ELECTRICAL INSTALLATION

 

 

4

  

 

 

 

 

 

 

 

 

 

107137-20 -EN  FR26  GLO  305  Printed in Germany

 

ELECTRICAL SHOCK 

Remove power from FF-SR Series control modules and 
machine during installation. 

Failure to comply with these instructions could 
result in death or serious injury.

 

 

Multiple  wiring  configurations  are  possible  for  the           
FF-SRE6029 extension control module and only general 
guidelines are provided in this installation manual.  
 

Refer to the important application warnings (page 5) 
and the application examples (pages 6 through 7) for 
more details. 

 

FIGURE 7. TERMINAL ARRANGEMENT 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FUNCTIONAL DESCRIPTION 

In the case of an emergency stop condition, the safety 
device connected to the FF-SRE6029  module is actuated  
and the internal safety relays K1 and K2 de-energise. The 
normally open safety contacts (13/14…43/44) will open 
and the normally closed safety contacts (51/52) will close.  
 
The emergency stop condition is signalled to the machine 
control circuitry by the module’s safety contacts to stop the 
hazard and remove power. 
 
As soon as the safety device is released, power is applied 
to A1(+)/A2(-), A3(+)/A4(-) and the relays K1 and K2 
energise. The normally open contacts will close and the 
normally closed contact will open.  
 
Both relays K1 and K2 must be energized to have the 
normally open contacts in a closed condition. If one of the 
safety relays de-energizes, the normally open contacts will 
open.  

 

One or more FF-SRE6029 Extension Modules can be 
cascaded or external contactors with positive guided 
safety contacts can be used to increase the number of 
contacts. 
 
If multiple safety contacts are used in parallel with one 
load, the maximum admissible current can be increased.

 

 
LED INDICATORS 

The FF-SRE6029 module has two green LED status 
indicators (K1 and K2) as illustrated in Figure 8. 
Illuminated K1 and/or K2 LEDs indicate(s) that the 
corresponding internal safety relay is energized.  

 
FIGURE 8. MODULE FRONT PANEL 
 

13

14

23

24

34

44

A3
(+)

A4

(-)

Y1

Y2

33

43

A1
(+)

A2

(-)

51

52

K1

13 23 33 43

51

52

Y1

14 24 34 44

Y2

K2

Honeywell

FF-SRE60292

 

 

FSR

E

6029

10 

Summary of Contents for FF-SRE6029

Page 1: ...masterelectronics com onlinecomponents com are authorized e commerce distributors of electronic components See full Datasheet below BUY NOW BUY NOW HONEYWELL FF SRE60292 ...

Page 2: ...PROVALS CE The product packaging and documentation of FF SR Series products carry the CE mark the CE declaration of conformity is attached on the last page cURus pending This product is currently being assessed by Underwriters Laboratories Inc according to Canadian and U S safety requirements DIRECTIVE COMPLIANCE Machinery Directive 98 37 EC Low Voltage Directive 73 23 EC Electromagnetic Compatibi...

Page 3: ...e 15 C to 55 C 5 F to 131 F at 90 humidity max Sealing Housing IP 40 Terminals IP 20 Housing material Thermoplastic Vibration resistance IEC EN 60 068 2 6 Amplitude 0 35 mm Frequency 10 to 55 Hz Wire connection Solid wire 1 x 4 mm 2 12 AWG or 2 x 2 5 mm 2 14 AWG Stranded wire with sleeve 1 x 2 5 mm 2 14 AWG or 2 x 1 5 mm 2 16 AWG Wire conductor attachment M3 5 screw terminals Mounting Quick instal...

Page 4: ...oval FIGURE 4 MOUNTING DIMENSIONS for reference only Rail c b a a Width 22 5 mm 0 89 in b Height 90 mm 3 55 in c Depth 121 mm 4 77 in FIGURE 5 INSTALLATION DIAGRAM FSR1 FSRE5929 6 CONTROL RELIABILITY Control Reliability essentially means that the device system or interface shall be designed constructed and interfaced such that any single component failure within the device interface or system shal...

Page 5: ...the machine control circuitry by the module s safety contacts to stop the hazard and remove power As soon as the safety device is released power is applied to A1 A2 A3 A4 and the relays K1 and K2 energise The normally open contacts will close and the normally closed contact will open Both relays K1 and K2 must be energized to have the normally open contacts in a closed condition If one of the safe...

Page 6: ...t the FF SRE6029 extension module to safety devices WITHOUT the EDM function e g FF SYA FF SG FF SLG or FF SLG30 The External Device Monitoring EDM function checks the correct operation of the internal relays before each FF SRE6029 activation and is able to detect failures of the internal relays e g welded safety relay contacts ALWAYS connect the normally closed contact Y1 Y2 of the extension modu...

Page 7: ... The normally open contacts will close and the normally closed contacts will open The LED relay output indicators all illuminate This action will allow the machine to operate FSRE6029_12 APPLICATION NOTES Note A Dual channel output safety devices with relay outputs or safety switches examples This may be a safety device with dual output safety switching devices OSSD emergency stop push button safe...

Page 8: ...acts of the FF SRE6029 module will close and the normally closed contacts will open The LED relay output indicators K1 and K2 illuminate This action will allow the machine to operate FSRE6029_13 APPLICATION NOTES Note A Dual channel output safety devices with static safety outputs AND External Device Monitoring EDM function e g FF SYB safety light curtains Note B CONFIGURATION CARDS Various mode s...

Page 9: ...heck for external causes wiring etc Damaged contacts Ensure maximum load is specification Replace module Are the outputs contacts 13 14 43 44 closed Are K1 AND K2 LEDs OFF Are the contacts 51 52 AND Y1 Y2 closed Replace safety module and activate restart circuitry Is voltage between A1 A2 AND A3 A4 present AND within specifications Yes Machine Working Is the problem resolved No Yes Yes No No No wi...

Page 10: ...nd through our literature and the Honeywell Website it is up to the customer to determine the suitability of the product in the application Specifications may change at any time without notice The information we supply is believed to be accurate and reliable as of this printing However we assume no responsibility for its use TELEPHONE 61 0 2 9370 4500 Australia 33 0 1 60 19 80 40 France 49 0 69 80...

Reviews: