![Honeywell SmartLine RMA801 User Manual Download Page 55](http://html.mh-extra.com/html/honeywell/smartline-rma801/smartline-rma801_user-manual_151889055.webp)
Revision 2
RMA803 Remote Indicator User's Guide
44
Marking ATEX Directive
a. General
The following information is provided as part of the labeling of the Remote Indicator:
Name and Address of the manufacturer
The serial number of the Remote Indicator is located on the Meter Body data-plate. The
first two digits of the serial number identify the year (02) and the second two digits identify
the week of the year (23); for example, 0223xxxxxxxx indicates that the product was
manufactured in 2002, in the 23rd week.
b. Apparatus Marked with Multiple Types of Protection
The user must determine the type of protection required for installation the equipment.
The user shall then check the box [ ] adjacent to the type of protection used on the
equipment certification nameplate. Once a type of protection has been checked on the
nameplate, the equipment shall not then be reinstalled using any of the other certification
types.
c. WARNINGS and Cautions
Non-Incendive / Non-Sparking (Division 2 and Zone 2 Environments):
WARNING
– EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY
IMPAIR SUITABILITY FOR CLASS I, DIVISION 2
Intrinsically Safe (Divisions 1, Zone 1 and Zone 2 Environments):
WARNING
– EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY
IMPAIR INTRINSIC SAFETY.
WARNING
– DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS
PRESENT.
Explosion-Proof (Division 1 and Zone 1 Environments):
WARNING
– DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS
PRESENT.
WARNING
– DO NOT OPEN WHEN ENERGIZED
“OPEN CIRCUIT BEFORE REMOVING COVER”
Flameproof (Division 1 and Zone 1 Environments):
WARNING
– DO NOT OPEN WHEN ENERGIZED
General Requirements / Increased Safety (Zone 1):
WARNING
– DO NOT OPEN WHEN ENERGIZED
WARNING
– OPEN CIRCUIT BEFORE REMOVING COVER
All Protective Measures:
WARNING:
FOR CONNECTION IN AMBIENTS ABOVE 60oC USE WIRE
RATED 105oC
Summary of Contents for SmartLine RMA801
Page 2: ......
Page 11: ......
Page 50: ...39 RMA803 Remote Indicator User s Guide Revision 2 ...
Page 51: ...Revision 2 RMA803 Remote Indicator User s Guide 40 ...
Page 52: ...41 RMA803 Remote Indicator User s Guide Revision 2 ...
Page 57: ...Revision 2 RMA803 Remote Indicator User s Guide 46 Control Drawing 50089981 ...
Page 58: ...47 RMA803 Remote Indicator User s Guide Revision 2 ...
Page 59: ...Revision 2 RMA803 Remote Indicator User s Guide 48 ...