Maintenance
User manual for HON R100 gas pressure regulator with HON P095NG pilot
62
8.5
Maintaining the pilot
Topic
Page
Maintaining the HON P095NG‐HP pilot
62
Maintaining the HON P095NG‐MP pilot
65
Maintaining the P095 pilot’s adjustable restrictor
75
8.5.1
Maintaining the HON P095NG‐HP pilot
Crush and impact hazard posed by components falling or toppling over accidentally.
When working with heavy components that have been removed or are yet to be installed,
injury may result if the components start moving in an uncontrolled manner, e.g., fall
down
from the working surface or topple over.
Place removed components exclusively on level, horizontal working surfaces with enough
load‐bearing capacity.
If necessary, secure removed components so that they will not fall or topple over.
Wear the required personal protective equipment.
Exercise caution when performing the relevant tasks.
Observe the following cleaning instructions:
Before assembly, all parts must be cleaned in order to remove any foreign particles
(swarf) and soiling.
If screws, bolts, or washers are replaced with identical new parts, any oil on these new
parts must first be removed.
Observe the tightening torques below when following the instructions in this section:
Part
Tightening torque
Step
Screws
47
Nm
42
Proceed as follows:
Figure
Step
Description
1‐33
As indicated in Maintaining the
HON
P095NG‐HP pilot.
34
Take the diaphragm unit for the second
pressure stage. Unscrew the upper dia‐
phragm plate (1) and the hex nut (2) from
the pin (3).
Contents
Falling components
Cleaning
Tightening torques
Maintaining the
HON
P095NG‐HP pilot