12
PRO-2200 Enclosure PRO22ENC1 & PRO22ENC2
Installation Guide
UL1076 Setup
PC Minimum Requirements
Two required:
• 500 Mhz
• 128Mb RAM
• 9.1Gb hard drive
• CD ROM
• 10/100 TX network card
• 17” SVGA Monitor
Peripheral Hardware Requirements
• UL approved network HUB with at least 4 ports.
• UL approved CAT 5 network cable and connectors.
• PRO22IC Controller and accompanying I/O boards.
• Cobox network card (PRO22IC mounted)
Operating System Requirements
• NT Server 4.0 or better.
• NT Service Pack #5 or higher.
Software Packages Required
• SQL Server 7.0
• SQL Server Service Pack #1 or higher.
• WIN-PAK PRO 3.0 with SQL database selection.
Receiving Unit minimum configuration
• PRO22ENC1 or PRO22ENC2 cabinet
• PRO22ULPS (ALTRONIX AL400 ULX) power supply with 40 AH battery back up
• PRO22IC controller panel
• PRO22IN input panel
• PRO22EN Cobox Ethernet card
• PRO22ENSP Tripp Lite DNET1 Ethernet surge protector
The following priority of incoming signals must be used for UL1076
1. Fire alarm (N/A) WIN PAK PRO is not certified for fire alarm supervision
2. Hold up / Panic alarm
3. Burglar alarm
Summary of Contents for PRO-2200
Page 1: ...PRO 2200 Enclosure Installation Manual Part Number PRO22ENC1 PRO22ENC2 TD1138 rev0801 ...
Page 20: ...PRO 2200 Enclosure PRO22ENC1 PRO22ENC2 21 Installation Guide NOTES ...
Page 21: ...22 PRO 2200 Enclosure PRO22ENC1 PRO22ENC2 Installation Guide NOTES ...