ST699 ELECTRONIC DUAL ZONE TIMER

Honeywell Control Systems Limited

Helping You Control Your World

Newhouse Industrial Estate
Motherwell ML1 5SB
United Kingdom

EN0R 8439 R0

NOTE: In the Sundial S, W, and Y Plan wiring diagrams,

connections are shown to basic boilers only.  For
wiring connections to pump overrun boilers refer to
boiler manufacturers instructions or Honeywell for
assistance.

Final Assembly

When the wiring is completed, replace the terminal cover
ensuring it is correctly installed with ends located under the
tabs and the locking pin through the locating hole.

Replace the timer onto the wallplate, ensuring it is firmly
secured by the three securing clips.

Switch on the power and refer to the user's guide for
programming details.

If the display remains blank, press the RESET button
with a blunt object. (e.g. a pencil)

C-Plan

ROOM STAT.

CYLINDER

STAT.

MID-POSITION VALVE

BOILER

PUMP

CLOCK

3 A max

ST699

Y-Plan

ST699

W-Plan

T6360/T4360

ROOM STAT.

L641

CYLINDER

STAT.

V4044

DIVERTING VALVE

BOILER

PUMP

CLOCK

3 A max

ST699

ST699

T6360/T4360

ROOM STAT.

L641

CYLINDER

STAT.

V4043H

2 PORT ZONE VALVE

BOILER

PUMP

CLOCK

3 A max

SUNDIAL PLAN WIRING DIAGRAMS

S-Plan

HEATING

HOT
WATER

BOILER

PUMP

CLOCK

ST699

V4043H

2 PORT ZONE VALVE

V4043H

2 PORT ZONE VALVE

ROOM STAT.

CYLINDER

STAT.

Summary of Contents for ST699

Page 1: ...one timer on the market ST699 is designed for European CEN approval FEATURES 24 hour programme Independent heating and hot water channels One or Two ON OFF periods per day Built in programme Temporary programme override advance 7 day battery back up Compact size AM PM or 24 hour clock format factory option Wallplate compatibility with 7 day version ST799 10 minute programme resolution 3 A resistiv...

Page 2: ...ackup following a 24 hour charging period Switch rating 2 x SPDT potential free 3 A resistive 230 V 10 50 Hz 3 A inductive 0 6 pf Programme 24 hour with two ON OFF periods daily Programme resolution 10 minutes Programme day 03 00 AM to 02 50 AM on the next day Override Advance next programme time change Wiring Surface or single wallbox UA1 size Wiring access Rear or bottom edge surface wiring acce...

Page 3: ...A maximum of two 2 5 mm2 cross sectional area wires can be connected to each terminal as shown in fig 3 Each wire should be stripped of insulation to a length no greater than 7mm to safeguard against the possibility of electrical shorts Fig 2 A link must be provided between L 5 8 on the subbase of ST699 for all Sundial Plans or fully controlled pumped primary systems Fig 3 Basic System 3 as System...

Page 4: ...s firmly secured by the three securing clips Switch on the power and refer to the user s guide for programming details If the display remains blank press the RESET button with a blunt object e g a pencil C Plan ROOM STAT CYLINDER STAT MID POSITION VALVE BOILER PUMP CLOCK 3 A max ST699 Y Plan ST699 W Plan T6360 T4360 ROOM STAT L641 CYLINDER STAT V4044 DIVERTING VALVE BOILER PUMP CLOCK 3 A max ST699...

Page 5: ...ut our full range of Heating Products Central Heating Controls Honeywell Heating Controls Danfoss Heating Controls Radiator Valves Fernox Sentinel Magnaclean Warmup underfloor heating Water Heaters Hand Dryers ...