APPLICATION

The H8908B Humidistat and H8908C Dehumidistat 
(humidity controllers) provide automatic low voltage 
control of humidifiers and dehumidifiers or ventilators, 
respectively, in central heating and air conditioning 
systems. They have a spst, snap-acting, dust-proof 
switch and are designed for wall or surface duct 
mounting.

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow 
them could damage the product or cause a hazard-
ous condition.

2.

Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 
your application.

3.

Installer must be a trained, experienced service 
technician.

4.

After installation is complete, check out product 
operation as provided in these instructions.

CAUTION

Personal Injury Hazard.
Power supply can cause electrical shock.

Disconnect power supply before beginning 
installation. 

Location and Mounting

The styling of the H8908 is designed to blend with the 
latest T8600 family of Honeywell Chronotherm® IV 
Deluxe Programmable Thermostats. A mounting 
template is included for mounting the H8908 next to the 
T8600. The H8908 can also be mounted at any other 
convenient location in the living area or equipment room. 
See Fig 1.

NOTE: The H8908 electrical connections are not 

shared with the thermostat.

Fig. 1. H8908B Humidistat.

Wall Mounting

IMPORTANT

Mount the control in an area with average room 
temperature and average relative humidity.

The following mounting instructions are for mounting the 
H8908 on the wall next to the T8600. When installing the 
H8908 at another location, modify the procedure to fit the 
installation.

1.

Hold the mounting template (included) next to the 
T8600. Select the mounting side for the H8908. 
The template is reversible for mounting on either 
the left or right side of the T8600. See Fig. 2.

2.

Mark the holes for the two mounting screws 
(included). Then mark the hole for the low voltage 
wiring on the template that corresponds with the 
side selected in step 1. 

3.

Remove the template and drill the holes.

4.

Run low voltage wiring to the location and pull 
about 6 in. (152 mm) of wire through the hole.

5.

Plug the hole with nonflammable insulation to pre-
vent drafts from affecting the control operation.

6.

Remove the H8908 case from the base. See 
Fig. 1.

7.

Position the base on the wall with the arrow up.

Humidity Control

Régulateur d'humidité

-20 

°

F

-10 

°

F

°

F

+10 

°

F

+20 

°

F

Over 20 

°

F

15%

20%

25%

30%

35%

40%

HUMIDITY
SETTING

OUTDOOR

TEMPERATURE

-30 

°

C

-25 

°

C

-20 

°

C

-10 

°

C

-5 

°

C

Over 0 

°

C

M13371

CASE REMOVAL 
SLOT

HOLE FOR WIRING 
THE DUCT MOUNTING 
INSTALLATIONS

Summary of Contents for H8908B Humidistat

Page 1: ...ext to the T8600 The H8908 can also be mounted at any other convenient location in the living area or equipment room See Fig 1 NOTE The H8908 electrical connections are not shared with the thermostat Fig 1 H8908B Humidistat Wall Mounting IMPORTANT Mount the control in an area with average room temperature and average relative humidity The following mounting instructions are for mounting the H8908 ...

Page 2: ...lace the H8908 case IMPORTANT Use 18 to 22 gauge wire for proper wiring Fig 4 Positioning return air duct template M13370 THERMOSTAT WALLPLATE MOUNTING TEMPLATE MOUNTING HOLES 2 WIRING HOLES FOR MOUNTING ON RIGHT USE LEFT HOLES FOR MOUNTING ON LEFT ALTERNATE LOCATION RETURN AIR RETURN AIR 6 in 152 mm MINIMUM 15 in 381 mm MINIMUM BEST LOCATION RETURN AIR DUCT M13369 CAUTION Equipment Damage Hazard ...

Page 3: ...rols Fig 5 Typical wiring diagram for system with fan interlock Fig 6 Typical wiring diagram for system with 2 speed fan motor Fig 7 Typical wiring diagram of current sensing relay with humidifier Fig 8 Typical wiring diagram of sail switch with humidifier Fig 9 Typical wiring diagram for steam humidifiers 1 1 2 PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED 24 VAC WIRING 2 HUMIDIFIE...

Page 4: ...To reduce the relative humidity reduce the setpoint approximately three percent relative humidity every 24 hours To increase the relative humidity increase the sepoint approximately three percent relative humidity every 24 hours Setpoint Adjustment Set the humidity setpoint according to the prevailing outdoor temperature See Table 1 for recommended settings Table 1 Recommended Humidity Controller ...

Page 5: ...ompris afin de d installer le H8908 près d un T8600 Le H8908 peut également être installé à n importe quel endroit dans la maison ou encore dans une salle d installations techniques Voir Fig 1 REMARQUE Le H8908 et le thermostat ne partagent pas le même câblage Fig 1 Humidistat H8908B Installation au mur IMPORTANT Installer le régulateur dans un endroit où la température et l humidité relative ambi...

Page 6: ... couvercle du H8908 IMPORTANT Utiliser du fil de calibre 18 à 22 pour un raccordement adéquat Fig 4 Positionnement du gabarit de la gaine de reprise MF13370 PLAQUE DE MONTAGE DU THERMOSTAT GABARIT TROUS DE FIXATION 2 TROUS POUR LE RACCORDEMENT ET INSTALLATION À DROITE UTILISER LES TROUS DE GAUCHE POUR UNE INSTALLATION À GAUCHE AUTRE EMPLACEMENT AIR REPRIS AIR REPRIS AU MOINS 152 mm 6 po AU MOINS 3...

Page 7: ...un humidificateur asservi au régulateur du ventilateur Fig 6 Schéma de raccordement type d un système avec un moteur de ventilateur à 2 vitesses Fig 7 Schéma de raccordement type d un relais détecteur de courant et d un humidificateur Fig 8 Schéma de raccordement type d un interrupteur à ailette et d un humidificateur Fig 9 Schéma de raccordement type d humidificateurs à vapeur 1 1 2 ALIMENTATION ...

Page 8: ...midité relative abaisser le point de consigne d environ 3 tous les 24 heures Afin d augmenter l humidité relative hausser le point de consigne de 3 tous les 24 heures Réglage du point de consigne Régler le point de consigne de l humidité selon la température extérieure Consulter le Tableau 1 pour obtenir les réglages recommandés Tableau 1 Réglages recommandés du régulateur d humidité FONCTIONNEMEN...

Reviews: