56
SPM Flex Gas Detector
Figure 34.
manifold
supply and
exhaust
tubing
wire guides (2)
pump
bracket
screws (3)
pump bracket
pump and manifold
Pump assembly (detail, shown without wires for clarity)
9.
Separate the pump manifold from the pump. Disconnect the two push fittings by
gently twisting the jeweler’s screwdriver as shown in Figure 35.
Figure 35.
push fittings
area of detail
pump
manifold
Disconnecting the push fittings
10.
Disconnect the pump wiring connector from the PCB. Six connectors are supplied
by that wire bundle. The pump’s connector is the small black one with the red and
grey wires.
Summary of Contents for SPM Flex
Page 1: ...SPM Flex Single Point Monitor Gas Detector User Manual ...
Page 2: ......
Page 27: ...27 SPM Flex Gas Detector Setup Installation drawing Figure 18 Installation drawing ...
Page 70: ...70 SPM Flex Gas Detector ...
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ...SPM Flex Gas Detector User Manual 1998M0845 Revision 07 October 2016 2016 Honeywell Analytics ...
Page 77: ......