END-OF-SEASON CARE AND STORAGE

When the humidifier will not be used for at least one week, or it is the end of the season, fol-

low the 

WEEKLY CARE AND CLEANING

 instructions in this manual.

If it is the end of the season, remove and discard any accessories from the humidifier. 
Dry the humidifier completely before storing. 

Do not 

store with water inside the Base, Heating 

Chamber or Water Tank.
Pack unit in original carton and store in a cool, dry location.

REASSEMBLE HUMIDIFIER

1. 

Place Removable Tray over heating element. Push Locking Tab toward back of unit so Removable 

Tray Lift Tab locks in place.

2. 

Align Cooling Chamber Tab over Removable Tray. Push Locking Tab toward back of unit so 

Cooling Chamber Tab locks into place beside Removable Tray Tab.

3. 

Replace Water Tank on Base.

4. 

Humidifier is ready to use. See Operating Instructions. 

WEEKLY CARE AND CLEANING 

(Continued from previous page)

TROUBLESHOOTING

Solution

•   Plug unit in
•   Check circuits, fuses, test outlet

•   Fill Water Tank
•   Place on a level surface
•   Follow Cleaning Instructions  

on previous pages

•   Rinse thoroughly with  

clean water 

•   Refill Water Tank
•   Follow Reset Procedure

•  Check Water Tank for leaks; contact 

Consumer Relations if necessary

•   Tighten Tank Cap

•   Decrease mist output to low 

setting and/or open door to  

the room

If your Humidifier is not working properly, refer to the following:

Problem

•   Power Knob is set to “On” 

and green light around  

Power Knob is off

•   Little or no mist is produced

•   Reset Light illuminated

•   Water  overflows 

from Reservoir

•   Condensation forms around 

humidifier or on windows

Possible Cause

•   Unit not plugged in
•   No power at outlet

•   No water in Water Tank
•   Unit is not level
•   Mineral deposits on Heating 

Element or Removable Tray

•   Water Tank was washed 

with detergent

•   Water Tank is empty
•   Unit not reset after refill

•   Water Tank may be leaking 

•  Tank Cap is not tight

•   Mist intensity is set too 

high for room size or  

pre-existing humidity level

NOTE:

 Failure to keep this unit clean from mineral deposits normally contained in any water 

supply will affect the efficiency of operation of this unit. Customer failure to follow these 
instructions may void the warranty.

Instructions for Scale Removal (continued)

5.

 Fill Heating Chamber with 1 cup undiluted white vinegar. Vinegar should completely cover  

Heating Element. 
Place Removable Tray over Heating Element. Push Locking Tab towards back of the unit so  

Removable Tray Tab locks in place.
Vinegar solution will loosen mineral buildup (scale) on Heating Element and bottom of Cooling  

Chamber as they soak.

6.

 Soak Heating Element in vinegar solution for 15-20 minutes then gently scrub with a soft 

brush to remove mineral deposits. 

Do not

 use hard brushes, steel wool or other hard abrasives 

on the heating element. Doing so will damage the heating element.
Rinse Base and Removable Tray with water until smell of vinegar is gone.

 

CAUTION: Do not

 immerse base in water. 

7. 

Wipe Cooling Chamber, Medicine Cup and Removable Tray with a little vinegar and clean cloth  

if not already cleaned in dishwasher.

 Step 7

 Step 6

 Step 5

Instructions for Disinfecting

Follow Steps 1-4 in Scale Removal Instructions in previous section.

For Step 5: While humidifier is disassembled, add 1 tsp of bleach to 1 gallon (3.8L) of water 

and fill Water Tank with this solution. Replace Tank Cap. Swish solution around in Water Tank. 
If not cleaning Removable Tray, Mist Chimney and Medicine Cup in dishwasher, use some of 

the bleach solution to wipe these components clean. 
Empty tank and rinse all components with water until smell of bleach is gone.

NOTE: 

Using more than 1 tsp of bleach per gallon (3.8L) of water may result in damage to  

your humidifier. 
See steps 6-7 in Scale Removal Instructions in previous section to complete Disinfecting process.

NOTE:

 

Do not 

mix vinegar and bleach solutions together. Scale Removal and Disinfecting must 

be done separately.

 Step 5

Summary of Contents for HWM705 Series

Page 1: ... shock hazard plug the appliance directly into a 120V AC electrical outlet 6 The appliance should always be unplugged and emptied when not in operation or while being cleaned Shut off and unplug humidifier before moving Do not move or tilt humidifier while it is in operation Plug and unplug unit with dry hands Never pull by cord 7 Do not operate the appliance without water Turn off and unplug unit...

Page 2: ...or through Kaz com Kaz Inhalant KFC 4 in U S or Vicks VapoSteam VS177CANEA in Canada Can be added to medicine cup area to provide soothing menthol vapors to help provide comfort Protec Cleaning Cartridge PC 1BXN in U S or PC 1C in Canada Keeps your humidifier cleaner longer Continuously cleans and protects humidifiers against bacteria and mold for 30 days 1 Remove humidifier and all contents from ...

Page 3: ...the humidifier turned off unplugged and cooled for at least 20 30 min gently wipe residue from Medicine Cup 3 Do not add liquid inhalants or any additives other than those recommended by the manufacturer and do not add liquid inhalants or any additives directly to the water Doing so can have adverse effects on the humidifier Step 2 Step 1 Liquid Inhalant Step 3 To properly clean your humidifier we...

Page 4: ...k Cap is not tight Mist intensity is set too high for room size or pre existing humidity level NOTE Failure to keep this unit clean from mineral deposits normally contained in any water supply will affect the efficiency of operation of this unit Customer failure to follow these instructions may void the warranty Instructions for Scale Removal continued 5 Fill Heating Chamber with 1 cup undiluted w...

Page 5: ...ruction manual D Return defective product to Kaz USA Inc with a brief description of the problem Include proof of purchase and a 10 US 15 50 CAN check or money order for handling return packing and shipping charges Please include your name address and a daytime phone number You must prepay shipping charges We suggest having tracking or delivery confirmation Send to In U S A Helen of Troy Attn Retu...

Page 6: ...ons fournies 10 Ne pas employer cet appareil au grand air il est uniquement conçu pour servir à l intérieur 11 Ne pas couvrir ou insérer quoi que ce soit dans les orifices de l appareil 12 Ne pas essayer de réparer ou d ajuster toute fonction électrique ou mécanique de l appareil sous peine d annulation de la garantie 13 Ne mettre aucun produit médicamenteux inhalant Kaz ou Vicks VapoSteamMD par e...

Page 7: ...ion d ARRÊT brancher l appareil plein sur une prise polarisée de courant alternatif de 120 volts Ne pas forcer la fiche dans la prise elle n enfonce que dans un sens Pour éviter tout choc électrique ne pas brancher l humidificateur avec les mains mouillées 2 Débit mettre le bouton d alimentation au réglage haut ou bas afin de sélectionner le niveau d humidité voulu Le voyant vert du bouton d alime...

Page 8: ...ons de détartrage suite 5 Verser 250 mL 1 tasse de vinaigre blanc non dilué dans la chambre de refroidissement Le vinaigre devrait complètement recouvrir l élément chauffant Placer le plateau amovible sur l élément chauffant Pousser la patte de blocage vers l arrière de l appareil de façon à ce que le plateau amovible se verrouille en place En le trempant le vinaigre désagrégera le tartre incrusta...

Page 9: ...us en cas d anomalie de fonctionnement Problème Le bouton d alimentation est réglé à marche O mais son voyant vert est éteint Dégagement de peu ou pas de vapeur Voyant de réinitialisation allumé De l eau déborde du réservoir Condensation se formant autour de l humidificateur ou sur les fenêtres Cause possible Appareil non branché Prise non alimentée Réservoir vide Appareil instable Élément chauffa...

Page 10: ...carcasa inferior y el Tanque de Agua no están unidos 16 Sólo Para Uso Residencial La Marca Registrada Honeywell es utilizada por Kaz USA Inc bajo licencia de Honeywell International Inc Honeywell International Inc no hace ninguna declaración o garantía con respecto a este producto GARANTIE LIMITÉE DE 3 ANS Prière de lire toutes les instructions avant de tenter d utiliser ce produit A Cette garanti...

Page 11: ...a fría No llene con agua tibia o caliente 3 Vuelva a colocar la Tapa del Tanque girándola hacia la derecha para cerrar No apriete de más Coloque el Tanque de Agua de vuelta en la Base del humidificador y encienda el humidificador Paso 1 Paso 2 Paso 3 INSTALAR SU HUMIDIFICADOR LLENAR RELLENAR NOTA El Tanque de Agua debe transportarse con las dos manos una mano sujetando el Asa Superior del Tanque y...

Page 12: ...e Medicina después de su uso Con el humidificador apagado desconectado y frío por al menos 20 30 minutos limpie suavemente el residuo en el Dosificador de Medicina 3 No agregue inhalantes líquidos o ningún aditivo que no sean los recomendados por el fabricante y no agregue inhalantes líquidos o ningún aditivo directamente en el agua Hacerlo Paso 2 Paso 1 Inhalantes Líquido Paso 3 Para limpiar adec...

Page 13: ...de tener fugas Tapa del Tanque no está apretada La intensidad del vapor está demasiado alta para el tamaño de la habitación o para el nivel de humedad existente NOTA El no mantener esta unidad limpia de los depósitos minerales normalmente contenidos en cualquier fuente de agua afectará la eficiencia de operación de esta unidad El incumplimiento del cliente en seguir estas instrucciones podría anul...

Page 14: ...A Inc con una breve descripción del problema Incluya la prueba de compra junto con un cheque o giro postal por 10 US 15 50 CAN para cubrir gastos de administración regreso de empaque y envío Por favor incluya su nombre dirección y un número de teléfono para comunicarse durante el día Los gastos de envío deben pagarse por adelantado Le sugerimos que solicite confirmación del seguimiento o de la ent...

Page 15: ...28 ...

Reviews: