Part No: 4417341 Revision 10
Installation Manual 31
954 SmartServo FlexLine
Non-intrinsically Safe Cabling
Mains cabling: Must be suitable for the 954 SmartServo FlexLine power rating and,
moreover, approved for the use in hazardous areas.
Honeywell Enraf field bus lines may be interchanged. If local regulations allow, mains and
Honeywell Enraf field bus lines may share one cable.
Mind the isolation voltage of the cores in the cable; refer to the International Standard IEC
61010-1.
NOTE:
If a quad cable is used and all four cores are twisted together, use two opposite cores for
Honeywell Enraf field bus lines and the two others for mains.
Terminal information:
Solid / stranded
: 0.5…6 / 1.5…4
Flexible / stranded wire with end
: 0.5…4 / 0.5…2.5
Tightening torque range (clamping)
: 0.6…0.8 Nm (M 3)
Stripping length / Blade size
: 8 / 0.6 x 3.5 mm
Figure 11
Wiring Connection Descriptions