Resideo Inc., 1985 Douglas Drive North
Golden Valley, MN 55422
www.resideo.com
©2019 Resideo Technologies, Inc. This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-633-3991
The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved.
33-00423EFS—03 M.S. Rev. 03-19
Printed in U.S.A.
CAUTION: MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash.
Contact your local waste management authority for instructions regarding recycling and proper disposal.
CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor
quickly.
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
Temperature Ranges
Heat: 40 °F to 90 °F (4.5 °C to 32.0 °C)
Cool: 50 °F to 99 °F (10.0 °C to 37.0 °C)
Operating Ambient Temperature
32 °F to 120 °F (0 °C to 48.9 °C)
Shipping Temperature
-20 °F to 120 °F (-28.9 °C to 48.9 °C)
Operating Relative Humidity
5% to 90% (non-condensing)
Physical Dimensions in inches (mm) (H x W x D)
T10 PRO Wi-Fi Thermostat:
4.9" x 3.7" x 0.93" (125.4 x 94.1 x 23.68)
UWP Mounting System (included):
2-9/32" x 2-13/64" x 2-43/64" (58 x 56 x 10)
Standard Installation Adapter (included):
3-29/32" x 3-57/64" x 21/32" (99 x 99 x 17)
Cover Plate – Medium (included):
5-11/64" x 5-1/2" x 11/16" (131.4 x 139.7 x 17.5)
Cover Plate – Large (THP2400A1068):
6-7/64" x 6-7/64" x 9/32" (155 x 155 x 7)
Specifications
Electrical Ratings
Terminal
Voltage
(50/60Hz)
Running
Current
W
Heating
20-30 Vac
0.02-1.0 A
(Powerpile)
750 mV DC
100 mA DC
W2
(Aux) Heating
20-30 Vac
0.02-1.0 A
E
Emergency Heat
20-30 Vac
0.02-0.5 A
Y
Compressor Stage 1
20-30 Vac
0.02-1.0 A
Y2
Compressor Stage 2
20-30 Vac
0.02-1.0 A
G
Fan
20-30 Vac
0.02-0.5 A
O/B
Changeover
20-30 Vac
0.02-0.5 A
L/A
Input
20-30 Vac
0.02-0.5 A
U
20-30 Vac
0.02-0.5 A
Power Consumption
3 VA
5-year limited warranty
Regulatory information
FCC REGULATIONS
§ 15.19 (a)(3)
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions:
1 This device may not cause harmful interference, and
2 This device must accept any interference received,
including interference that may cause undesired operation.
IC REGULATIONS
RSS-GEN
This device complies with Industry Canada’s license-exempt
RSSs.
Operation is subject to the following two conditions:
1 This device may not cause interference; and
2 This device must accept any interference, including
interference that may cause undesired operation of the
device.
FCC Warning (Part 15.21) (USA only)
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment.
The product should not be disposed of with other household
waste. Check for the nearest authorized collection centers
or authorized recyclers. The correct disposal of end-of-life
equipment will help prevent potential negative consequences
for the environment and human health.
For Warranty information go to
http://honeywellhome.com
Summary of Contents for pro Series
Page 43: ...15 ...