7.2.
Mounting The Plastic-Housing Instrument
The plastic-housing MeshGuard LEL IR or MeshGuard CO2 IR is permanently mounted to a solid surface
by first securing it in its steel enclosure (a screw through the back mates with the instrument) and then
securing the enclosure to a solid surface such as a wall or the metal mounting plate.
Front, side, and rear views of the steel enclosure show how the instrument is secured for
mounting.
7.2.1.
Replacing The Internal Battery
With the MeshGuard LEL IR or MeshGuard CO2 IR securely in its housing, you can remove the
cover over the battery compartment so that you can replace the internal battery in the instrument.
Use the sensor and battery removal tool as shown.
WARNING:
Use only RAE Systems battery P/N 500-0111-000 (EVE ER34615 or XENO XL-205F)
for the internal battery. The internal battery must be replaced under a Hot Work Permit, where the
atmosphere is determined to be non-hazardous while the battery is being replaced.
M4x10 Screw in
rear of enclosure
mates to rear of
MeshGuard LEL IR
or Meshguard CO2
IR
Use M5-size screw
(or nut) with flat
washer and lock
washer to secure
enclosure at all
four corners
Sensor and battery
removal tool
(P/N 019-2044-000)