6
Honeywell Sensing and Control
PX2 Series Heavy Duty Presssure Transducers
ISSUE 8
50052336
Figure 3. Electrical Connector Type Dimensions (continued)
D
Deutsch
(DTM04-3P)
E
Cable Harness, 1 Meter
2
F
Cable Harness, 2 Meter
2
G
Cable Harness, 3 Meter
2, 3
H
Cable Harness, 5 Meter
2, 3
Connector:
Deutsch DTM04-3P
Mating Connector:
DTM06-3S
IP Rating
1
:
IP65, IP67, IP69K (absolute,
sealed gage versions)
IP65 (vented gage versions)
Connector:
24 AWG with TPE jacket
Mating Connector:
Flying leads
IP Rating
1
:
IP65, IP67, IP69K (absolute, sealed gage versions)
Pin
Voltage
Output
Current
Output
Wire Color
Voltage
Output
Wire Color
Current
Output
1
GND
RTN
red
V+
red
supply
2
Vout
NC
black
GND
black
RTN
3
V+
supply
white
Vout
Notes:
1. IP rating is determined by the electrical connector type chosen.
2. Three-wire cable is required for ratiometric and regulated outputs; two wire cable is required for current output.
3. Three meter and five meter cables are only available with Output Transfer Function
CH
= Current, 4 mA to 20 mA.
Hole
(vented gage