Checking RF communication

4.10.2 

HB85 sends test signals to the 

evotouch controller in order 

to test the signal strength.

Press the bind button of the HB85 briefly.

 

f

For approx. 10 minutes, HB85 transmits a test message 

to the 

evotouch

 controller every 5 seconds.

The  field  strength  is  indicated  on  the 

evotouch

 

controller.

 The  signal  strength  can  be  EXCELLENT,  GOOD, 

POOR or not received

 

 

Completing configuration

Press the DONE button.

 

f

Configuration of the HB85 temperature sensor is completed.

Summary of Contents for EVOTOUCH CONTROLLER

Page 1: ...1 Application Manual ...

Page 2: ...oiler control with up to 4 controllers 22 3 Application settings 23 4 Generic Binding 24 4 1 Configuration modes 24 4 2 Sensor binding 27 4 3 Binding the evotouch controller to the HR80 radiator controller 28 4 4 Binding the evotouch controller to the BDR91 HC60NG R6660D relay module 31 4 5 Binding the evotouch controller to the OPENTHERM Bridge boiler feedback 33 4 6 Binding the evotouch controll...

Page 3: ...ing solutions particularly for radiator underfloor and electrical heating control Wireless communication 1 1 The peripherals communicate with the evotouch controller based on our proven RF wireless technology 868 MHZ The products include a transceiver which allows bi directional two way communication or uni directional one way communication with the evotouch controller DT92 HCW82 HCF82 HB85 HCE80 ...

Page 4: ...C80R has the same configuration but instead an analogue output it has an integrated boiler relay External antenna HRA80 External active antenna for HCE80 R Up to 3 controllers can be connected to one antenna transceiver 868 MHz OPENTHERM Bridge R8810A1018 OPENTHERM Bridge interface for boiler control heat on demand transceiver 868 MHz Extension module HCS80 3 zones upgrade for HCE80 R HCC80 R from...

Page 5: ...lant Oventrop available Battery powered 2x1 5 V AA LR6 transceiver 868 MHz Relay module 5 A BDR91 Relay module with change over contact 5 A transceiver 868 MHz Relay module 8 A HC60NG R6660D Relay module with change over contact 8 A receiver 868 MHz Outdoor sensor HB85 Module with integrated temperature sensor for measuring the outside temperature Battery powered 2x1 5 V AA LR6 transmitter 868 MHz...

Page 6: ...mples 2 Single zone thermostat with boiler control 2 1 HB85 BDR91 evotouch Boiler room Zone 1 Zone 1 Notes The internal room sensor of the evotouch controller must be activated BDR91 relay module or OPENTHERM Bridge can be used ...

Page 7: ...internal room sensor of the evotouch controller is used in order to measure the room temperature Option Outdoor sensor The HB85 outdoor sensor measures the outside temperature It must be installed if data is required Steps to do Activate the internal room sensor of the f f evotouch controller See section 4 2 Bind BDR91 relay module OPENTHERM Bridge to the f f evotouch controller See section 4 4 Ch...

Page 8: ...with zone valves 2 2 BDR91 Zone 2 Zone 1 evotouch Zone 2 Boiler room Zone 1 BDR91 DT92 Notes The internal room sensor of the evotouch controller must be activated for zone 1 Instead of DT92 the HCW82 HCF82 room units can be used ...

Page 9: ...s it to the boiler relay BDR91 HC60NG or OPENTHERM Bridge which controls the boiler Outdoor sensor The HB85 outdoor sensor measures the outside temperature It must be installed if data is required Steps to do Activate the internal room sensor of the f f evotouch controller for zone 1 See section 4 2 Bind the f f evotouch controller to the DT92 as room setpoint sensor to zone 2 See section 4 8 Bind...

Page 10: ...evotouch BDR91 Zone 2 Zone 4 Zone 5 Zone 6 8 Zone 3 Boiler room Zone 1 HR80 HR80 HR80 HR80 HR80 HR80 Notes The internal room sensor of the evotouch controller must be activated for zone 1 Zone 1 HR80 internal room sensor not used Optional boiler feedback BDR91 relay module or OPENTHERM Bridge ...

Page 11: ...s the heat demand and communicates it to the boiler relay BDR91 HC60NG or OPENTHERM Bridge which control the boiler Outdoor sensor The HB85 outdoor sensor measures the outside temperature It must be installed if data is required Steps to do Activate the internal room sensor of the f f evotouch controller for zone 1 See section 4 2 Bind the f f evotouch controller to each HR80 s integrated room sen...

Page 12: ...one 4 Zone 5 Zone 6 8 Zone 3 Boiler room Zone 1 HR80 HR80 HR80 DT92 HR80 HR80 HR80 Notes The internal room sensor of the evotouch controller must be activated for zone 1 Instead of DT92 the HCW82 HCF82 room units can be used Zones 1 and 2 HR80 internal room sensor not used Optional heat demand BDR91 relay module or OPENTHERM Bridge ...

Page 13: ...emote units DT92 HCW82 or HCF82 Options Heat demand The evotouch controller calculates the heat demand and communicates it to the boiler relay BDR91 HC60NG or OPENTHERM Bridge which control the boiler Outdoor sensor The HB85 outdoor sensor measures the outside temperature It must be installed if data is required Steps to do Activate the internal room sensor of the f f evotouch controller for zone ...

Page 14: ...ible evotouch HCE80 R HCC80 R BDR91 R Zone 2 Zone 4 Zone 5 Zone 6 8 Zone 3 Boiler room Zone 1 DT92 DT92 DT92 DT92 DT92 Notes The internal room sensor of the evotouch controller must be activated for zone 1 Instead of DT92 the HCW82 HCF82 room units can be used Optional boiler feedback BDR91 relay module or OPENTHERM Bridge ...

Page 15: ...at demand and communicates it to the boiler relay BDR91 HC60NG or OPENTHERM Bridge which control the boiler Outdoor sensor The HB85 outdoor sensor measures the outside temperature It must be installed if data is required Steps to do Activate the internal room sensor of the f f evotouch controller for zone 1 See section 4 2 Bind the f f evotouch controller to each room unit DT92 individually for zo...

Page 16: ...nes up to 8 zones are possible evotouch BDR91 Zone 2 Zone 4 Zone 5 Zone 6 8 Zone 3 Boiler room Zone 1 HCF82 HCF82 HCF82 HCF82 HCF82 HCE80 R HCC80 R Notes The internal room sensor of the evotouch controller must be activated for zone 1 Optional heat demand BDR91 relay module or OPENTHERM Bridge ...

Page 17: ...calculates the heat demand and communicates it to the boiler relay BDR91 HC60NG or OPENTHERM Bridge which controls the boiler Outdoor sensor The HB85 outdoor sensor measures the outside temperature It must be installed if data is required Steps to do Activate the internal room sensor of the f f evotouch controller for zone 1 See section 4 2 Bind the f f evotouch controller to the HCF82 room sensor...

Page 18: ...le or OPENTHERM Bridge For that mixed application you can setup the configuration as following Select menu GUIDED CONFIG and configure the 4 zones for radiator control f f Select menu ZONING CONFIG and add the 2 zones for underfloor heating control ADD ZONE f f Alternative go to the expert menu Select menu ZONING CONFIG and add the 4 zones for Radiator control ADD ZONE f f Select menu ZONING CONFI...

Page 19: ...ler Outdoor sensor The HB85 outdoor sensor measures the outside temperature It must be installed if data is required Steps to do Activate internal room sensor of the f f evotouch controller for zone 1 See section 4 2 Bind the f f evotouch controller to the DT92 room unit individually for zones 2 and 3 See section 4 8 Bind the f f evotouch controller to each HR80 s integrated room sensor individual...

Page 20: ...odule or OPENTHERM Bridge For that mixed application you can setup the configuration as following Select menu GUIDED CONFIG and configure the 5 zones for radiator control f f Select menu ZONING CONFIG and add the 1 zone for underfloor heating control ADD ZONE f f Alternative go to the expert menu Select menu ZONING CONFIG and add the 5 zones for Radiator control ADD ZONE f f Select menu ZONING CON...

Page 21: ...eat demand The evotouch controller calculates the heat demand and communicates it to the BDR91 HC60NG boiler relay or OPENTHERM Bridge which control the boiler Outdoor sensor The HB85 outdoor sensor measures the outside temperature It must be installed if data is required Steps to do Activate internal room sensor of the the f f evotouch controller for zone 1 See section 4 2 Bind the f f evotouch c...

Page 22: ...ENTHERM Bridge can be used Application description The boiler relay or OPENTHERM Bridge can receive the heat demand signal from up to 4 evotouch controllers in order to control the boiler based on the required heat demand Each controller calculates the maximum heat demand and will send this information to the boiler relay Each controller must be bound to the boiler relay ...

Page 23: ...eating Parameter Settings range Optimisation Enabled disabled Window function Enabled disabled Min max temperature setpoint 5 35 C Local override Enabled disabled Mixing valve Parameter Range Default setting Mixing valve run time 0 240 s 150 s Pump run time 0 99 min 15 min Minimum flow temperature 0 50 C 15 C Maximum flow temperature 0 99 C 55 C Zone valves Parameter Settings range Fail save Enabl...

Page 24: ...ontroller to receive or transmit data In addition the RF communication can be checked and the signal strength is indicated and displayed As an example the following procedures are described for a living room Configuration modes 4 1 The zone configuration of the evotouch controller basicly can be done by the GUIDED Configuration and EXPERT Configuration Particularly if you have mixed applications e...

Page 25: ...Application Manual 25 Press the button GUIDED CONFIG f f Press the YES button f f Depending on your needs select a button to press f f Follow the next guided screens f f ...

Page 26: ... 1 2 Press the button MENU f f The next screen appears Press the button ZONING MENU f f Press the button ZONING CONFIG f f Press the button f f Press for 5 seconds to enter and hold the button for 5 seconds until the next screen appears ...

Page 27: ...trol ADD ZONE f f Select menu ZONING CONFIG and add the 3 zones for underfloor heating control ADD ZONE f f The Binding process in the EXPERT MENÜ is the same as for GUIDED CONFIGURATION however the RF test must be choosen in the MENU SYSTM CONFIGURATION BINDING AND RF TEST individual for each zone Sensor binding 4 2 To each zone a room sensor must be assigned This can be an internal sensor or an ...

Page 28: ...or 4 3 1 Follow the guided or expert configuration until the f f following screen appears Position the f f evotouch controller close to the HR80 which is connected to the valve Press the bind button 1 on the HR80 f f After successful binding the following screen appears i NEXT leads you to the binding of the actuator ...

Page 29: ...tton on the f f evotouch controller to send the signal The symbol flashes and the software version number is displayed for 30 seconds During the binding procedure the symbol is shown continuously in the display of the HR80 radiator controller The display shows sync The HR80 radiator controller is receiving data from the evotouch controller This process can take up to 4 minutes i The binding proced...

Page 30: ...EXCELLENT GOOD POOR or not received HR80 receiving test signal from the evotouch controller While f f TesT is displayed press the bind button 1 on the HR80 The HR80 radiator controller is ready to receive the test message from the evotouch controller The first two digits in the display indicate the number of received test messages and the right hand digit indicates the field strength 1 sufficient ...

Page 31: ...has been activated i After the power up of the BDR91 relay module the red LED will start to flash at 0 1 s ON 0 9 s OFF If this is not the case set the BDR91 into the reset mode see instructions BDR91 HC60NG BDR91 HC60NG R6660D Position the f f evotouch controller as close as possible to the BDR91 HC60NG R6660D relay module s Press the BIND button on the f f evotouch controller to send the bind si...

Page 32: ...0D The evotouch controller sends test signals to the assigned relay module HC60NG R6660D in order to test the signal strength When HC60NG R6660D receives the test signal the field strength is indicated by flashing of the red LED 1 pulse sufficient 5 pulses strong Deactivating the RF communication check Press the NEXT button f f Completing configuration In the following screen press the DONE button...

Page 33: ...ction 4 4 Binding procedure 4 5 1 Follow the guided or expert configuration until the f f following screen appears Press and hold the bind button 1 of the OPENTHERM f f Bridge for 5 seconds to activate the bind mode Press the BIND button on the the f f evotouch controller to send the bind signal to the OPENTHERM Bridge The red LED of the OPENTHERM Bridge is switched off to confirm a successful bin...

Page 34: ...ngth When OPENTHERM Bridge receives the test signal the field strength is indicated by flashing of the red LED 1 pulse sufficient 5 pulses strong Deactivating the RF communication check Press the NEXT button f f Completing configuration In the following screen press the DONE button f f Configuration of the OPENTHERM Bridge boiler feedback is completed ...

Page 35: ...s 1 and 2 at the HM80 for approx f f 4 seconds until the LED 3 flashes regularly 3 1 2 Position the f f evotouch controller as close as possible to the HM80 mixing valve controller Press the BIND button on the f f evotouch controller to send the bind signal to the HM80 mixing valve controller The LED 3 of the HM80 is switched OFF to confirm a successful binding i Binding is terminated automaticall...

Page 36: ...ignal the field strength is indicated by flashing of the red LED 4 1 pulse sufficient 5 pulses strong Note Sensor information relates to the sensor in the zone controlled by the HM80 Deactivating the RF communication check Press the NEXT button f f Completing configuration In the following screen press the DONE button f f Configuration of the HM80 mixing valve is completed ...

Page 37: ...appears Press and hold the installation button 1 at the f f underfloor heating controller for approx 2 seconds The LED of zone 1 flashes red 1 3 2 Position the f f evotouch controller as close as possible to the underfloor heating controller Press the BIND button on the f f evotouch controller to send the bind signal to the underfloor heating controller The LED of the selected one lights continuou...

Page 38: ...es green 1 3 2 Position the f f evotouch controller as close as possible to the underfloor heating controller Press the BIND button on the f f evotouch controller to send the bind signal to the underfloor heating controller The LED of zone 1 2 lights continuously green Binding of further zones i In order to assign further zones press the installation button again until the LED of the desired zone ...

Page 39: ...ves the test signal the field strength is indicated by flashing of the green zone LED 2 1 pulse sufficient 5 pulses strong Note Sensor information relates to the sensor in the zone controlled by the HCE80 Deactivating the RF communication check Press the NEXT button f f Completing configuration In the following screen press the DONE button f f Configuration of the HCE80 R HCC80 R underfloor heatin...

Page 40: ... appears Position the f f evotouch controller as close as possible to the DT92 Press and hold both arrows up and down until the f f display changes Press button 1 f f Binding takes place automatically i Press button 1 approx 5 sec when the display on DT92 does not appear as pictures shows i The binding mode remains active for max 10 minutes after the last button was pressed 1 ...

Page 41: ...t the signal strength The device is now in the test mode and sends test signals to the evotouch controller i The signal strength can be EXCELLENT GOOD POOR or not received Deactivating the RF communication check Remove and re insert the batteries of the DT92 f f Completing configuration Press the DONE button f f Configuration of the DT92 room adjuster sensor is completed ...

Page 42: ... 9 1 Follow the guided or expert configuration until the f f following screen appears Position the f f evotouch controller as close as possible to the HCW82 HCF82 Press and hold the bind button 1 on the HCF82 f f HCW82 for approx 1 second Binding takes place automatically i Binding is terminated automatically after 5 minutes 1 2 ...

Page 43: ...e signal strength Press and hold the bind button of the HCW82 HCF82 f f for at least 30 seconds until the red LED extinguishes The device is now in test mode and sends a test signal every 5 seconds The LED 2 flashes briefly at every test signal The field strength is indicated on the evotouch controller i The signal strength can be EXCELLENT GOOD POOR or not received ...

Page 44: ...10 Binding procedure 4 10 1 i To check whether the radio connection is ready for later operation during binding the temperature sensor module should remain as near as possible to the mounting site Follow the guided or expert configuration until the f f following screen appears Press the bind button 1 on the HB85 f f Binding takes place automatically i Binding is terminated automatically after 4 mi...

Page 45: ... button of the HB85 briefly f f For approx 10 minutes HB85 transmits a test message to the evotouch controller every 5 seconds The field strength is indicated on the evotouch controller i The signal strength can be EXCELLENT GOOD POOR or not received Completing configuration Press the DONE button f f Configuration of the HB85 temperature sensor is completed ...

Page 46: ...46 evotouch ...

Page 47: ...Application Manual 47 ...

Page 48: ...of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl Rolle Z A La Pièce 16 Switzerland by its Authorized Representative Honeywell Control System Ltd Arlington Business Park Bracknell Berkshire RG12 1EB Technical Help Desk 08457 678999 www honeywelluk com ...

Reviews: