RTH6350/RTH6450/RET93E0/RET95E0 Series
15 69-2696ES—03
SETUP
WIRING
ASSIST
ANCE
TROUBLESHOOTING
Function 2:
Heat pump changeover valve
Done
Next
2
0
M28352
Press the
s
or
t
button to select whether your change-
over valve is used in heating or cooling:
NOTE:
If Function 2 does not appear, please turn to the
next page to continue.
0
Cooling changeover valve:
Use this setting if you
connected a wire labeled “O” to the O/B wire terminal
(see page 23).
1
Heating changeover valve:
Use this setting if you
connected a wire labeled “B” to the O/B wire terminal
(see page 23).
M28351
Press to change setting.
When correct setting is
selected, press
NEXT
to
display next function.