bar EC350BS6PC 4 mA to 20 mA Out...

Page 134: ...ge 0 psig to 15 psig MM015PG1QA Gauge 0 psig to 100 psig MM100PG1QA Gauge 0 psig to 200 psig MM200PG1QA Gauge 0 psig to 500 psig MM500PG1QA Gauge 0 psig to 1 000 psig MM01KPG1QA Gauge 0 psig to 5 000 psig MM05KPG1QA Hollingsworth 3 8 in UNF Connector MEASUREMENT TYPE PRESSURE RANGE REFERENCE Gauge 0 psig to 5 000 psig MM05KPG3QA PIN CODES ARE FOR OPTIONAL HIRSCHMANN AND HOLLINGSWORTH CONNECTORS ME...

Page 135: ...25PA1C1DE Absolute 0 psia to 50 psia SA050PA1C1DE SR Series The Model SR is intended for OEMs requiring a small pressure sensor with high pressure capability and superior corrosion resistance Constructed of brazen assembly of 300 series stainless steels the SR can tolerate a wide variety of corrosive medial without risk of leaking The SR s design provide high working pressures and high overload an...

Page 136: ...8 NPT Connector SUPPLY VOLTAGE PRESSURE RANGE REFERENCE 9 5 Vdc to 35 0 Vdc 0 psis to 100 psis ML100PS2PG 9 5 Vdc to 35 0 Vdc 0 psis to 300 psis ML300PS2PG 9 5 Vdc to 35 0 Vdc 0 bar to 60 bar ML060BS2PG ST Series The Model ST pressure transducer combines Honeywell s proven silicon pressure sensing with the latest in ASIC technology in a rugged industrial package High value coupled with outstanding...

Page 137: ...acuum Gauge Series Flush Mount with Flange MEASUREMENT PRESSURE RANGE REFERENCE Vacuum Gauge 0 psig to 15 psig 19C015PV3K 1 4 in 18 NPT MEASUREMENT PRESSURE RANGE REFERENCE Vacuum Gauge 0 psig to 100 psig 19C100PV5L Vacuum Gauge 0 psig to 15 psig 19C015PV5L 50 0 2 0 NOMEX INSULATED RIBBON CABLE W 2 54 0 10 PIN SPACING 24 AWG EQUIV 9 27 0 365 7 37 0 290 5 59 0 220 3 18 0 125 000 4X 3 2 0 125 GROOVE...

Page 138: ... calibration This design has proven to be highly reliable stable and accurate Supply voltage 1 5 mA or 10 Vdc Signal conditioning Unamplified Operating temperature range 40 C to 125 C 40 F to 257 F Compensated temperature range 0 C to 82 C 32 F to 179 F OPTIONS Compensated Series Ring with Back Support 50 0 mm 2 0 in Nomex ribbon c a b l e OUT A OUT IDENTIFIER 50 0 2 0 NOMEX INSULATED STRIP CABLE ...

Page 139: ...ABLE 24 AWG CONDUCTORS SHIELDED IN PAIRS WITH DRAIN WIRE CUSTOMER SPECIFIED LENGTH IN FEET VENT TUBE GAUGE UNITS ONLY 71 7 2 82 17 77 0 70 11 42 0 45 10 0 0 39 000 1 8 27 NPT TIG WELD LOCATION TIG WELD LOCATION Ø 10 29 0 405 22 2 0 875 HEX Ø 4 34 Ø0 171 19 0 0 70 Ø 20 7 0 815 SUPPLY VOLTAGE PRESSURE RANGE REFERENCE 10 0 Vdc 0 psi to 100 psi SPTMV0100PG4W02 1 8 in 27 NPT 0 609 m 2 ft 4 Conductor sh...

Page 140: ...4 1 0 96 typ Tube stub ends 24 1 11 0 1 2 tube stub 77 0 max 47 0 12 0 0 50 1 86 05 typ 0 96 0 44 3 20 typ 4 0 mA to 20 0 mA Output 1 2 in Male Face Seal Connector 1 83 m 6 ft 2 Conductor Cable MEASUREMENT TYPE PRESSURE RANGE REFERENCE Compound 14 7 psig to 250 psig F14WMV250CP 1 4 in Male Face Seal Bendix Male Connector MEASUREMENT TYPE PRESSURE RANGE REFERENCE Compound 14 7 psig to 100 psig F14V...

Page 141: ...le MEASUREMENT TYPE PRESSURE RANGE REFERENCE Compound 14 7 psig to 100 psig S14VSV210BCP Compound 14 7 psig to 100 psig S14VSV70BCP S1 Series All S1 pressure transducers are manufactured in our Class 10 clean room environment Our single port pressure transducers are specifically designed for the semiconductor industry Their long life coupled with long term stability can greatly reduce or eliminate...

Page 142: ... ft 38 1 1 50 82 5 3 25 z s 38 1 1 50 38 1 1 50 z s 38 1 1 50 38 1 1 50 72 4 2 85 38 1 1 50 CABLE 2 COND 1 8 m 6 ft z s 38 1 1 50 82 5 3 25 26 1 1 03 35 9 1 42 77 0 3 03 42 7 1 68 CABLE 2 COND 1 8 m 6 ft BF Transducer at bottom front display orientation BS Transducer at bottom side display orientation CV Transducer at center back vertical display orientation CH Transducer at center back horizontal...

Page 143: ...42 26 1 1 03 Single port display orientation and transducer location BN Transducer at bottom CN Transducer at center back 32 9 1 29 32 3 1 27 10 9 0 43 6 4 0 25 4 57 0 18 32 3 1 27 VM 1 4 in male face seal VS 1 4 in male face seal swivel VF 1 4 in female face seal T4 1 4 in tube seal Single port connection options Flow through connection options T4 1 4 in tube stub VF 1 4 in female face seal VM 1 ...

Page 144: ...125PG5DC SS Housing 1 8 in NPT MEASUREMENT TYPE PRESSURE RANGE REFERENCE Gauge 0 psig to 500 psig BE 4R500PG4DS SS Housing 7 16 in 20 UNF MEASUREMENT TYPE PRESSURE RANGE REFERENCE Gauge 0 psig to 5 000 psig BE 4R5000PG6DS CRS Housing 7 16 in 20 UNF MEASUREMENT TYPE PRESSURE RANGE REFERENCE Gauge 0 psig to 5 000 psig BE 4R5000PG6DC COMMON V out V 0 95 0 04 0 60 0 02 1 37 0 05 1 4 18NPT PLATED CRS H...

Page 145: ... marine applications Fibre Optic Sensors Active optoelectronic components and sub assemblies LEDs transmitters fiber DIPs receivers and modules for the datacom market Force Sensors Precise reliable performance in compact commercial grade packaging Hour Meters Honeywell s Hobbs brand products are designed for elapsed time measurement for testing leasing maintenance and warranty programs The meter f...

Page 146: ...ing We achieve accuracies of 0 05 in pressure sensing and our calibration load cells have accuracies of 0 002 Our unique expertise is in the packaging of our sensor technology but we can provide you with reliable engineered solutions whether they are standard off the shelf transducers developed for general applications or sensors developed to meet unique requirements The Sensotec range of transduc...

Page 147: ...well SA Phone 33 1 60 19 80 40 FAX 33 1 60 19 81 73 Germany Honeywell AG Phone 49 69 8064 444 FAX 49 69 8064 442 Hungary Honeywell Kft Phone 361 451 43 00 FAX 361 451 43 43 Italy Honeywell S p A Phone 39 02 92146 450 456 FAX 39 02 92146 490 The Netherlands Honeywell B V Phone 31 20 565 69 11 FAX 31 20 565 66 00 Norway Honeywell A S Phone 47 66 76 20 00 FAX 47 66 76 20 90 Poland Honeywell Sp zo o P...

Page 148: ...ations may change at any time without notice The information we supply is believed to be accurate and reliable as of this printing However we assume no responsibility for its use This publication does not constitute a contract between Honeywell and its customers The contents may be changed at any time without notice It is the customer s responsibility to ensure safe installation and operation of t...

Reviews: