21
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The burner will not
light with a match.
NOTICE: Some states do not allow the exclusion or limitation of incidental or consequential damages
or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not
1. Match not reaching burners(wh-
en hoiding match with hand).
2. Empty tank.
3. Poor connection between valve
regulator and LP cylinder coupling.
4. Burner inlet blocked.
1. Use match holder found in right door.
2. Check fuel level and refill tank if necessary.
3. Turn off grill knobs,close the cylinder valve
at top of cylinder and check the connection b-
etween the regulator valve and cylinder coup-
ling.
Disconnect and reconnect,if necessary.
4. Clean the burner inlet (venturi) and burner
as described by the Care and Mainternance
section in the manual.
1. Tank valve not on or fully opened.
2. Empty tank.
3. Poor connection between valve
regulator and LP cylinder coupling.
4. Burner inlet blocked.
1. Fully open tank valve by turning counterclo-
ckwise.
2. Check fuel level and replace fuel if necess-
ary.
3. Turn off grill knobs,close the LP cylinder va-
lve at top of cylinder and check the regulator
valve and cylinder coupling.
Disconnect and reconnect,if necessary.
4. Clean the burner inlet (venturi) and burners
as described by the Care and Maintenance
section in the manual.
which may vary from state to state.
Item Name: 4-Burner LP Gas Grill With Side Burner
Main Burner Total rated BTU: 32,000 BTU/Hr
Side Burner rated BTU: 10,000 BTU/Hr
Model #: G
410