background image

 

D

ESIGN 

S

PECIFICATIONS 

 

 

Specifications for the Supplemental Window

 

 

 
In applications where a secondary window is installed with the IS4125, the 
following recommendations should be followed in order to achieve the best 
performance.   While these recommendations provide general guidelines for a 
successful integration and installation, it will take some testing to find exact 
parameters to optimize scan performance and auto detection in each application. 
 

 

The window should be tempered or chemically strengthened glass. 

 

The window should be of optical quality and have a transmission of 98% 
or greater between 600 nm – 700 nm. 

 

The window should be optically flat, clear, and free of inclusions, 
scratches and pits. 

 

The window should not have birefringence.   

 

The window should have an anti-reflective coating on both sides to 
minimize "ghost" images or reflections. 

 

The window should not be thicker than 2.0 mm.   

 

The window and the engine should be mounted in a way to avoid direct 
reflections of both the laser beam and LED of the object detection from 
hitting the scan engine.   

 

The angle between the window and the engine should be approximately 
15° to 20°, but should be adjusted as needed.  See Figure 6.  

 

 

Figure 6. Supplemental Window Angle 

 

In rare instances where a supplemental window was previously installed and the 
factory default long range is enabled, the new object detection mechanism may 
behave differently.  If this occurs, scan the 

Enable

 

Short Range Object Detectio

bar code below to configure the engine to short range object detection. 
 

Enable Short Range Object Detection 

³

1

1

8

7

1

1

 

 

 

11

Summary of Contents for ScanQuest IS4100 Series

Page 1: ...IS4100 ScanQuest Series Laser Scan Engine Installation and User s Guide ...

Page 2: ...ntial damages resulting from the furnishing performance or use of this manual This document contains propriety information that is protected by copyright All rights reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII 1998 2010 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Tr...

Page 3: ...l 7 Electrical 7 Environmental 8 Compliance 8 IS4125 Depth of Field 9 IS4125 Object Detection 10 Design Specifications Specifications for the Supplemental Window 11 Default Settings IS4125 Communication Parameters 12 Scanner Terminations IS4125 47 Connector Pin Assignments 18 IS4125 38 Connector Pin Assignments 19 IS4125 41 IS4125 63 IS4125 76 Connector Pin Assignments 20 IS4125 163 Connector Pin ...

Page 4: ...0 Timing Diagram 23 Regulatory Requirements and Warnings Regulatory Requirements 24 Europe 25 United States 26 Canada 27 Warnings 27 Limited Warranty 28 Patents 29 Index 30 Customer Support 32 Technical Assistance 32 Product Service and Repair 33 ...

Page 5: ...s Honeywell will assist its customers in complying with the necessary procedures Theory of Operation An object detection device is located behind the scanner window initiates the scanning process The detection device is active as long as the unit is being powered When the laser decodes a bar code the scan engine transmits the data to the host system If the same bar code stays in the field after su...

Page 6: ...UFACTURE PART NO 19 07092 Flex Ribbon 12 Pos x 70mm Burndy BFC12X70A4 M 07102 Thru Hole 12 Pos ZIF Connector Burndy FLWSLW125 1C7 M 07103 Flex Ribbon 12 Pos x 130mm Burndy BFC12X30A4 IS4110 Non Decoded Scan Engine Part Numbers PN DESCRIPTION MANUFACTURE PART NO M 07104 Flex Ribbon 10 POS x 130mm Burndy BFC10X130A4 ...

Page 7: ...Object Detection Device When a specified time has elapsed without any scanning the unit will enter a standby mode To reactivate the unit present an object in front of the window Ribbon Cables This IS4110 has a 10 position FFC FPC cable and the IS4125 has a 12 position FFC FPC cable Refer to Scanner Termination starting on page 18 3 ...

Page 8: ... The following are examples of these labels Figure 3 Labels Maintenance Smudges and dirt on the unit s window can interfere with the unit s performance If the window requires cleaning use only a mild glass cleaner containing no ammonia When cleaning the window spray the cleaner onto a lint free non abrasive cleaning cloth then gently wipe the window clean 4 ...

Page 9: ...l turn off In this stage the scan engine s computer is on standby To reactivate the unit present an object within the scan field APPLICATIONS AND PROTOCOLS The model number on each scan engine includes the scan engine number and communications protocol Unit Communication Protocol s Type IS4110 Laser Data Non decode IS4125 41 IS4125 76 RS232 and Light Pen Emulation Flash Upgradeable Firmware IS4125...

Page 10: ...nes per second minimum Scan Pattern Single scan line Standard 0 173 mm 6 8 mil Resolution High Density 0 132 mm 5 2 mil Roll Pitch Skew 30 56 58 at 100 mm distance Sweep Angle 60 Scan Width 40 mm 1 57 Face 280 mm 11 00 200 mm 8 00 Print Contrast 35 minimum reflectance difference Decode Capability All standard 1D symbologies including GS1 DataBar IS4125 System Interfaces RS232C Light Pen Emulation ...

Page 11: ...10 Termination Low profile ZIF 10 pin connector that accepts a 1 mm x 12 position FFC FPC cable ELECTRICAL Power 0 6 watts Input Voltage 5VDC 0 25V Operating Current 120 mA typical 5VDC Sleep Current 22 mA 5VDC typical for RS232 C TTL RS232 and Keyboard Wedge Suspend Current 1 mA 5VDC typical for USB IS4125 Idle Current 58 mA typical 5VDC Power 0 375 watts Input Voltage 5VDC 0 25V Operating Curren...

Page 12: ...Humidity 5 to 95 relative humidity non condensing Vibration 7G over 10 500 Hz IS4125 Light Levels Up to 60 000 Lux 5 574 footcandles COMPLIANCE Laser Class Class 2 IEC 60825 1 EN 60825 1 IS4110 EMC FCC Part 15 ICES 003 EN 5022 Class A IS4125 EMC FCC Part 15 ICES 003 EN 5022 Class B Specifications are subject to change without notice ...

Page 13: ...inimum Bar Code Element Width Standard High Density A B C D E F G H I J mm 17 19 25 33 53 13 16 18 25 33 mil 6 8 7 5 10 4 13 21 5 2 6 1 7 2 10 4 13 Figure 4 Depth of Field Specifications are subject to change without notice 9 ...

Page 14: ... of the engine To mitigate the problem please try one of the following suggestions 1 Avoid mounting the engine directly facing the ambient light source 2 Avoid mounting the engine facing a light colored or reflective surface 3 Avoid mounting the engine towards a surface at a distance close to the long range 9 11 of object detection 4 Configure the object detection range to short 4 7 10 ...

Page 15: ...ches and pits The window should not have birefringence The window should have an anti reflective coating on both sides to minimize ghost images or reflections The window should not be thicker than 2 0 mm The window and the engine should be mounted in a way to avoid direct reflections of both the laser beam and LED of the object detection from hitting the scan engine The angle between the window an...

Page 16: ...er a check mark will appear in interface column Parameter Default RS232 OR RS232 TTL Light Pen Keyboard Wedge USB Enter Configuration Mode After Any Scan Enter Configuration Mode Only on First Scan Short Range Activation Long Range Activation Normal Scan Custom Scan DTR Activation DC2 Activation Address Based Activation NOREAD message Transmission Turn on Green LED during NOREAD Transmit Same Symb...

Page 17: ...its RTS CTS Character RTS CTS Message RTS CTS ACK NAK XON XOFF No Intercharacter Delay 1 Millisecond Intercharacter Delay 5 Millisecond Intercharacter Delay 10 Millisecond Intercharacter Delay 25 Millisecond Intercharacter Delay 100 Millisecond Intercharacter Delay DTR Input DTR Scan Disable DE Disable Command LRC Calc Transmit RS232 Start LRC on first RS232 Byte Start LRC on Second RS232 Byte Car...

Page 18: ...Pen UPC EAN Full ASCII code 39 Code 39 Codabar Code 128 Code 93 Code 11 GS1 DataBar Enable GS1 DataBar ID e0 GS1 DataBar App ID 01 GS1 DataBar Check Digit GS1 DataBar Expanded Enable Expanded ID e0 GS1 DataBar Limited Enable GS1 DataBar Limited ID e0 GS1 DataBar Limited App ID 01 GS1 DataBar Limited Check Digit Interleaved 2 of 5 Hong Kong Matrix 2 of 5 Airline 2 of 5 Minimum 1 Character Code Leng...

Page 19: ...mit Convert EAN 8 to EAN 13 Prefix ID for UPC EAN 2 Digit Supplements Scan 5 Digit Supplements Scan Bookland Scan Supplement Required Bookland to ISNB Transmit ISBN CD Mod 43 Check digit Code 39 Transmit Mod 43 Check Digit Code 39 Transmit Start Stop Code 39 CLSI Editing Enable ITF Check Digit Transmit Mod 10 ITF Check Digit 2 of 5 Symbol Lengths Variable ISBN Reformatting Coupon Code 128 C1 Trans...

Page 20: ... Check Digit UK Plessy UK Plessey Check Digit UK Plessey Special Format A to X conversion UK Scan Count Test Mode Scanability Test Mode Normal Scan Operating Test Mode Default to ScanPal Communication parameters Code ID Code ID Sanyo 635 ECR Protocol Post Software ID characters Newcode Mode A Newcode Mode B SNI Beetle Mode BIO DATA Mode Enable Sineko Mode Enable Caps Lock Mode for MI951 external w...

Page 21: ...nfigurable Prefixes and Suffixes SNI Beetle Mode AT Keyboard Type XT Keyboard Type PS2 Keyboard USA Keyboard Belgium Keyboard France Keyboard Germany Keyboard Spain Keyboard Italy Keyboard UK Keyboard IBM KDB4700 Financial Keyboard Alt Mode Auto Detection or Caps Lock User Defined Caps Lock F0H Break Code Transmission 800 Microsecond Delay Enter Scan Code 15 Millisecond Delay Enter Scan Code 7 5 M...

Page 22: ... of a PFET type transistor that can source approximately 100 mA of current This output is the connection for an LED or other indicator i e beeper It is recommended that the indicator is terminated directly to ground 10 Beeper Input Collector of an NPN transistor that can sink approximately 100 mA of current A current limiting pull up resistor and Piezo type transducer QMB 111PXN or equivalent is r...

Page 23: ...ut 5V high with a 2 kHz pulse This drain is the pin of a PFET type transistor that can source approximately 100 mA of current This output is the connection for an LED or other indicator i e beeper It is recommended that the indicator is terminated directly to ground 10 Beeper Input Collector of an NPN transistor that can sink approximately 100 mA of current A current limiting pull up resistor and ...

Page 24: ...ine Nominal 12V signals 8 CTS Input RS232 Clear to send signal from host Nominal 12V signals 9 Good Read Indicator Output 5V high with a 2 kHz pulse This drain is the pin of a PFET type transistor that can source approximately 100 mA of current This output is the connection for an LED or other indicator i e beeper It is recommended that the indicator is terminated directly to ground 10 Beeper Inpu...

Page 25: ...ndicator Output 5V high with a 2 kHz pulse This drain is the pin of a PFET type transistor that can source approximately 100 mA of current This output is the connection for an LED or other indicator i e beeper It is recommended that the indicator is terminated directly to ground 10 Beeper Input Collector of an NPN transistor that can sink approximately 100 mA of current A current limiting pull up ...

Page 26: ...n mode 4 Scan Sense TTL output The signal pulses high once for each scan cycle i e one scan in each direction There are 35 scan pulses per second 5 Scan Mode Indicator Open collector active low output This pin will go low whenever the scan mode is activated It is capable of sinking 15 mA and can be used to activate an indicator light 6 Object Dectection Enable Do not connect to this pin 7 Ground P...

Page 27: ... right from the scanner perspective The HIGH to LOW transition of the SCAN SENSE signal initiates the start of the flip cycle The frequency of the SCAN SENSE pulses is dependent on the frequency of the internal flipper This varies from unit to unit from 26 Hz to 30 Hz Therefore the period of the SCAN SENSE pulses will vary from 33 ms to 39 ms Figure 12 Timing Diagram 23 ...

Page 28: ...res that all laser products introduced into commerce in the United States be registered with the CDRH US Food and Drug Administration through submittal of a Laser Safety Report The manufacturer of the end equipment must obtain approval and certification from agencies such as the FDA The specifications required for agency approval are not obtainable until the ScanQuest engine is used in its final c...

Page 29: ...ay impose additional testing certification requirements EMC The IS4125 has been tested to meet Class B EMC Standards The integrator is responsible to maintain proper EMC techniques to maintain this performance level Certain combinations of ScanQuest scan engines and associated electronics may require certification of compliance with the European EMC Directive EMC compliance of finished products in...

Page 30: ... on line from www access gpo gov su_docs or writing to Superintendent of Documents PO Box 371954 Pittsburgh PA 15250 7954 Note State and local governments may regulate the use products containing lasers The manufacturer should consult the applicable government regulations for more information EMC The IS4125 has been tested to meet Class B EMC Standards The integrator is responsible to maintain pro...

Page 31: ...efore do not incorporate a laser beam timeout This feature is necessary for compliance to CDRH Class II and or IEC Class 2 unless laser product modifications that change the requirement are made German WARNUNG Die Scanner IS4110 verfügen über keinen Steuerungsschaltkreis und daher auch nicht über einen Timeout des Laserstrahls Diese Eigenschaft ist jedoch nötig zur Konformität mit den Normen CDRH ...

Page 32: ...PT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT HII S RESPONSIBILITY AND PURCHASER S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLAC...

Page 33: ...29 PATENTS For patent information please refer to www honeywellaidc com patents ...

Page 34: ... Electrical Specifications 7 F FDA 1 26 27 Flex Ribbon Cable 2 3 Functions 12 17 G Green LED 2 Ground 18 22 H Host 1 17 I IEC 6 7 8 Indicators LED 2 18 22 Interfaces 6 7 8 Introduction 1 IR Sensor 1 3 K Keyboard Wedge 5 12 17 18 Kit demo 2 L Labels 4 LED 2 Light Pen Emulation 5 6 7 8 12 17 20 Light Source 6 7 8 Long Range Mode 5 17 22 M Maintenance 4 6 7 8 Mechanical 7 N Non Decode 1 2 5 NPN 18 19...

Page 35: ...1 S Scan Field 1 5 Scan Lines 6 7 8 Scan Pattern 6 7 8 Scan Sense 22 Scan Sense Timing 23 Scan Speed 6 7 8 Short Range Mode 5 Specifications 6 7 8 11 Standby current 7 Supplemental Window 11 System Interfaces 1 5 6 7 8 T Termination 7 Transducer 2 TTL 5 12 17 21 22 U UL 6 7 8 USB 5 19 V VCC 18 22 Voltage 7 W Warnings 27 Warranty 28 Weight 7 8 Window 6 7 8 11 Z ZIF 2 7 18 22 ...

Page 36: ... com Mexico Telephone 803 835 8000 E mail hsmlasupport honeywell com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail hsmeurosupport honeywell com Hong Kong Telephone 852 29536436 Fax 851 2511 3557 E mail aptechsupport honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail aptechsupport honeywell com China Telephone 86 800 828 2803 Fax 86 512 676...

Page 37: ... 21 3535 9100 Fax 55 21 3535 9105 E mail brservice honeywell com Mexico Telephone 52 55 5203 2100 Fax 52 55 5531 3672 E mail mxservice honeywell com Europe Middle East and Africa Telephone 31 0 40 2901 633 Fax 31 0 40 2901 631 E mail euroservice honeywell com Hong Kong Telephone 852 29536436 Fax 851 2511 3557 E mail apservice honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail a...

Page 38: ......

Page 39: ......

Page 40: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 00 02257 Rev E May 2010 ...

Reviews: