Honeywell FF-SRE6029 Instructions For Use Manual Download Page 2

 

 

FF-SRE6029 

Extension Module

 

Instructions for use 

 

 

 

(pending)

 

 

(pending) 

 

 

 

107137-20 -EN  FR26  GLO  305  Printed in Germany 

 

1

 

 

IMPROPER INSTALLATION 

• 

Consult with US, Canadian and/or European safety 

agencies and their requirements when designing a 
machine control, interface and all control elements that 
affect safety. 

• 

Strictly adhere to all installation instructions

.

 

Failure to comply with these instructions could result 
in death or serious injury. 

 
PRODUCT DESCRIPTION 

The FF-SRE6029 Extension Module provides contact 
multiplication for safety devices with External Device 
Monitoring (EDM) capability (e.g. FF-SRS e-stop 
modules,  FF-SYB  and  FF-SB  safety  light  curtains,       
FF-SM safety mats). 
This product has two safety relays with positive-guided 
contacts to ensure redundancy and offers four NO and 
one NC safety contact. 
Its slim housing of only 22,5 mm (0.89 in) width allows 
this safety control module to fit into most cabinets and 
even helps to keep the overall cabinet size small. 

 

APPROVALS 

CE 

The product, packaging and documentation 
of FF-SR Series products carry the CE 
mark; the CE declaration of conformity is 
attached on the last page. 

cURus 
(pending) 

This product is currently being assessed 
by Underwriters Laboratories Inc. 
according to Canadian and U.S. safety 
requirements. 

 
 
 
 
 

 

DIRECTIVE COMPLIANCE 

Machinery Directive 98/37/EC 
Low Voltage Directive 73/23/EC 
Electromagnetic Compatibility Directive 89/336/EC 

 

REGULATION COMPLIANCE 

Regulation Title 

OSHA 29 CFR 
1910.217 

Requirements and 
Safeguarding of Mechanical 
Power Presses 

 

STANDARD COMPLIANCE 

Standard Title 

EN 292 

Safety of Machinery - Basic 
Concepts, General Principles 
for Design 

EN 60204-1 

Safety of Machinery - Electrical 
Equipment of Machines 

EN 954-1 

Safety of Machinery - Safety 
related parts of control system 

ANSI B11.1 

Construction, Care and Use of 
Mechanical Power Presses 

ANSI B11.2 

Construction, Care and Use of 
Hydraulic Power Presses 

ANSI B11.19 

Safeguarding Performance 
Criteria for the Design, 
Construction, Care and Use 

ANSI/RIA R15.06 

Safety Requirements for 
Industrial Robots and Robot 
Systems  

UL 508 

Industrial Control Equipment 

NFPA79 

Electrical Standard for Industrial 
Machinery  

Summary of Contents for FF-SRE6029

Page 1: ...masterelectronics com onlinecomponents com are authorized e commerce distributors of electronic components See full Datasheet below BUY NOW BUY NOW HONEYWELL FF SRE60292 ...

Page 2: ...PROVALS CE The product packaging and documentation of FF SR Series products carry the CE mark the CE declaration of conformity is attached on the last page cURus pending This product is currently being assessed by Underwriters Laboratories Inc according to Canadian and U S safety requirements DIRECTIVE COMPLIANCE Machinery Directive 98 37 EC Low Voltage Directive 73 23 EC Electromagnetic Compatibi...

Page 3: ...e 15 C to 55 C 5 F to 131 F at 90 humidity max Sealing Housing IP 40 Terminals IP 20 Housing material Thermoplastic Vibration resistance IEC EN 60 068 2 6 Amplitude 0 35 mm Frequency 10 to 55 Hz Wire connection Solid wire 1 x 4 mm 2 12 AWG or 2 x 2 5 mm 2 14 AWG Stranded wire with sleeve 1 x 2 5 mm 2 14 AWG or 2 x 1 5 mm 2 16 AWG Wire conductor attachment M3 5 screw terminals Mounting Quick instal...

Page 4: ...oval FIGURE 4 MOUNTING DIMENSIONS for reference only Rail c b a a Width 22 5 mm 0 89 in b Height 90 mm 3 55 in c Depth 121 mm 4 77 in FIGURE 5 INSTALLATION DIAGRAM FSR1 FSRE5929 6 CONTROL RELIABILITY Control Reliability essentially means that the device system or interface shall be designed constructed and interfaced such that any single component failure within the device interface or system shal...

Page 5: ...the machine control circuitry by the module s safety contacts to stop the hazard and remove power As soon as the safety device is released power is applied to A1 A2 A3 A4 and the relays K1 and K2 energise The normally open contacts will close and the normally closed contact will open Both relays K1 and K2 must be energized to have the normally open contacts in a closed condition If one of the safe...

Page 6: ...t the FF SRE6029 extension module to safety devices WITHOUT the EDM function e g FF SYA FF SG FF SLG or FF SLG30 The External Device Monitoring EDM function checks the correct operation of the internal relays before each FF SRE6029 activation and is able to detect failures of the internal relays e g welded safety relay contacts ALWAYS connect the normally closed contact Y1 Y2 of the extension modu...

Page 7: ... The normally open contacts will close and the normally closed contacts will open The LED relay output indicators all illuminate This action will allow the machine to operate FSRE6029_12 APPLICATION NOTES Note A Dual channel output safety devices with relay outputs or safety switches examples This may be a safety device with dual output safety switching devices OSSD emergency stop push button safe...

Page 8: ...acts of the FF SRE6029 module will close and the normally closed contacts will open The LED relay output indicators K1 and K2 illuminate This action will allow the machine to operate FSRE6029_13 APPLICATION NOTES Note A Dual channel output safety devices with static safety outputs AND External Device Monitoring EDM function e g FF SYB safety light curtains Note B CONFIGURATION CARDS Various mode s...

Page 9: ...heck for external causes wiring etc Damaged contacts Ensure maximum load is specification Replace module Are the outputs contacts 13 14 43 44 closed Are K1 AND K2 LEDs OFF Are the contacts 51 52 AND Y1 Y2 closed Replace safety module and activate restart circuitry Is voltage between A1 A2 AND A3 A4 present AND within specifications Yes Machine Working Is the problem resolved No Yes Yes No No No wi...

Page 10: ...nd through our literature and the Honeywell Website it is up to the customer to determine the suitability of the product in the application Specifications may change at any time without notice The information we supply is believed to be accurate and reliable as of this printing However we assume no responsibility for its use TELEPHONE 61 0 2 9370 4500 Australia 33 0 1 60 19 80 40 France 49 0 69 80...

Reviews: