Honeywell FF-SRE6029 Instructions For Use Manual Download Page 10

 
 

 

WARRANTY AND REMEDY 

Honeywell warrants goods of its manufacture as being free 
of defective materials and faulty workmanship.  Contact 
your local sales office for warranty information.  If 
warranted goods are returned to Honeywell during the 
period of coverage, Honeywell will repair or replace without 
charge those items it finds defective.  The foregoing is 
Buyer’s sole remedy and is 

in lieu of all other warranties, 

expressed or implied, including those of 
merchantability and fitness for a particular purpose. 

 

 

 

Honeywell  

21, chemin du Vieux Chêne 
38240 Meylan 
France

 

 

 

 

 

While we provide application assistance, personally and 
through our literature and the Honeywell Website, it is up to 
the customer to determine the suitability of the product in 
the application. 
Specifications may change at any time without notice.  The 
information we supply is believed to be accurate and 
reliable as of this printing. However, we assume no 
responsibility for its use. 
 

 

TELEPHONE 

+ 61 (0) 2 9370 4500 

Australia 

+ 33 (0) 1 60 19 80 40 

France 

+ 49 (0) 69 8064 444 

Germany 

+ 34 91 313 61 00 

Spain 

+ 1-815-235-6847 

International 

+ 44 (0) 1698 481 481 

UK 

+ 1-800-537-6945 

USA & Canada 

FAX 

+ 61 (0) 2 9370 4525 

Australia 

+ 33 (0) 1 60 19 81 73 

France 

+ 49 (0) 69 8064 442 

Germany 

+ 34 91 313 61 29 

Spain 

+ 44 (0) 1698 481 676 

UK 

+ 1-815-235-6545 

USA & Canada 

 

INTERNET 

http://www.honeywell.com/sensing/ 
[email protected]

 

©  2005 Honeywell International Inc.  
All rights reserved. 

 

 
ORDER GUIDE 

 

 

FF-SRE6029

2 = 24 Vac/dc

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for FF-SRE6029

Page 1: ...masterelectronics com onlinecomponents com are authorized e commerce distributors of electronic components See full Datasheet below BUY NOW BUY NOW HONEYWELL FF SRE60292 ...

Page 2: ...PROVALS CE The product packaging and documentation of FF SR Series products carry the CE mark the CE declaration of conformity is attached on the last page cURus pending This product is currently being assessed by Underwriters Laboratories Inc according to Canadian and U S safety requirements DIRECTIVE COMPLIANCE Machinery Directive 98 37 EC Low Voltage Directive 73 23 EC Electromagnetic Compatibi...

Page 3: ...e 15 C to 55 C 5 F to 131 F at 90 humidity max Sealing Housing IP 40 Terminals IP 20 Housing material Thermoplastic Vibration resistance IEC EN 60 068 2 6 Amplitude 0 35 mm Frequency 10 to 55 Hz Wire connection Solid wire 1 x 4 mm 2 12 AWG or 2 x 2 5 mm 2 14 AWG Stranded wire with sleeve 1 x 2 5 mm 2 14 AWG or 2 x 1 5 mm 2 16 AWG Wire conductor attachment M3 5 screw terminals Mounting Quick instal...

Page 4: ...oval FIGURE 4 MOUNTING DIMENSIONS for reference only Rail c b a a Width 22 5 mm 0 89 in b Height 90 mm 3 55 in c Depth 121 mm 4 77 in FIGURE 5 INSTALLATION DIAGRAM FSR1 FSRE5929 6 CONTROL RELIABILITY Control Reliability essentially means that the device system or interface shall be designed constructed and interfaced such that any single component failure within the device interface or system shal...

Page 5: ...the machine control circuitry by the module s safety contacts to stop the hazard and remove power As soon as the safety device is released power is applied to A1 A2 A3 A4 and the relays K1 and K2 energise The normally open contacts will close and the normally closed contact will open Both relays K1 and K2 must be energized to have the normally open contacts in a closed condition If one of the safe...

Page 6: ...t the FF SRE6029 extension module to safety devices WITHOUT the EDM function e g FF SYA FF SG FF SLG or FF SLG30 The External Device Monitoring EDM function checks the correct operation of the internal relays before each FF SRE6029 activation and is able to detect failures of the internal relays e g welded safety relay contacts ALWAYS connect the normally closed contact Y1 Y2 of the extension modu...

Page 7: ... The normally open contacts will close and the normally closed contacts will open The LED relay output indicators all illuminate This action will allow the machine to operate FSRE6029_12 APPLICATION NOTES Note A Dual channel output safety devices with relay outputs or safety switches examples This may be a safety device with dual output safety switching devices OSSD emergency stop push button safe...

Page 8: ...acts of the FF SRE6029 module will close and the normally closed contacts will open The LED relay output indicators K1 and K2 illuminate This action will allow the machine to operate FSRE6029_13 APPLICATION NOTES Note A Dual channel output safety devices with static safety outputs AND External Device Monitoring EDM function e g FF SYB safety light curtains Note B CONFIGURATION CARDS Various mode s...

Page 9: ...heck for external causes wiring etc Damaged contacts Ensure maximum load is specification Replace module Are the outputs contacts 13 14 43 44 closed Are K1 AND K2 LEDs OFF Are the contacts 51 52 AND Y1 Y2 closed Replace safety module and activate restart circuitry Is voltage between A1 A2 AND A3 A4 present AND within specifications Yes Machine Working Is the problem resolved No Yes Yes No No No wi...

Page 10: ...nd through our literature and the Honeywell Website it is up to the customer to determine the suitability of the product in the application Specifications may change at any time without notice The information we supply is believed to be accurate and reliable as of this printing However we assume no responsibility for its use TELEPHONE 61 0 2 9370 4500 Australia 33 0 1 60 19 80 40 France 49 0 69 80...

Reviews: