CONNECTION

 

SCHEME

 

 

A

 

 

TWO

WIRE

 

CONNECTION

 

Connect

 

the

 

24V

 

power

 

supply

 

from

 

the

 

control

 

panel

 

to

 

each

 

terminal:

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

SIX

WIRE

 

CONNECTION

 

 

Connect

 

the

 

lines

 

output

 

to

 

each

 

terminal:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EO
L

 

GND 0V => +24V  

CONTROL 

PANEL 

STA

N

D

 

BY

 

AL

A

R

M

 

  +24V     => GND 0V    

GND 0V => +24V    

SOUND 2 

CONTROL 

PANEL 

EOL

 

SOUND 1 

STAND

 

BY

 

AL

ARM

 

+24V =>    GND 0V 

EOL

 

EOL

SOUND 3 

GND 0V  => +24V    

GND V0  => +24V    

+24V =>    GND 0V 

+24V =>    GND 0V 

Summary of Contents for Notifier DSE1-PW

Page 1: ... degree IP 44 Environmental degree IV outdoor Operating temperature from 25 to 55 C Timing Programmable see chart Command from the control panel Polarity inversion Size 330x210x115 H x L x D Weight 2 300 gr Standards EN 54 3 2001 A1 2002 A2 2006 DSE1 PW sounder description remote supplied 24Vdc sounder with high brightness low consumption LED flashing unit programmable alarms and timings flash and...

Page 2: ...control panel to each terminal B SIX WIRE CONNECTION Connect the lines output to each terminal EOL GND 0V 24V CONTROL PANEL STAND BY ALARM 24V GND 0V GND 0V 24V SOUND 2 CONTROL PANEL EOL SOUND 1 STAND BY ALARM 24V GND 0V EOL EOL SOUND 3 GND 0V 24V GND V0 24V 24V GND 0V 24V GND 0V ...

Page 3: ...LYING TO EN54 3 OFF ON 8 MINUTES NOT COMPLYING TO EN54 3 ON ON 15 MINUTES NOT COMPLYING TO EN54 3 CHART 5 LED FLASHING UNIT DIP4 LEDs MODE OFF STEADY ON ON FLASHING CHART 4 FLASHING SELECTION DIP 3 FLASH CONTROL OFF FLASH CONTROLLED BY ALARM INPUTS ON FLASH CONTROLLED BY M9 TEST INPUT CHART 6 AVERAGE CURRENT SELECTION ONLY SOUND Average Peak mA With FLASHING add 80mA to the value on the chart DIP ...

Page 4: ...82 105 84 102 50 106 76 95 90 Note When Synchronism is used the same Alarm Timing and Sound pattern Selection in every sounder connected must be used DSE1 PW vertical DIP 5 OFF 6 OFF 7 OFF DIP 5 ON 6 OFF 7 OFF 100mA 100mA S1 S2 S3 S1 S2 S3 min dB A 1m min dB A 1m min dB A 1m min dB A 1m min dB A 1m min dB A 1m 15 92 54 96 12 93 56 87 40 90 84 90 79 45 96 74 98 44 95 44 86 84 95 24 88 14 75 99 91 1...

Page 5: ...ntrol panel 5 Close the internal and external covers with the screws provided WARNING The power supply must be of SELV type Note to avoid formation of condensation inside the sounder any air flow must be avoided Once the cables have been connected seal the hole using some silicone This operation will prevent the warm and humid air of the building from forming condensation inside the sounder during...

Page 6: ... and response delay temperature resistance Pass Durability of operational reliability humidity resistance Pass Durability of operational reliability shock and vibration resistance Pass Durability of operational reliability corrosion resistance Pass Durability of operational reliability electrical stability Pass Durability of operational reliability resistance to ingress Pass ATTENTION Please note ...