background image

 
 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

DoP

 

available

 

on

 

web

 

site

 

www.notifier.it

 

 

 
 

 
 

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

      

1293

 

Notifier

 

s.r.l.

  

Via

 

A:

 

Grandi,

 

22,

 

20097

 

S.

 

Donato

 

Milanese

 

(MI)

 

Italy

17

 

DoP

 

1293

 ‐ 

CPR

 ‐ 

0600

 

EN54

3

 

DSE1

PW

  ‐ 

FIRE

 

ALARM

 

SOUNDER

 

Intended

 

for

 

use

 

in

 

fire

 

detection

 

and

 

fire

 

alarm

 

systems

 

in

 

and

 

around

 

buildings

 

TYPE

 

B:

 

for

 

outdoor

 

use

 

Other

 

technical

 

data:

 

see

 

the

 

supplier’s

 

technical

 

dossier.

  

Essential

 

characteristics

 

Performance

 

Performance

 

under

 

fire

 

conditions

 

Pass

 

Operational

 

reliability

 

Pass

 

Durability

 

of

 

operational

 

reliability

 

and

 

response

 

delay,

 

temperature

 

resistance

 

Pass

 

Durability

 

of

 

operational

 

reliability,

 

humidity

 

resistance

Pass

Durability

 

of

 

operational

 

reliability,

 

shock

 

and

 

vibration

 

resistance

Pass

Durability

 

of

 

operational

 

reliability,

 

corrosion

 

resistance

 

Pass

 

Durability

 

of

 

operational

 

reliability,

 

electrical

 

stability

Pass

Durability

 

of

 

operational

 

reliability,

 

resistance

 

to

 

ingress

Pass

ATTENTION:

Please

 

note

 

that

 

all

 

installation

 

indications

 

here

 

above

 

must

 

be

 

carefully

 

respected

 

to

 

prevent

 

the

 

device

 

from

 

loosing

 

its

 

standard

 

compliance.

 

 
 
 

SISTEMA GESTIONE 

QUALITÀ E AMBIENTE 

CERTIFICATI 

UNI EN ISO 9001:2008 

UNI EN ISO 14001:2004 

 - 

 

 

Warranty:

 

All

 

Notifier

 

products

 

have

 

1

 

year

 

warranty.

Summary of Contents for Notifier DSE1-PW

Page 1: ... degree IP 44 Environmental degree IV outdoor Operating temperature from 25 to 55 C Timing Programmable see chart Command from the control panel Polarity inversion Size 330x210x115 H x L x D Weight 2 300 gr Standards EN 54 3 2001 A1 2002 A2 2006 DSE1 PW sounder description remote supplied 24Vdc sounder with high brightness low consumption LED flashing unit programmable alarms and timings flash and...

Page 2: ...control panel to each terminal B SIX WIRE CONNECTION Connect the lines output to each terminal EOL GND 0V 24V CONTROL PANEL STAND BY ALARM 24V GND 0V GND 0V 24V SOUND 2 CONTROL PANEL EOL SOUND 1 STAND BY ALARM 24V GND 0V EOL EOL SOUND 3 GND 0V 24V GND V0 24V 24V GND 0V 24V GND 0V ...

Page 3: ...LYING TO EN54 3 OFF ON 8 MINUTES NOT COMPLYING TO EN54 3 ON ON 15 MINUTES NOT COMPLYING TO EN54 3 CHART 5 LED FLASHING UNIT DIP4 LEDs MODE OFF STEADY ON ON FLASHING CHART 4 FLASHING SELECTION DIP 3 FLASH CONTROL OFF FLASH CONTROLLED BY ALARM INPUTS ON FLASH CONTROLLED BY M9 TEST INPUT CHART 6 AVERAGE CURRENT SELECTION ONLY SOUND Average Peak mA With FLASHING add 80mA to the value on the chart DIP ...

Page 4: ...82 105 84 102 50 106 76 95 90 Note When Synchronism is used the same Alarm Timing and Sound pattern Selection in every sounder connected must be used DSE1 PW vertical DIP 5 OFF 6 OFF 7 OFF DIP 5 ON 6 OFF 7 OFF 100mA 100mA S1 S2 S3 S1 S2 S3 min dB A 1m min dB A 1m min dB A 1m min dB A 1m min dB A 1m min dB A 1m 15 92 54 96 12 93 56 87 40 90 84 90 79 45 96 74 98 44 95 44 86 84 95 24 88 14 75 99 91 1...

Page 5: ...ntrol panel 5 Close the internal and external covers with the screws provided WARNING The power supply must be of SELV type Note to avoid formation of condensation inside the sounder any air flow must be avoided Once the cables have been connected seal the hole using some silicone This operation will prevent the warm and humid air of the building from forming condensation inside the sounder during...

Page 6: ... and response delay temperature resistance Pass Durability of operational reliability humidity resistance Pass Durability of operational reliability shock and vibration resistance Pass Durability of operational reliability corrosion resistance Pass Durability of operational reliability electrical stability Pass Durability of operational reliability resistance to ingress Pass ATTENTION Please note ...