Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2
7
4.1 Transmitter
The transmitter enclosure has three threaded entries. The two cable/conduit entries either
side of the upper part of the transmitter housing are for connecting the power source,
signal output and relay contacts to associated signalling equipment. The bottom entry
allows direct connection of the sensor socket. There is a mounting plate incorporated into
the transmitter housing allowing for various mounting configuration options.
A local LCD provides gas type, concentration, alarm and operating status. The display
provides numerical, bar graph and icon information.
Diagnostic information may also be displayed when the transmitter is interrogated using
a magnet. The transmitter cover has a glass window which allows use of the Magnetic
Wand to activate the three user interface magnetic switches that are located on the front
of the display module. The magnet also enables a non intrusive, one-man calibration and
configuration facility for the Sensepoint XCD.
4.2 Flammable, Toxic Oxygen Gas sensors
The Sensepoint XCD transmitter is designed to work with a variety of gas sensors for
detecting flammable gases. Sensepoint XCD sensors use NDIR infrared and electro-
catalytic technologies.
In addition, the Sensepoint XCD transmitter is designed to work with a wide range of
toxic gas sensors. Sensepoint XCD sensors for monitoring toxic gas oxygen use electro-
chemical cell (ECC) technology.
Diagram 2: Sensepoint XCD Display and Magnetic Switches
Measuring
Units
Inhibit Icon
Test Pass Icon
Warning/
Fault Icon
Magnetic Wand
activation Icon
Gas Type
Magnetic
MENU/ENTER
Switch
Magnetic
UP Switch
Magnetic
DOWN
Switch
Gas Reading
Bar Graph
Alarm Icon
Full Scale
Calibration Icon
Summary of Contents for Sensepoint XCD
Page 1: ...Technical Manual Sensepoint XCD Gas Detector P R E L A U N C H ...
Page 54: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 54 17 6 Mounting Bracket Drawing ...
Page 56: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 56 China GB Ex English Version ...
Page 57: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 57 China PA Certification ...
Page 58: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 58 18 2 Korea KTL ...
Page 60: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 60 ATEX for Sensor ...
Page 62: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 62 IEC Ex for Sensor ...