background image

 

 

13

C

ODE 

T

YPES AND 

D

ECODE 

R

ULES

 

 

C

ONFIGURABLE 

C

ODE 

L

ENGTHS

 

 

³

9

0

3

0

0

0

 

~  Code Length Lock #6 

³

9

0

3

1

0

0

 

~  Code Type Lock #6 

³

9

0

3

2

0

0

 

~  Code Length Lock #7. 

³

9

0

3

3

0

0

 

~  Code Type Lock #7. 

 
 
 
 
 

³

1

2

4

7

1

3

 

Enable Japanese Multi-Field 

³

1

2

4

7

0

3

 

Disable Japanese Multi-Field 

Summary of Contents for MS9544

Page 1: ...o com Monday Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING SE Habla Español Free ground shipping to the continental USA on orders over 100 For Help Call 1 800 241 6264 Honeywell MS9540 Manual THIS DOWNLOAD APPLIES TO THE FOLLOWING MS9540 Voyager Codegate MS9541 Voyager HD ...

Page 2: ...METROLOGIC INSTRUMENTS INC MetroSelect Single Line Configuration Guide ...

Page 3: ...prior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Trademarks Metrologic is a registered trademark of Metrologic Instruments Inc Products identified in this document are hereby acknowledged as trademarks registered or otherwise of Metrologic Instruments Inc or their respective companies ...

Page 4: ...nal Decode Features 11 Configurable Code Lengths 12 Supplements 14 RSS Bar Code Implementation RSS Limited Bar Codes 20 RSS Expanded Bar Codes 20 ISBT Code 128 Implementation Configuration Mode Bar Codes 21 Concatenation Configuration Mode Bar Codes 22 Pre Defined Concatenation Configuration Mode Bar Codes 22 User Defined Concatenation Configuration Mode Bar Codes 23 Communications 25 Scanner Oper...

Page 5: ...cters Code Specific 37 Standard Prefix Characters 39 Standard Suffix Characters 41 Longitudinal Redundancy Check 42 Block Check Character 42 Character Replacements 43 User Configurable Suffixes All Data 44 Special Formats 45 Code Formatting UPC EAN Formatting 46 Codabar Formatting 48 Code 39 Formatting 49 Code 11 Formatting 49 Telepen 49 Plessey 50 2 of 5 Code Formatting 50 RS232 Parity Features 5...

Page 6: ...5 MS9520 9540 00 Laser Emulation Mode 66 IBM 46xx Configuration IBM Port 67 IBM Reserve Codes 67 USB 68 Code Bytes Usage Code Bytes 0 9 70 Reserved Codes 71 Code Type Table 71 ASCII Reference Table 72 Extended Key Code Reference Table 76 MS9520 Voyager MS9540 VoyagerCG Series Activation Range 78 Stand Scan Modes 78 CodeGate Status 78 Laser Scan Modes 79 Same Symbol Time Outs 80 MS9524 MS9544 Voyag...

Page 7: ...v TABLE OF CONTENTS MS9535 VoyagerBT 83 MS9535 5M VoyagerBT 85 Inventory Quantity Bar Codes 87 IS4125 IS4225 Scan Engines 88 Miscellaneous Features Custom Defaults 89 Serial Program Mode 90 ...

Page 8: ...ault setting Bar codes with a tilde require the Multi Code configuration method BAR CODE CONFIGURATION METHODS The MetroSelect class of scanners can be bar code configured in two ways the Single Code Method and the Multi Code Method Please note that the MS6220 Pulsar can only be configured using the Multi Code Method To properly configure an MS9540 scanner all configuration codes must be scanned u...

Page 9: ...can be enabled disabled before scanning the enter exit configuration mode bar code 4 Scan the enter exit configuration mode bar code 3 beeps and save the new configuration To abort a configuration change power off the scanner before scanning the enter exit code Enter Exit Configuration Mode 9 9 9 9 9 9 NEED TO START OVER Scan the Recall Default bar code This will erase all previous settings and re...

Page 10: ...arked with a tilde require the Multi Code configuration method UPC EAN 1 0 0 1 1 6 Enable UPC EAN 1 0 0 1 0 6 Disable UPC EAN 1 0 0 2 1 6 Enable UPC A 1 0 0 2 0 6 Disable UPC A 1 0 0 2 1 0 Enable UPC E 1 0 0 2 0 0 Disable UPC E 1 0 0 2 1 1 Enable EAN 13 1 0 0 2 0 1 Disable EAN 13 1 0 0 2 1 4 Enable EAN 8 1 0 0 2 0 4 Disable EAN 8 ...

Page 11: ...ing 1 0 0 7 1 1 Ignore FNC4 Code 128 Characters 1 0 0 7 0 1 Use FNC4 to Determine Extended ASCII Characters CODE 39 1 0 0 1 1 1 Enable Code 39 1 0 0 1 0 1 Disable Code 39 1 0 0 2 1 3 Enable MOD 43 Check Digit on Code 39 The scanner only scans Code 39 bar codes that have a valid Modulo 43 check digit 1 0 0 2 0 3 Disable MOD 43 Check Digit on Code 39 1 0 0 2 1 7 Enable Full ASCII Code 39 1 0 0 2 0 7...

Page 12: ...I OPTIC Code 1 0 0 3 0 2 Disable TRI OPTIC Code 1 0 0 7 0 2 Use Standard Code 39 Framing 1 0 0 7 1 2 Try Code 39 Codes Without 5 Bar Multiples 1 0 0 4 1 6 Enable ITF Code 39 Filters 1 0 0 4 0 6 Disable ITF Code 39 Filters 1 0 0 9 1 4 Enable Self Service Library Code 39 1 0 0 9 0 4 Disable Self Service Library Code 39 1 0 7 7 1 5 Transmit MOD 43 Check Digit with Self Service Library Code 39 1 0 7 7...

Page 13: ... bar codes that have a Modulo 10 check digit 1 0 0 3 0 0 Disable MOD 10 Check on ITF 1 0 7 8 1 7 Allow ITF Null Characters 1 0 7 8 0 7 Do Not Allow ITF Null Characters 9 0 1 6 0 0 ITF Symbol Length Lock 1 To specify a 1st ITF symbol length lock scan this bar code and the appropriate code byte sequence located on page 70 9 0 1 7 0 0 ITF Symbol Length Lock 2 To specify a 2 nd ITF symbol length lock ...

Page 14: ...ber of characters to be decoded scan this bar code and the appropriate code byte sequence located on page 70 1 0 0 0 1 5 Enable Matrix 2 of 5 1 0 0 0 0 5 Disable Matrix 2 of 5 1 0 0 5 0 7 Enable Matrix 2 of 5 Check Digit Requirement 1 0 0 5 1 7 Disable Matrix 2 of 5 Check Digit Requirement 1 0 0 0 1 4 Enable 15 Digit Airline 2 of 5 1 0 0 0 0 4 Disable 15 Digit Airline 2 of 5 1 0 0 3 1 3 Enable 13 ...

Page 15: ...8 CODE TYPES AND DECODE RULES 2 OF 5 CODES 1 0 0 3 1 6 Enable Hong Kong 2 of 5 1 0 0 3 0 6 Disable Hong Kong 2 of 5 1 1 5 4 1 1 Enable Follett ITF 1 1 5 4 0 1 Disable Follett ITF ...

Page 16: ...Codabar CODE 93 1 0 0 1 1 2 Enable Code 93 1 0 0 1 0 2 Disable Code 93 CODE 11 1 0 0 0 1 3 Enable Code 11 1 0 0 0 0 3 Disable Code 11 1 0 8 0 0 5 Check for 1 Code 11 Check Digit 1 0 8 0 1 5 Check for 2 Code 11 Check Digits 1 0 8 0 0 4 Do Not Check for 2 Code 11 Check Digits 1 0 8 0 1 4 Check for 2 Code 11 Check Digits if Code Length is Greater Than 10 Characters ...

Page 17: ...essey Check Digit Plessey bar codes will not be tested for a check digit 2 0 0 7 3 4 Enable MSI Plessey MOD 10 10 Check Digit Test MSI Plessey bar codes for a 2 digit Modulo 10 check digit 2 0 0 7 2 4 Enable MSI Plessey MOD 10 Check Digit Test MSI Plessey bar codes for a 1 digit Modulo 10 check digit 1 0 0 1 1 7 Enable UK Plessey 1 0 0 1 0 7 Disable UK Plessey 1 0 0 7 1 6 Enabled UK Plessey A to X...

Page 18: ...Required 1 0 1 1 0 5 Disable Small Border 9 0 1 8 0 0 Minimum Symbol Length Single line default is 3 Combine this code with the proper code bytes on page 70 to specify the minimum number of characters in all non UPC EAN bar codes 9 0 1 9 0 0 Symbol Length Lock Combine this code with the proper code bytes to lock the bar code s length into place 1 1 9 4 1 7 Enable Modulus 8 Filter on Bar Space Coun...

Page 19: ...e length page 70 3 Scan the matching code type lock 1 bar code 4 Scan the three code bytes that represent the code type This process can be repeated for lock lengths 2 through 7 9 0 2 0 0 0 Code Length Lock 1 9 0 2 1 0 0 Code Type Lock 1 9 0 2 2 0 0 Code Length Lock 2 9 0 2 3 0 0 Code Type Lock 2 9 0 2 4 0 0 Code Length Lock 3 9 0 2 5 0 0 Code Type Lock 3 9 0 2 6 0 0 Code Length Lock 4 9 0 2 7 0 0...

Page 20: ...ES CONFIGURABLE CODE LENGTHS 9 0 3 0 0 0 Code Length Lock 6 9 0 3 1 0 0 Code Type Lock 6 9 0 3 2 0 0 Code Length Lock 7 9 0 3 3 0 0 Code Type Lock 7 1 2 4 7 1 3 Enable Japanese Multi Field 1 2 4 7 0 3 Disable Japanese Multi Field ...

Page 21: ...1 2 1 1 Enable Five Digit Redundancy The scanner will scan the bar code plus the 5 digit add on twice before accepting data 1 0 1 2 0 1 Disable Five Digit Redundancy 1 0 1 2 1 3 Supplements are Required All UPC EAN labels that are scanned must have a supplement 1 0 1 2 0 3 Supplements are Not Required 1 0 1 4 1 6 Enable Remote Supplement Required MS9500 MS6200 not supported 1 0 1 4 0 6 Disable Rem...

Page 22: ...ble 378 379 French Supplement Required 1 0 1 3 0 3 Disable 378 379 French Supplement Required 1 0 1 4 1 3 Enable 414 419 German Bookland Supplement Required 1 0 1 4 0 3 Disable 414 419 German Bookland Supplement Required 1 0 1 4 1 5 Enable 434 439 German Supplement Required 1 0 1 4 0 5 Disable 434 439 German Supplement Required 1 0 1 4 1 2 Enable System 2 Requires Supplements 1 0 1 4 0 2 Disable S...

Page 23: ...rtion of the coupon code 1 0 1 4 0 1 Disable Code 128 C1 Extended Code Format 1 0 1 4 1 4 Enable Code 128 Group Separators A GS 1DH character will be transmitted with coupon Code 128 codes 1 0 1 4 0 4 Disable Code 128 Group Separators 3 0 1 3 4 0 400 msec to Find Supplemental The scanner will allot 400 milliseconds to find an add on after a main UPC EAN bar code has been scanned 3 0 1 3 2 0 200 ms...

Page 24: ...with all models 1 0 1 3 0 5 Disable ISBN Check Digit Transmission 1 0 1 3 1 7 Enable Bookland to ISBN Conversion Not available with all models 1 0 1 3 0 7 Disable Bookland to ISBN Conversion 1 0 1 3 1 6 Enable ISBN Re Formatting 1 0 1 3 0 6 Disable ISBN Re Formatting 1 2 5 1 1 5 Enable Bookland to ISBN 979 Conversion 1 2 5 1 0 5 Disable Bookland to ISBN 979 Conversion 1 2 5 1 0 6 Normal ISBN Re Fo...

Page 25: ...able for MS9540 scanners only Requires standard Code Gate be inactive in and out of stand 1 0 1 2 0 0 CodeGate Does Not Affect Supplemental Scanning Available for MS9540 scanners only 1 2 5 0 1 7 No Supplement Checking if EAN 13 Code is just scanned 1 2 5 0 0 7 Normal Supplement Checking ...

Page 26: ...r further assistance 1 0 0 0 1 1 Double Border Required When scanning RSS bar codes it is recommended that double border requirements be enabled because of the large spaces often found in RSS symbologies 1 0 0 4 1 3 Enable RSS 14 1 0 0 4 0 3 Disable RSS 14 1 1 4 9 0 0 Transmit RSS 14 Check Digit 1 1 4 9 1 0 Do Not Transmit RSS 14 Check Digit 1 1 4 9 0 1 Transmit RSS 14 Application ID Application I...

Page 27: ... 01 is transmitted by default 1 1 4 9 1 4 Do Not Transmit RSS Limited Application ID 1 1 4 9 0 5 Transmit RSS Limited Symbology ID Symbology identifier e0 is transmitted by default 1 1 4 9 1 5 Do Not Transmit RSS Limited Symbology ID RSS EXPANDED BAR CODES 1 0 0 4 1 5 Enable RSS Expanded 1 0 0 4 0 5 Disable RSS Expanded 1 1 4 9 0 6 Transmit RSS Expanded Symbol ID Symbology identifier e0 is transmi...

Page 28: ...a characters are removed from the data stream ID characters unless the ISBT bar code scanned contains the Donation Identification Number identifiers In this instance only the first ID character is removed from the Donation ID Number The second is regarded as normal data 1 3 8 4 1 5 Don t Transmit ISBT ID s 1 3 8 4 0 5 Transmit ISBT Identifiers These bar codes are used to convert and transmit the M...

Page 29: ...tenation Sequence 3 0 1 3 7 0 700 msec to Find Concatenation Sequence PRE DEFINED CONCATENATION CONFIGURATION MODE BAR CODES Supported by the MS9500 series only The first two barcodes can be used to enable disable pre defined concatenation sequences The remaining bar codes enable the specific enable concatenation sequences and are not needed to enable concatenation They can be used to disable any ...

Page 30: ...ON CONFIGURATION MODE BAR CODES Supported by the MS9500 series only The first two bar codes can be used to enable disable user defined concatenation sequences The remaining bar codes are used to enter the user defined identifiers used in the concatenation sequence These bar codes require that the user enter configuration mode first Then after scanning the appropriate code follow the rules for usin...

Page 31: ... is now configured with the appropriate identifiers Since both ISBT and User defined Concatenation are enabled ISBT 128 bar codes scanned successively that contain these identifiers will be concatenated An alternate method of the type found in section 4 8 1 of the ISBT specifications can be used for configuring user defined concatenation sequences Using the previous example the identifiers can be ...

Page 32: ...on by converting the scanned bar code data to the PC keyboard scan code equivalent 9 9 9 9 9 3 Load OCIA Defaults Scan this code before selecting Enable OCIA output 4 1 5 5 4 4 Enable OCIA Output Select this option if the communications requirement is on Optically Coupled Interface Adapter OCIA This is a docked by the host serial interface 9 9 9 9 9 5 Load IBM 46xx Defaults 4 1 5 5 0 4 Enable IBM ...

Page 33: ...ng of configuration bar codes at any time SCAN BUFFERS 3 1 8 0 0 0 1 Scan Buffer The scanner will scan one bar code in the scan field and not scan again until the bar code is removed from the scan field for the duration of the same symbol time out 3 1 8 0 1 0 2 Scan Buffers The scanner will scan 2 bar codes in the scan field one time each These 2 bar codes will not be scanned again and until they ...

Page 34: ...Requires 5 consecutive decodes of the same bar code for a good scan 3 0 1 1 5 0 5 Redundant Scans Requires 6 consecutive decodes of the same bar code for a good scan 3 0 1 1 6 0 6 Redundant Scans Requires 7 consecutive decodes of the same bar code for a good scan 3 0 1 1 7 0 7 Redundant Scans Requires 8 consecutive decodes of the same bar code for a good scan MISCELLANEOUS DECODE FEATURES 1 1 8 1 ...

Page 35: ...0 for additional information 8 1 8 9 0 0 No Same Symbol Time Out 1 1 8 9 1 7 Infinite Same Symbol Time Out The scanner will not repetitively scan the same bar code This option overrides the symbol rescan time outs 1 1 9 4 1 4 Enable 2 Second Time Out after 2 seconds of inactivity the laser will turn off and stay off until the CodeGate button is pressed This feature is for the MS5145 only 1 1 9 4 0...

Page 36: ...5 Optional Tone 4 3 1 8 5 2 5 Optional Tone 5 3 1 8 5 1 5 Optional Tone 6 3 1 8 5 0 5 No Beep 1 1 8 4 0 6 Beep Once on Supplements 1 1 8 4 1 6 Beep Twice on Supplements 1 1 8 4 1 4 Enable Fast Beep 1 1 8 4 0 4 Disable Fast Beep 1 1 8 5 1 2 Enable Fun Tones scan this bar code then scan one of the Optional Tone bar codes above 1 1 8 5 0 2 Disable Fun Tones ...

Page 37: ...d 1 1 6 9 1 3 Enable Light Pen Toggle During Beep The scanner beeps and toggles the light pen data line on a successful decode This drives a good read indicator 1 1 6 9 0 3 Disable Light Pen Toggle During Beep 1 2 4 7 1 1 Enable Pass Through 1 2 4 7 0 1 Disable Pass Through 1 2 5 0 1 1 Beep with Pass Through Data 1 2 5 0 0 1 No Beep with Pass Through Data 1 2 5 0 1 0 Enable Record Count Capture 1 ...

Page 38: ... 8 1 8 8 1 0 0 10 msec Intercharacter Delay 8 1 8 8 2 5 0 25 msec Intercharacter Delay 9 1 8 8 0 0 Variable msec Intercharacter Delay Scan this bar code and a sequence of code bytes on page 70 to set the delay between characters sent to the host system range from 1 to 255 msecs 8 1 8 8 0 0 No Intercharacter Delay 9 1 9 3 0 0 Variable Inter Record Delay 1 1 9 3 1 7 Turn Off Laser During Inter Recor...

Page 39: ... 8 4 0 3 Beep After Transmit 9 1 9 1 0 0 Variable Communications Time Out 8 1 9 1 4 0 0 Default Communications Time Out 2 secs 8 1 9 1 2 0 0 Short Communications Time Out 1 secs 8 1 9 1 8 0 0 Long Communications Time Out 4 secs 1 1 8 4 1 0 Three Beeps on Time Out 1 1 8 4 0 0 No Beeps on Time Out 1 1 8 4 1 1 Razzberry Tone on Time Out 1 1 8 4 0 1 No Razzberry Tone on Time Out ...

Page 40: ...will turn off the laser after the scanner receives an ASCII F character The laser will turn on after it receives an ASCII L character 1 1 8 0 0 4 Disable F L Laser Command 1 1 8 1 1 5 Use DTR Scan Disable The scanner will monitor the DTR input to determine if scanning should be allowed A 12V active level enables decoding A 12V inactive level disables decoding 1 1 8 1 0 5 Do Not Use DTR Scan Disabl...

Page 41: ...1 1 1 Transmit NO READ if DC2 Activated 1 1 8 1 0 1 Do Not Transmit NO READ if DC2 Activated 1 1 8 3 1 1 No Green LED During NO READ Transmit 1 1 8 3 0 1 Green LED During NO READ Transmit 9 9 9 9 6 9 Transmit Serial Number 1 1 8 2 1 3 Enable Motor On Off Commands 1 1 8 2 0 3 Disable Motor On Off Commands 1 2 5 0 1 6 Disable RS232 Receive 1 2 5 0 0 6 Normal RS232 Receive 1 2 5 0 1 3 Enable Banco Co...

Page 42: ...n No Read TEST MODES 1 1 8 0 1 7 Scanability ON This option enters scanability test mode Do not enable unless instructed by a Metrologic representative 1 1 8 0 0 7 Scanability OFF 1 1 8 0 1 6 Scan Count Mode ON The scanner will enter scan count test mode and the scanner s firmware number will transmit to the host Do not enable unless instructed by a Metrologic representative 1 1 8 0 0 6 Scan Count...

Page 43: ... third configurable prefix character 9 0 3 8 0 0 Configurable Prefix Character 4 Assigns a fourth configurable prefix character 9 0 3 9 0 0 Configurable Prefix Character 5 Assigns a fifth configurable prefix character 9 0 4 0 0 0 Configurable Prefix Character 6 Assigns a sixth configurable prefix character 9 0 4 1 0 0 Configurable Prefix Character 7 Assigns a seventh configurable prefix character ...

Page 44: ...r the data If using suffixes user configured prefixes can not be used Enter configuration mode then scan this bar code followed by the three code byte bar codes on page 70 that represent a unique ID character to be associated with this bar code type 9 0 5 6 0 0 Configurable UPC A ID 9 0 5 7 0 0 Configurable UPC E ID 9 0 5 8 0 0 Configurable EAN 8 ID 9 0 5 9 0 0 Configurable EAN 13 ID 9 0 6 0 0 0 C...

Page 45: ...ble Standard 2 of 5 ID 9 0 6 7 0 0 Configurable Interleaved 2 of 5 ID 9 0 6 8 0 0 Configurable Matrix 2 of 5 ID 9 0 6 9 0 0 Configurable Airline 2 of 5 ID 9 0 6 5 0 0 Configurable MSI Plessey ID 9 0 7 0 0 0 Configurable UK Plessey ID 9 0 6 6 0 0 Configurable Codabar ID 9 9 9 9 8 3 Clear All Configurable Code Specific ID s Clears all unique ID characters previously identified 1 0 5 5 1 6 Enable Ter...

Page 46: ...ransmit a prefix before any UPC EAN bar code The prefixes are A UPC A E0 UPC E F EAN 13 and FF EAN 8 1 1 6 6 0 7 Disable UPC Prefix ID 1 0 7 9 1 1 Enable NCR Prefix ID The scanner will transmit a prefix before the following code types The prefixes are as follows A UPC A E0 UPC E FF EAN 8 F EAN 13 B1 Code 39 B2 ITF B3 Code 128 and other codes 1 0 7 9 0 1 Disable NCR Prefix ID 9 4 1 5 0 0 Enable NCR...

Page 47: ...ble Manufacturer ID Prefix 1 0 5 5 1 1 Enable C Prefix 1 0 5 5 0 1 Disable C Prefix 1 0 5 5 1 0 Enable Prefix ID for UPC EAN 1 0 5 5 0 0 Disable Prefix ID for UPC EAN 1 1 6 6 1 1 Enable Tab Prefix The scanner will transmit a TAB ASCII 09H before each bar code 1 1 6 6 0 1 Disable Tab Prefix 1 1 6 1 1 1 Enable SNI Beetle Mode 1 1 6 1 0 1 Disable SNI Beetle Mode 1 1 6 1 1 3 Enable Cipher 1021 IDs 1 1...

Page 48: ...6 1 0 Enable Tab Suffix The scanner will transmit a TAB ASCII 09H after each bar code 1 1 6 6 0 0 Disable Tab Suffix 1 1 6 6 1 4 Enable ETX Suffix The scanner will transmit End of TeXt ASCII 03H after the bar code date 1 1 6 6 0 4 Disable ETX Suffix 1 1 6 6 1 6 Enable UPC Suffix ID The scanner will transmit a suffix after any UPC EAN bar code The suffixes are A UPC A E UPC E F EAN 13 and F EAN 8 1...

Page 49: ...ed prior to adding parity bits When the LRC is enabled the scanner defaults to starting the LRC on the second byte of information transmitted Optionally the calculation can start on the first byte transmitted 1 0 7 8 1 1 Enable Transmit of LRC Calculation The scanner outputs on LRC check character after the bar code 1 0 7 8 0 1 Disable Transmit of LRC Calculation 1 0 7 8 0 0 Start LRC on First Byt...

Page 50: ... byte value of the character you wish to replace refer to the ASCII Reference Table in the Code Byte Usage section of this manual 4 Scan the replacement character bar code shown below 5 Scan the ASCII code byte value of the replacement character 6 Scan the enter exit configuration mode bar code on page 2 9 3 8 6 0 0 Character to Replace 9 3 8 7 0 0 Replacement Character 8 3 8 6 0 0 No Replacement ...

Page 51: ...third configurable suffix character 9 0 4 8 0 0 Configurable Suffix Character 4 Assigns a fourth configurable suffix character 9 0 4 9 0 0 Configurable Suffix Character 5 Assigns a fifth configurable suffix character 9 0 5 0 0 0 Configurable Suffix Character 6 Assigns a sixth configurable suffix character 9 0 5 1 0 0 Configurable Suffix Character 7 Assigns a seventh configurable suffix character 9...

Page 52: ... 1 6 7 0 1 Disable Newcode Formatting Mode A 1 1 6 7 1 0 Enable Newcode Formatting Mode B 1 1 6 7 0 0 Disable Newcode Formatting Mode B 1 0 8 0 1 7 Remove All Leading Zero s 1 0 8 0 0 7 Do Not Remove Leading Zero s 1 1 6 7 1 3 Enable MS951 CAPS Lock 1 1 6 7 0 3 Disable MS951 CAPS Lock 1 2 4 7 1 5 Enable HCA Parsing 1 2 4 7 0 5 Disable HCA Parsing ...

Page 53: ...and UPC E bar codes to the 12 digit equivalent UPC A bar codes 1 0 7 5 0 5 Do Not Expand UPC E to 12 Digits 1 0 7 6 0 2 Send Number System on Expanded UPC E 1 0 7 6 1 2 Do Not Send Number System on Expanded UPC E 1 0 7 5 1 0 Enable GTIN Formatting 1 0 7 5 0 0 Disable GTIN Formatting 1 0 7 5 1 4 Convert UPC A to EAN 13 The scanner converts UPC A to EAN 13 by transmitting a leading zero before the b...

Page 54: ...o EAN 13 1 0 7 5 0 2 Do Not Convert EAN 8 to EAN 13 1 0 7 5 1 1 Transmit UPC A Number System 1 0 7 5 0 1 Do Not Transmit UPC A Number System 1 0 7 6 1 1 Transmit UPC A MFR 1 0 7 6 0 1 Do Not Transmit UPC A MFR 1 0 7 6 1 0 Transmit UPC A ITEM 1 0 7 6 0 0 Do Not Transmit UPC A ITEM 1 0 7 9 1 0 Transmit EAN 8 Check Digit 1 0 7 9 0 0 Do Not Transmit EAN 8 Check Digit 1 0 7 9 1 2 Transmit EAN 13 Check ...

Page 55: ...ers as Lower Case Characters 1 0 7 7 1 6 Enable CLSI Editing Works only with 14 digit Codabar type lengths This option will perform CLSI type editing before the information is transmitted to the host 1 0 7 7 0 6 Do Not Enable CLSI Editing 1 0 0 4 1 0 Enable Codabar Mod 16 Check Digit 1 0 0 4 0 0 Disable Codabar Mod 16 Check Digit 1 0 0 4 1 1 Enable Codabar 7 Check Check Digit 1 0 0 4 0 1 Disable C...

Page 56: ... Code 39 s start and stop characters before and after each bar code 1 0 7 7 0 0 Do Not Transmit Code 39 Stop Start Characters 1 0 7 7 1 2 Transmit an A 41H Prefix if Italian Pharmaceutical 1 0 7 7 0 2 Do not Transmit an A 41H Prefix if Italian Pharmaceutical CODE 11 FORMATTING 1 0 7 7 1 3 Transmit Code 11 Check Digit This bar code will transmit Code 11 check characters when used with Enabled Code ...

Page 57: ...y Check Digit This option works in conjunction with one or both of the Enabled MSI Plessey Mod options on page 10 1 0 7 7 0 1 Do Not Transmit MSI Plessey Check Digit 2 OF 5 CODE FORMATTING 1 0 7 7 1 4 Transmit Mod 10 Check Digit on ITF The scanner transmits interleaved 2 of 5 ITF Mod 10 check character 1 0 7 7 0 4 Do Not Transmit Mod 10 Check Digit on ITF Works in conjunction with Mod 10 check on ...

Page 58: ...an odd number of bits are 1 s 3 1 6 0 1 5 Space Parity Select to set the parity bit always 0 3 1 6 0 2 5 Even Parity Select to set the parity bit to either a 1 or 0 to ensure an even number of bits are 1 s 3 1 6 0 3 5 Mark Parity Select Mark Parity to set the parity bit always 1 BAUD RATE 4 1 5 8 1 0 0 115200 BAUD Rate Not available with Voyager 4 1 5 8 9 0 57600 BAUD Rate Not available with Voyag...

Page 59: ...p Bit 1 1 6 0 0 4 2 Stop Bits HARDWARE HANDSHAKING 1 1 5 8 1 6 Enable RTS CTS Handshaking Output a Request to Send RTS signal and wait for a Clear to Send CTS signal before transmitting data 1 1 5 8 0 6 Disable RTS CTS Handshaking 1 1 5 8 1 5 Character RTS CTS Activates Deactivates RTS signal for each character 1 1 5 8 0 5 Message RTS CTS Activates RTS before sending the first character and leaves...

Page 60: ... for CTS Wait for CTS after activating RTS 1 2 4 5 1 3 Test CTS Not Present Before RTS RSV4 Do not activate RTS if CTS is already present 1 2 4 5 0 3 Do Not Test for CTS Present Before RTS 1 1 5 8 1 7 Enable DTR Support The scanner will stop scanning when the Data Terminal Ready DTR signal goes inactive 1 1 5 8 0 7 Disable DTR Support 1 1 5 9 1 5 Enable RTS Counter Toggle The scanner will toggle t...

Page 61: ...en the scanner will exit the communications loop silently 1 1 5 9 0 1 Ignore BEL CAN in ACK NAK Ignore BEL CAN characters in communication loop 1 1 8 0 1 3 Enable 5 Retries on ACK NAK Time Out Allow up to 5 NAK retransmissions of the data before dropping out of the communications loop 1 1 8 0 0 3 Disable 5 Retries on ACK NAK Time Out 1 1 5 8 1 4 Enable 5 NAK Retries Allow up to 5 retransmissions o...

Page 62: ...rm The scanner transmits PC type make break scan codes instead of ASCII data characters The scan codes match a WYSE French PC Term 1 1 6 1 0 0 Disable French PC Term 1 4 1 4 1 6 Enable NCR Scanner Only Commands 1 4 1 4 0 6 Disable NCR Scanner Only Commands ...

Page 63: ...scanner will send keyboard power on information and configure hardware to simulate a constant keyboard connection 5 1 5 5 1 4 3 Enable Keyboard Wedge Emulation Use this with an external keyboard Transmit in wedge made to allow standard PC keyboards to communicate when no bar code data is available COUNTRY SCAN CODE TABLE SELECTS 4 1 6 2 6 0 USA Keyboard 4 1 6 2 8 0 Switzerland Keyboard 4 1 6 2 5 0...

Page 64: ... KEYBOARD SYSTEM TYPE 2 1 6 2 1 5 AT Keyboard Includes IBM PS 2 and compatible models 50 55 60 80 2 1 6 2 0 5 XT Keyboard Special firmware in Voyager 2 1 6 2 2 5 PS 2 Keyboard Includes IBM PC and compatible models 30 70 8556 2 1 6 2 3 5 Enable Terminal Keyboard Emulation 1 1 6 3 0 7 Enable XT Keyboard for Mode 1 Special firmware in Voyager 1 1 6 3 1 7 Enable XT Keyboard for Mode 2 Special firmware...

Page 65: ...minal Keyboard 4 3 1 6 4 4 0 Reserved Terminal Keyboard 5 3 1 6 4 5 0 Reserved Terminal Keyboard 6 3 1 6 4 6 0 Reserved Terminal Keyboard 7 3 1 6 4 7 0 Reserved Terminal Keyboard 8 1 1 6 7 1 4 Lower Case Lock On transmit all data as lower case 1 1 6 7 0 4 Lower Case Lock Off 1 1 6 7 1 5 Spanish Keyboard Ñ Substitution the following two characters will translate as follows to Ñ and to ñ 1 1 6 7 0 5...

Page 66: ...le Alt Mode Caution If host software application uses the right Alt key as a Hot key Alt mode must be disabled These settings only apply if the Alt Mode shown above is enabled 1 1 6 7 0 6 Enable Alt Mode Normal The scanner will duplicate the following keyboard sequence Hold down the Alt key and Type the 3 digit decimal number that corresponds to the appropriate character 1 1 6 7 1 6 Enable Alt Mod...

Page 67: ...3 0 3 Use Extended ASCII To Send Extended Key Codes Use extended ASCII characters to send PC keyboard keys such as F1 F2 etc 1 1 6 3 1 3 Use Extended ASCII Characters as Extended ASCII Transmit extended ASCII codes via Alt Mode 1 1 6 3 0 4 Character KB Inhibit 1 1 6 3 1 4 Message KB Inhibit 1 1 6 3 0 2 Enable Right Alt Key Sequencing 1 1 6 3 1 2 Disable Right Alt Key Sequencing 1 1 6 4 1 3 Enable ...

Page 68: ...ween individual 11 bit scan codes This parameter may need to be adjusted for operation with certain PC keyboard BIOS 9 1 6 5 0 0 Variable InterScan Code Delay msec Refer to Multi Code Method on page 2 Sets value in 100 microsecond increments CONTROL SETS In general standard bar code symbologies will only encode the ASCII character set Function keys arrow keys and many other extended keys on an IBM...

Page 69: ...NQ Delete 06H ACK System Request 07H BEL Right Arrow 08H BS Left Arrow 09H TAB Tab 0AH LF Caps Lock 0BH VT Shift Tab 0CH FF Left Alt 0DH CR Enter 0EH SO Left Control OFH SI Up Arrow 10H DLE F1 11H DC1 F2 12H DC2 F3 13H DC3 F4 14H DC4 F5 15H NAK F6 16H SYN F7 17H ETB F8 18H CAN F9 19H EM F10 1AH SUB Home 1BH ESC Esc 1CH FS Page Up 1DH GS Page Down 1EH RS Print Screen 1FH US End ...

Page 70: ...al interface 9 9 9 9 9 3 Load OCIA Defaults 2 1 7 7 0 6 Enable DTS Siemens 2 1 7 7 1 6 Enable DTS Nixdorf 2 1 7 7 3 6 Enable NCR S 2 1 7 7 2 6 Enable NCR F 1 1 7 7 0 5 Transmit character count with non UPC codes while transmitting in OCIA NCR S mode 1 1 7 7 1 5 Do not Transmit character count with non UPC codes while transmitting in OCIA NCR S mode ...

Page 71: ...6 9 0 6 Transmit as Scanned All bar codes will be decoded and transmitted in that symbology 1 1 6 9 1 5 Poll Light Pen Source The scanner waits for an active source voltage before transmitting data 1 1 6 9 0 5 Do Not Poll Light Pen Source 1 1 6 9 1 1 Enable Inverted IDLE Extra Toggle The scanner beeps and toggles the light pen data line with an extra data pulse to condition the decoder 1 1 6 9 0 1...

Page 72: ...and emulation using a 50x border 8 1 6 8 1 6 3 0 1 ms Narrow Element Width Allows the transmission of Light Pen Wand emulation at 1ms Narrow Element width 8 1 6 8 1 0 0 60 µs Narrow Element Width 8 1 6 8 1 6 0 100 µs Narrow Element Width 8 1 6 8 8 2 0 500 µs Narrow Element Width 9 1 6 8 0 0 Variable Narrow Element Width Sets the minimum x dimension in 6 µs increments Scan this code followed by a 3...

Page 73: ...nable the Laser Emulation interface The scanner you are using must be labeled as an MS9520 00 or MS9540 00 to support this feature Enable HH Laser Emulation 9 9 9 9 7 9 If host controlled laser emulation is required scan the following bar code after scanning the Enable HH Laser Emulation bar code Enable Host Controlled Laser Emulation 1 1 7 0 1 0 1 1 7 0 0 1 Normal Laser Emulation Motor Idle State...

Page 74: ...ings for the IBM 46xx systems 3 1 7 2 5 0 IBM Port 17B 3687 2 In Counter 3 1 7 2 6 0 IBM Port 5B 1520 HH Laser 3 1 7 2 7 0 IBM Port 9B 4500 CCD HH BCR1 3 1 7 2 3 0 IBM Port 9B 4501 CCD HH BCR2 1 1 7 2 0 6 Disable CTS select of IBM 46xx vs RS232 1 1 7 2 1 6 Enable IBM 46xx transmit when CTS 12 Volt RS232 transmit when CTS 12 Volt IBM RESERVED CODES 3 1 7 2 0 0 IBM Reserved 1 3 1 7 2 1 0 IBM Reserve...

Page 75: ... Flatbed Full Speed USB Only 3 1 6 4 0 0 Enable USB Keyboard Emulation Mode 3 1 6 4 7 0 Enable Uni Directional USB Serial Emulation Mode Enables Uni Directional USB Serial Emulation Mode in Metrologic 9500 5100 4125 class products Enables Bi Directional USB Serial Emulation Mode in the Metrologic Focus Imager class products 3 1 6 4 6 0 Enable Bi Directional USB Serial Emulation Mode Enables Bi Dir...

Page 76: ... 9 9 9 7 3 Enable USB Reserve Code 2 9 9 9 9 7 2 Disable USB Reserve Code 2 9 9 9 9 6 7 Sears USB Defaults 9 9 9 9 6 6 Sears Aux Defaults 1 1 7 8 1 3 Enable IBM 1520 Code Flag Emulation UPC code ID and ITF code ID remain the same but all other code ID is transmitted as Code 39 IBM OEM Scanner Modes 1 1 7 8 0 3 Disable IBM 1520 Code Flag Emulation ...

Page 77: ...ing the 3 digit decimal equivalent of the ASCII character into the appropriate character location with the code byte bar codes To add an Asterisk as a Prefix scan the following bar codes in order 1 Enter Exit Configuration Mode 3 beeps 2 Configurable Prefix 1 1 beep 3 Code Byte 0 1 beep 4 Code Byte 4 2 beeps 5 Code Byte 2 3 beeps 6 Enter Exit Configuration Mode 3 beeps CODE BYTES 0 9 0 Code Byte 0...

Page 78: ... 7 Disable Reserved Code CODE TYPE TABLE Code Byte Code Types 004 UPC A 002 UPC E 003 EAN 8 005 EAN 13 080 Code 39 081 Codabar 082 Interleaved 2 of 5 083 Code 128 084 Code 93 091 MSI Plessey 092 Code 11 093 Airline 2 of 5 15 digits 094 Matrix 2 of 5 095 Telepen 096 UK Plessey 099 TRI OPTIC 098 Standard 2 of 5 097 Airline 13 digits ...

Page 79: ... 02 002 STX B 03 003 ETX C 04 004 EOT D 05 005 ENQ E 06 006 ACK F 07 007 BEL G 08 008 BS H 09 009 HT I 0A 010 LF J 0B 011 VT K 0C 012 FF L 0D 013 CR M 0E 014 SO N 0F 015 SI 0 10 016 DLE P 11 017 DC1 Q 12 018 DC2 R 13 019 DC3 S 14 020 DC4 T 15 021 NAK U 16 022 SYN V 17 023 ETB W 18 024 CAN X 19 025 EM Y 1A 026 SUB Z 1B 027 ESC 1C 028 FS ...

Page 80: ...1D 029 GS 1E 030 RS _ 1F 031 US space blank 20 032 SP 21 033 22 034 23 035 24 036 25 037 26 038 27 039 apostrophe 28 040 29 041 2A 042 2B 043 2C 044 comma 2D 045 minus 2E 046 period 2F 047 30 048 0 number zero 31 049 1 number one 32 050 2 33 051 3 34 052 4 35 053 5 36 054 6 37 055 7 38 056 8 39 057 9 3A 058 3B 059 ...

Page 81: ...qv 3C 060 less than 3D 061 3E 062 greater than 3F 063 40 064 shift P 41 065 A 42 066 B 43 067 C 44 068 D 45 069 E 46 070 F 47 071 G 48 072 H 49 073 I letter l 4A 074 J 4B 075 K 4C 076 L 4D 077 M 4E 078 N 4F 079 O letter O 50 080 P 51 081 Q 52 082 R 53 083 S 54 084 T 55 085 U 56 086 V 57 087 W 58 088 X 59 089 Y ...

Page 82: ...B 091 shift K 5C 092 shift L 5D 093 shift M 5E 094 à shift N 5F 095 _ shift 0 underscore 60 096 accent grave 61 097 a 62 098 b 63 099 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 I 6A 106 j 6B 107 k 6C 108 l 6D 109 m 6E 110 n 6F 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x ...

Page 83: ...9 74H 4DH 6AH 82H 130 6BH 4BH 61H 83H 131 Insert 70H 52H 67H 84H 132 Delete 71H 53H 64H 85H 133 Home 6CH 47H 6EH 86H 134 End 69H 4FH 00H 87H 135 Page Up 7DH 49H 00H 88H 136 Page Down 7AH 51H 00H 89H 137 Right Alt 11H 38H 00H 8AH 138 Right Ctrl 14H 1DH 39H 8BH 139 Reserved 00H 00H 00H 8CH 140 Reserved 00H 00H 00H 8DH 141 Numeric Keypad Enter 5AH 1CH 79H 8EH 142 Numeric Keypad 4AH 35H 00H 8FH 143 F1...

Page 84: ...2H 2AH 12H A3H 163 Right Shift 59H 36H 59H A4H 164 Print Screen Multiple 00H 00H A5H 165 Tab ODH OFH 0DH A6H 166 Shift Tab 8DH 8FH 65H A7H 167 Enter 5AH 1CH 5AH A8H 168 ESC 76H 01H 08H A9H 169 Left ALT Make 11H 36H 00H AAH 170 Left ALT Break 11H B6H 00H ABH 171 Left CTRL Make 14H 1DH 00H ACH 172 Left CTRL Break 14H 9DH 00H ADH 173 Left ALT 1 character 11H 36H 00H AEH 174 Left Crtl 1 character 14H ...

Page 85: ...Range Out of Stand STAND SCAN MODES 1 2 0 1 1 7 Short Scan In Stand while scanning in the stand the unit will only accept bar codes within the short IR range 1 2 0 1 0 7 Normal Scan In Stand CODEGATE STATUS Use the following bar codes to control button functions Note The following functions are not supported by all versions of the MS5145 1 1 8 7 0 7 CodeGate Active in Stand 1 1 8 7 1 7 CodeGate In...

Page 86: ...ature is not available for the VoyagerPDF series 4 1 8 3 4 4 Custom One Shot Scan The laser turns off after a good decode 4 1 8 3 5 4 Enable Manual Activation Mode The laser activates when the CodeGate button is pressed 1 2 0 0 0 0 Normal Timeout Button Act 1 2 0 0 1 0 0 5 Second Timeout Button Act Note MS9520 models from Rev H and beyond will be equipped with limited PDF scan decode capability Pl...

Page 87: ...o Same Symbol Time Out 8 1 8 9 1 0 1000 msec Same Symbol Time Out 8 1 8 9 2 0 875 msec Same Symbol Time Out 8 1 8 9 3 0 750 msec Same Symbol Time Out 8 1 8 9 4 0 625 msec Same Symbol Time Out 8 1 8 9 5 0 500 msec Same Symbol Time Out 8 1 8 9 6 0 375 msec Same Symbol Time Out 8 1 8 9 7 0 250 msec Same Symbol Time Out 1 1 8 9 1 7 Infinite Same Symbol Time Out ...

Page 88: ...DF CODEGATE STATUS 1 1 8 7 1 6 Enable PDF CodeGate in Stand 1 1 8 7 0 6 Disable PDF CodeGate in Stand 1 1 8 7 1 4 Enable PDF CodeGate Out of Stand 1 1 8 7 0 4 Disable PDF CodeGate Out of Stand MICROPDF AND COMPOSITE CODE HANDLING 1 0 0 4 1 7 Enable MicroPDF Allows composite symbologies to be scanned PDF 417 is enabled by default 1 0 0 4 0 7 Disable MicroPDF ...

Page 89: ... Linkage Transmit the 2D portion of the PDF 417 w o scanning the 1D portion 1 1 5 0 1 4 Disable PDF 1D Linkage 1 1 5 0 0 3 Enable UPDF 1D Linkage Transmit the 2D portion of microPDF w o scanning the 1D portion 1 1 5 0 1 3 Disable UPDF 1D Linkage 1 1 5 0 0 2 Normal Composite Xmit Always transmit the 1D and 2D constituent composite components separately 1 1 5 0 1 2 Xmit Composite Separately Transmit...

Page 90: ...s try to initiate a communication connection 1 2 4 3 0 6 Bluetooth Pin Not Required 8 4 0 9 0 0 Bluetooth PIN Default Value the default PIN ID will be the last 4 digits of the serial number 9 9 9 9 1 8 Next Bar Code is Bluetooth Pin when scanned this feature enables the scanner to store the next scanned bar code as the Bluetooth PIN ID The Bluetooth PIN ID must be numeric and be 4 to 16 characters...

Page 91: ...le indicator the when Bluetooth scanner is in the stand charging cradle but is not making contact via the battery terminal contacts 1 2 3 7 0 1 Disable In Stand Error Indicator 1 2 3 7 0 2 Enable Cradle LED 1 2 3 7 1 2 Disable Cradle LED 1 2 3 7 0 7 Enable Range Gate Store scanned barcodes into RAM if the Bluetooth connection has been interrupted 1 2 3 7 1 7 Disable Range Gate 1 2 3 7 1 6 Enable B...

Page 92: ...s placed into the Bluetooth cradle 1 2 3 9 1 3 No Cradle Transmit The scanner will not automatically transmit bar code data when placed in the Bluetooth cradle 1 2 3 9 0 1 Transmit Inventory FIFO Data is transmitted on a first in first out basis 1 2 3 9 1 1 Transmit Inventory LIFO Data is transmitted on a last in first out basis 1 2 3 9 1 2 Enable Inventory Beep A beep will sound as each bar code ...

Page 93: ...If a quantity of 103 Quantity 1 Quantity 0 and Quantity 3 was scanned but a quantity of 10 was desired 1 Scan the delete last record bar code 2 The Quantity 3 code will be deleted and a quantity of 10 will be stored 9 9 8 0 5 0 Transmit All Records Transmits all stored data records 9 9 8 0 5 1 Transmit Record Counters Will transmit the number of records and the number of bar codes currently stored...

Page 94: ...transmitted as many times as the quantity indicates Example 1 Scan the item s bar code ie ABCD 2 Scan the Quantity 1 bar code 3 Scan the Quantity 0 bar code 4 The ABCD bar code will be transmitted 10 times Q 0 Quantity 0 Q 1 Quantity 1 Q 2 Quantity 2 Q 3 Quantity 3 Q 4 Quantity 4 Q 5 Quantity 5 Q 6 Quantity 6 Q 7 Quantity 7 Q 8 Quantity 8 Q 9 Quantity 9 Transmit Quantity Field must be enabled on p...

Page 95: ... 1 1 Enable TTL UART 1 2 0 3 1 2 Enable Non Buffered TTL UART 1 2 0 3 1 3 Enable Detect and Notify Mode 8 4 6 6 0 1 1 0 Cunningham Defaults Scan this code followed by Recall Defaults code to enable and load Cunningham defaults 9 9 9 9 9 8 Recall Defaults For Same Symbol Time Out information please refer to page 80 ...

Page 96: ...o enable and load Ruby Verifone defaults 8 4 6 6 0 0 1 0 RCH Scan this code followed by Recall Defaults code to enable and load RCH defaults 8 4 6 6 0 0 2 0 Sanyo Scan this code followed by Recall Defaults code to enable and load Sanyo defaults 8 4 6 6 0 0 3 0 Gilbarco Scan this code followed by Recall Defaults code to enable and load Gilbarco defaults 8 4 6 6 0 0 4 0 ALT Defaults Scan this code f...

Page 97: ...nsmit STX 999998 ETX through the Serial Port This is the Recall Defaults bar code in the MetroSelect guide The scanner will respond with an ACK 06 Hex 3 Transmit STX 999999 ETX through the Serial Port This will cause the scanner to exit program mode and save the new settings The scanner will beep 3 times and send an ACK 06 Hex If at anytime the scanner cannot recognize a command it will respond wi...

Page 98: ......

Page 99: ......

Page 100: ......

Page 101: ...April 2007 Version 01 Printed in the USA 0 0 0 2 5 4 4 H ...

Reviews: