Average temperature measurement with MRT
___________________________________________________________________________
Instruction manual VITO
Page 22
Item
Name
Description
MO
=
Temperature element offset
Format according to item LD (default: +000.0000 m).
The offset represents the distance from the tank zero level to the
lowest position of the MRT.
Note:
In case of ullage measurement, distance
MO
is taken from the
upper reference point.
MI
=
Switch hysteresis
Format according to item
LD
(default: +000.1000 m).
The distance
MI
is a hysteresis around the switching point of the
temperature elements.
MP
=
Product immersion depth
Format according to item
LD
(default: +000.5000 m).
The distance
MP
specifies the minimum required liquid level
above an element before it is selected for the average product
temperature calculation.
MG
=
Gas immersion depth
Format according to item L
D
. (default: +000.5000 m).
The distance
MG
specifies the minimum required distance before
the resistance value of the longest element is taken in the
average gas temperature calculation
TU
=
Temperature status conversion
One character (default: ‘T’)
This item is used to indicate the temperature status character in
case of a reduced or not guaranteed temperature accuracy. This
is the case when the temperature status is:
•
out of specified temperature range
•
exceeding differential temperature range
•
last valid level used
•
manual level used
•
level below lowest temperature element
If required, this item can be set to another character.
EX
Exit
Exit protection level 2