This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation.

 

 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 
Part 15 of the FCC rules.  These limits are designed to provide reasonable protection against harmful 
interference in a residential installation.  This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to 
radio communications.  However, there is no guarantee that interference will not occur in a particular 
installation.  If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by 
one or more of the following measures: 
 

  Reorient or relocate the receiving antenna 

  Increase the separation between the equipment and receiver 

  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 

  Consult the dealer or an experienced radio/TV technician for help 

 

Notice

 

This Class B digital apparatus complies with Canadian ICES-003. 
 

Avertissement 

Cet appareil numérique de la class B est conforme à la norme NMB-003. 
 

Summary of Contents for IS220

Page 1: ...IS220 OEM Scan Engine User s Guide ...

Page 2: ...riety information that is protected by copyright All rights reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII 2004 2011 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Trademarks Metrologic MetroSelect MetroSet2 are trademarks or registered trademarks of Metrologic Instrumen...

Page 3: ...nostic Indicator Display 7 Depth of Field 9 Troubleshooting Guide 11 Design Specifications Operational 15 Mechanical 15 Electrical 15 Environmental 16 Upgrading the Flash ROM Firmware 17 Default Settings Communication Parameters 19 Scanner and Cable Terminations Scanner Pinout Connections 25 Cable Connector Configurations 25 Limited Warranty 27 Laser and Product Safety Cautions 29 Notices 30 Index...

Page 4: ...iii Customer Support Technical Assistance 33 Product Service and Repair 34 ...

Page 5: ...232 00 02029 IS220 Installation and User s Guide 00 02407 MetroSelect Guides also available for download at www honeywelladic com Configuration Guide Optional Accessories Part Number Description 52 52548 Communication Power Cable 110 Volt 52 52547 Communication Power Cable 220 Volt Other items may be ordered for the specific protocol being used To order additional items contact the dealer distribu...

Page 6: ...tal or vertical output windows require cleaning use only a mild glass cleaner containing no ammonia When cleaning the window spray the cleaner onto a lint free non abrasive cleaning cloth then gently wipe the window clean If the unit s case requires cleaning use a mild cleaning agent that does not contain strong oxidizing chemicals Strong cleaning agents may discolor or damage the unit s exterior ...

Page 7: ... Description Hardened Glass Window Laser Aperture Black Metal Housing 15 pin Male D Sub Connector for Communication Power Cable Connection Two PEM B M5 2 Mounting Holes Provided Red and Green LED Diagnostic Indicator Display Two Digit Error Code Display ...

Page 8: ...4 Labels Figure 3 Label Locations and Examples ...

Page 9: ... ROM upgrade is needed the scanner will beep twice followed by alternating flashes of the red and green LEDs Three Beeps During Operation When the scan engine enters configuration mode the red LED will flash and the unit will simultaneously beep three times The green and red LEDs will continue to flash while in configuration mode Upon exiting configuration mode the scanner will beep three times an...

Page 10: ...s experienced a laser subsystem failure The scanner will try up to 3 times to correct the failure condition If the laser subsystem continues to fail that subsystem left or right will be shut down and an error indication will be shown on the Diagnostic Indicator Display This error stays on the display until corrected If the remaining subsystem is still operational scanning will continue using the o...

Page 11: ...empts are made to enter MetroSet configuration mode A short on the RX Data line can cause this condition It can also be the result of a laptop in power save mode The scanner will abort attempts to enter configuration mode after a short timeout The scanner can automatically recover from this condition once the short in the RX Data line is corrected 21 LASER 1 left ERROR The laser in the left scanni...

Page 12: ...emain active and scanning until the unit can be scheduled for repair at an authorized service center 32 MOTOR 2 right ERROR The motor in the right scanning subsystem denotes a failure The scanner will try three times to correct the motor operation If the motor error persists the right scanning subsystem will be shut down and error code 32 will remain on the diagnostic indicator display If the left...

Page 13: ...9 Depth of Field Figure 6 Depth of Field Specifications subject to change without notice ...

Page 14: ...10 ...

Page 15: ...times on power up There has been a Non volatile RAM failure Contact a service representative if the unit will not hold the programmed configuration The unit razzes continuously on power up There has been a diagnostic failure Contact a service representative if the unit will not function At power up there is a Razz tone and the green LED flashes There has been a VLD failure Contact a service repres...

Page 16: ...nfigured to support some form of host handshaking but is not receiving the signal If the scanner is setup to support ACK NAK RTS CTS XON XOFF or D E verify that the host cable and host are supporting the handshaking properly The unit scans but the data transmitted to the host is incorrect The scanner s data format does not match the host system requirements Verify that the scanner s data format ma...

Page 17: ...e computer is in Caps Lock mode Enable the Caps Lock detect setting of the scanner to detect whether the PC is operating in Caps Lock Power up OK and scans OK but does not communicate properly to the host Com port at the host is not working or configured properly Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for RS 232 d...

Page 18: ...14 ...

Page 19: ...ontrast 35 minimum reflectance difference Number of Characters Read Up to 80 data characters The maximum number will vary based on symbology and density Audible Indicators Internal beeper Visual Indicators Default Settings Green LED Laser on ready to scan Red LED Good read decoding Mechanical Length 295 mm Width 150 mm Depth 75 mm Weight 2 5 Kg maximum excluding cable Termination 15 pin Male D sub...

Page 20: ...to 40 C 32 F to 104 F Storage 40 C to 60 C 40 F to 140 F Humidity 5 to 95 relative humidity non condensing Contaminants Sealed to resist airborne particulate contaminants Ventilation None required Specifications subject to change without notice ...

Page 21: ...e 3 Click on the plus sign next to Industrial Scanners to expand the supported scanner list 4 Choose the IS220 from the list 5 Click on the Configure IS220 Scanner button 6 Choose Utility Flash Main Processor from the options list located on the left side of the screen 7 Click on the Open File button in the Flash Utility window 8 Locate and open the flash upgrade file 9 Select the COM port that th...

Page 22: ...18 ...

Page 23: ...e interface supports a parameter listed in the charts on the following pages a check mark will appear Parameter Default RS232 UPC EAN Code 128 Code 93 Codabar Interleaved 2 of 5 ITF MOD 10 Check on ITF Code 11 Code 39 Full ASCII Code 39 MOD 43 CD on Code 39 Transmit Mode 43 CD Paraff Paraff Lead A Allow Paraff Failures French PC Terminal MSI Plessey Airline 15 digit 2 of 5 Airline 13 digit 2 of 5 ...

Page 24: ...eep Beep Twice on Supplements No Beeps on Timeout 5 Retries Before Timeout Timeout In 2 secs Laser Off Between Records Variable Laser Off Delay 5 635 msec Flash LED on Good Scan Reverse LED Convention Flash LED on Good Scan Enter Power Save Mode 10 mins Blink Power Save Mode Laser OFF Power Save Mode Laser Motor OFF Power Save Mode Dual Action Power Save Mode 1 Dual Action Power Save Mode 2 Same S...

Page 25: ...p Characters Codabar CLSI Dual Field Codabar Tab Between Dual field Codabar Codabar CLSI Check Digit Codabar 7 Check Check Digit Codabar Mod 16 Check Digit Transmit MSI Plessey Check Digits Number of MSI Plessey Check Digits 0 UK Plessey A to X Convert UK Plessey Special 12 Character Format Transmit UK Plessey Check Digit EAN 128 Enable Enable French Pharma Enable Matrix 2 of 5 Check Digit Enable ...

Page 26: ...aracter Xmit No Read Message on DC2 Timeout No Transmit LED During No Read Message Programmable No Read Message Recv I Transmit METROLOGIC Recv i Transmit Scanner ID Byte STX Prefix TAB Prefix Metrologic Prefix UPC Prefix ETX Suffix TAB Suffix Carriage Return Suffix Line Feed Suffix UPC Suffix Transmit LRC Start LRC on 1st Byte Start LRC on 2nd Byte c Prefix for UPC Prefix for UPC Programmable Pre...

Page 27: ...nts Five Digit Supplements Require Supplements Remote Supplement Support Two Digit Redundancy Five Digit Redundancy Enable Coupon Code 128 Transmit Coupon C1 Group Separator Coupon Code Can Begin with 4 Enable EAN 99 Coupon Code Bookland Convert Bookland to ISBN Reformat ISBN Transmit ISBN Check Digit Bookland 977 2 Digit Supp Required 378 379 Supplements 414 419 Supplements 434 439 Supplements Nu...

Page 28: ...24 ...

Page 29: ... 5V 11 5V 12 GND 13 GND 14 Earth Ground 15 External Beeper Cable Connector Configurations 52 52548 and 52 52547 Communication Power Cable Standard 15 pin Female D Sub Standard 9 pin Female D Sub Pin Function Pin Function 1 Shield GND 1 N C 2 TXD 2 TXD 3 RXD 3 RXD 4 DTR 4 DTR 5 GND 5 GND 6 DSR 6 DSR 7 CTS 7 CTS 8 RTS 8 RTS 9 N C 9 N C 10 5V 11 5V 12 GND 13 GND 14 Lug 15 N C ...

Page 30: ...26 ...

Page 31: ...I EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT HII S RESPONSIBILITY AND PURCHASER S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR ...

Page 32: ...28 ...

Page 33: ...ardez jamais directement le rayon laser même si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous exposez à une rayonnement laser qú êst hazardous L emploi d appareils optiques avec cet équipement laser augmente le risque d endommagement de la vision Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen Einstellunge...

Page 34: ...nce with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the foll...

Page 35: ... Settings 19 23 Depth of Field Far 10 Near 10 Diagnostic Indicator Display 3 7 E EMC 15 Error Codes 3 7 F Failure Modes 5 FCC 29 Flash ROM Firmware 17 G Green LED 3 5 Ground 25 H Host 19 23 I Indicators Audible 5 11 13 19 23 Error Codes 3 7 Failure 3 5 Visual 3 5 11 13 19 23 L Label Caution 4 Location 4 Serial Number 4 Laser Aperture 3 10 Laser Class 15 Laser Light 4 7 29 M Maintenance 7 10 Meteor...

Page 36: ...ns Electrical 15 Environmental 15 Mechanical 15 Operational 15 Symbol Length 11 13 T Troubleshooting 11 13 U Upgrade 17 V Visual Indicator Green LED 3 5 11 13 19 23 Red LED 3 5 11 13 19 23 W warranty 27 Window 3 7 10 ...

Page 37: ...co Telephone 01 800 HONEYWELL 01 800 466 3993 E mail soporte hsm honeywell com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail hsmeurosupport honeywell com Hong Kong Telephone 852 29536436 Fax 851 2511 3557 E mail aptechsupport honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail aptechsupport honeywell com China Telephone 86 800 828 2803 Fax ...

Page 38: ... 55 21 3535 9105 E mail brservice honeywell com Mexico Telephone 01 800 HONEYWELL 01 800 466 3993 Fax 52 55 5531 3672 E mail mxservice honeywell com Europe Middle East and Africa Telephone 31 0 40 2901 633 Fax 31 0 40 2901 631 E mail euroservice honeywell com Hong Kong Telephone 852 29536436 Fax 851 2511 3557 E mail apservice honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail a...

Page 39: ......

Page 40: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 00 02029 Rev C 5 11 ...