PS1202A REPLACEMENT POWER SUPPLY KIT FOR ELECTRONIC AIR CLEANER

69-1136EF—01

6

Modification To Reduce Ozone 

Odor

WARNING

ELECTRIC SHOCK HAZARD.

Can Cause Personal Injury

Always disconnect power before opening power  

supply cover.

The electronic air cleaner generates a small amount of 

ozone in normal operation. During the first or second 

week of operation, the amount may be higher because of 

sharp edges on some of the new high voltage metal parts. 

Normal use quickly dulls these edges.

The average person can detect the odor of ozone in 

concentrations as low as 0.003 to 0.010 parts per million 

(ppm). The electronic air cleaner contributes 0.005 to 

0.010 ppm of ozone to the indoor air. The U.S. Food and 

Drug Administration and Health and Welfare Canada 

recommend that indoor ozone concentration does not 

exceed 0.050 ppm. As a comparison, the outdoor ozone 

level in major cities is sometimes as high as 0.100 ppm.

However, if desired, the ozone generated by the air 

cleaner can be reduced in one of two ways:

1.

Install an activated carbon filter downstream from 

the air cleaner. Make sure particles from the air filter 

cannot fall into the air cleaner.

WARNING

ELECTRIC SHOCK HAZARD.

Can Cause Personal Injury.

Only a trained service technician should perform 
the following procedure.

2.

To reduce ozone production about 20 to 25 percent 

and reduce efficiency about seven to ten percent, 

depending on actual airflow delivered by the fur-

nace blower:

a. Unplug or disconnect power supply to the air 

cleaner.

b. Open the access door.

c. Remove the power box cover. See Fig. 1.

d. Locate J8 shorting bar on the power supply. See 

Fig. 8. Remove the shorting bar and reinstall on 

only one pin.

NOTE: The ozone will be reduced, and the short-

ing bar is available for reinstallation, if 

needed.

e. Replace the power supply cover and access 

door. Turn on the power.

f. Repeat the checkout procedure before leaving 

the job.

Fig. 8. Move J8 shorting bar to reduce ozone 

production about 20 to 25 percent.

M33490

5

P4

P1

P2

J3

J4

J8

P3

2.1mA

1.65mA

1.29mA

1.05mA

0.9mA

0.25mA

P5

T1

U4

8150V

7500V

P8

E6

E4

E5

E3

E1

E2

J1

J8 SHUNT IN OZONE

REDUCED POSITION

J8 SHUNT IN 

NORMAL POSITION

J8

J8

J4

J4

J4 SHUNT IN 

POSITION TO DISABLE 

NEON LIGHT OUTPUT

J4 SHUNT IN POSITION

TO ENABLE NEON 

LIGHT OUTPUT

Summary of Contents for PS1202A

Page 1: ... damage the product or cause a hazard ous condition such as electrical shock 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions WARNING ELECTRICAL HAZARD Can Cause Electric...

Page 2: ...onnect power for directly wired devices See Fig 3 or 4 for internal schematic The air cleaner operates correctly at any fan speed on a multispeed or modulated speed system wired with conduit or plugged in NOTE To reduce the risk of electric shock this product has a grounding type plug with a third grounding pin This plug fits only into a grounding type power outlet If the plug does not fit into th...

Page 3: ...GOES TO TOP TERMINAL AND BLACK LEAD TO BOTTOM TERMINAL M15096B 2 4 BLACK RED CONTACT BOARD RED IONIZER BLACK COLLECTOR BLACK 5 BLACK BLACK BROWN BLACK GREEN 3 1 P4 P1 P2 J3 POWER SUPPLY J4 J8 P3 2 1mA 1 65mA 1 29mA 1 05mA 0 9mA 0 25mA P5 T1 U4 8150V 7500V P8 E6 E4 E5 E3 E1 E2 J1 J2 J1 5 3 2 1 BLACK WHITE GROUND CHOKE P4 P1 P2 J3 POWER SUPPLY J4 J1 P3 2 1mA 1 65mA 1 29mA 1 05mA 0 9mA 0 25mA P5 T1 U...

Page 4: ...mal Test Button When pushed the test button shorts from collector voltage to ground The resulting arcing sound indicates that high voltage is being supplied to the collector The solid state power supply controls current flow to the collector On air cleaners with a W8600E the CHECK LED comes on when the test button is held down Fig 6 Use an ohmmeter to check the electronic cells for short circuits ...

Page 5: ...WIRING BETWEEN W8600E AND AIR CLEANER USE MAX NO 18 4 WIRE THERMOSTAT CABLE CONNECTED 1 G TO 1 G 2 Y TO 2 Y 3 R TO 3 R AND 4 B TO 4 B WIRING OK CORRECT WIRING REPLACE W8600E 3 CHECK FOR CORRECT INPUT VOLTAGE ACROSS P1 AND P2 TERMINALS ON POWER SUPPLY INSPECT CELL S FOR BENT COLLECTOR PLATES BROKEN IONIZER WIRES DIRT ON INSULATORS DAMAGED IONIZER OR COLLECTOR CONTACT TABS YES NO YES NO FIX WIRING R...

Page 6: ...d carbon filter downstream from the air cleaner Make sure particles from the air filter cannot fall into the air cleaner WARNING ELECTRIC SHOCK HAZARD Can Cause Personal Injury Only a trained service technician should perform the following procedure 2 To reduce ozone production about 20 to 25 percent and reduce efficiency about seven to ten percent depending on actual airflow delivered by the fur ...

Page 7: ... or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage that occurred while the product was in the possession of a consumer Honeywell sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CO...

Page 8: ...C AIR CLEANER Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 customer honeywell com U S Registered Trademark 2012 Honeywell International Inc 69 1136EF 01 M S 03 12 Printed in United States ...

Page 9: ...ement de P5 INSTALLATION Lors de l installation de ce produit 1 Lire attentivement ces instructions Le non respect des instructions peut endommager le produit ou provoquer une situation dangereuse telle que des chocs électriques 2 Vérifier les caractéristiques nominales indiquées dans les instructions et sur le produit pour s assurer que le produit correspond bien à l appli cation prévue 3 L insta...

Page 10: ...on Brancher les fils aux bornes du nouveau bloc IMPORTANT Ne pas épisser les fils de l ionisateur et du collecteur Ces fils doivent être intacts pour éviter les chocs électriques par le connecteur ou le ruban couvrant l épissure Brancher l épurateur d air électronique directement dans la prise de tension et de fréquence correctes ou rétablir l alimentation pour les dispositifs directement câblés V...

Page 11: ... et F58F avec W8600E NOIR 1 2 3 4 1 2 3 4 BORNIER AVANT ARRIÈRE VERS PANNEAU MURAL W8600E W4 W2 W1 W3 TABLEAU DE COMMUTATEUR DE DÉBIT D AIR ORANGE GRIS VIOLET NOIR 1 INTERRUPTEUR DE VERROUILLAGE 2 CAVALIER DE RÉDUCTION D OZONE 3 CAVALIER DE DÉSACTIVATION DE COMMUTATEUR DE DÉBIT D AIR 4 UNITÉ À UNE CELLULE SIMILAIRE MAIS AVEC UNE CELLULE SEULEMENT 5 BORNES P1 P2 SUR MODÈLES 120 V SEULEMENT LES CONN...

Page 12: ...NOIR NOIR MARRON L1 L2 NOIR VERT 3 1 J1 J2 VERT JAUNE ROUGE BLEU NOIR ROUGE PLAQUE À CONTACTS IONISATEUR ROUGE COLLECTEUR NOIR J8 INDUCTEUR DE TERRE 2 NOIR B4 R3 Y2 G1 1 2 3 5 W4 W2 W1 W3 TABLEAU DE COMMUTATEUR DE DÉBIT D AIR ORANGE GRIS VIOLET NOIR 1 INTERRUPTEUR DE VERROUILLAGE 2 CAVALIER DE RÉDUCTION D OZONE 3 CAVALIER DE DÉSACTIVATION DE COMMUTATEUR DE DÉBIT D AIR 4 ENTRAÎNEMENT DE L INDICATEU...

Page 13: ...lecteur Sur les épurateurs avec W8600E la DEL Vérification s allume lorsque le bouton de test est maintenu pressé Fig 6 Utiliser un ohmmètre pour vérifier l absence de court circuit au niveau des cellules électroniques DEL Vérification épurateurs d air avec W8600E La DEL Vérification sur le W8600E s allume pour indiquer les problèmes suivants accumulation excessive de saleté supérieure à celle req...

Page 14: ... 1 G À 1 G 2 Y À 2 Y 3 R À 3 R ET 4 B À 4 B CÂBLAGE OK CÂBLAGE OK REMPLACER LE W8600E 3 VÉRIFIER QUE LA TENSION D ENTRÉE EST CORRECTE ENTRE LES BORNES P1 ET P2 DU TABLEAU D ALIMENTATION INSPECTER LA OU LES CELLULES POUR DÉTECTER LES PROBLÈMES SUIVANTS PLAQUES DE COLLECTEUR COURBÉES FILS D IONISATEUR CASSÉS SALETÉ SUR LES ISOLATEURS LANGUETTES DE CONTACT DE COLLECTEUR OU IONISATEUR ENDOMMAGÉES OUI ...

Page 15: ... l épurateur d air b Ouvrir la porte d accès c Retirer le couvercle du boîtier d alimentation Voir la Fig 1 d Repérer la tige de court circuit J8 sur le bloc d alimentation Voir la Fig 8 Retirer la tige de court circuit et la réinstaller sur une seule broche REMARQUE L ozone sera réduit et la tige de court circuit peut être réinstallée ultérieurement si nécessaire e Replacer le couvercle et la por...

Page 16: ...0 1885 Douglas Drive Golden Valley MN 55422 La présente garantie ne couvre pas les frais de retrait ou de réinstallation La présente garantie ne s appliquera pas s il est démontré par Honeywell que la panne ou le mauvais fonctionnement sont dus à un endommagement du produit alors que le consommateur l avait en sa possession La responsabilité exclusive de Honeywell se limite à réparer ou à remplace...

Reviews: