INSTALLATION INSTRUCTIONS

31-00432M-01

CS/CSP/MCS Series Current 
Switches

WARNING

Failure to follow these instructions will result in 
death or serious injury.

AVERTISSEMENT

Le non-respect de ces instructions entraîne un 
risque de blessures graves, voire la mort.

WARNING

This product can expose you to chemicals 
including 1,3 Butadiene, which is known to the 
State of California to cause cancer and 
reproductive harm. For more information, go to 
www.P65Warnings.ca.gov

AVERTISSEMENT

Ce produit peut vous exposer à des produits 
chimiques, dont le 1,3-Butadiène, considéré par 
l'État de Californie comme étant cancérigène et 
nocif pour la reproduction. Pour en savoir plus, 
consultez le site www.P65Warnings.ca.gov

CAUTION

Hazard of electrical shock, explosion, and arc 
flash

• Follow ALL requirements in NFPA 70E for safe work 

practices and for Personal Protective Equipment (USA) 
and other applicable local codes when installing this 
product

• Only qualified electrical personnel should install this 

product

• Read, understand, and follow all instructions 

thoroughly

• Install only on insulated conductors
• Lock out and tag out all power sources prior to 

installation. Use properly rated voltage sensing 
instrument to determine no voltage is present 

MISE EN GARDE

Risque de décharge électrique, d’explosion et 
d’arc électrique

• Respectez TOUTES les exigences de la norme 

NFPA 70E concernant les pratiques de travail 
sécuritaires et les équipements de protection 
individuelle (États-Unis), ainsi que les autres codes 
locaux applicables lors de l’installation de ce produit

• Seul le personnel qualifié dans le domaine électrique 

est autorisé à installer ce produit

• Lisez, comprenez et respectez scrupuleusement toutes 

les instructions

• N'installez que sur les conducteurs isolés
• Verrouillez et étiquetez toutes les sources 

d’alimentation avant l’installation. Utilisez un détecteur 
avec la tension nominale appropriée pour déterminer 
l'absence de tension

CAUTION

Automated equipment may start without 
warning

• Equipment monitored/operated by this device may 

start without warning. Keep clear of apparatus at all 
times

IMPORTANT 

• Only qualified trade installers should install this 

product

• This product is not intended for life-safety applica-

tions

• Do not install in hazardous or classified locations
• The installer is responsible for all applicable codes
• This product must be installed in a suitable electri-

cal enclosure

• Clamp sensor around INSULATED CONDUCTOR 

ONLY, 600VAC MAX to be monitored.

Summary of Contents for CS Series

Page 1: ...r to installation Use properly rated voltage sensing instrument to determine no voltage is present MISE EN GARDE Risque de décharge électrique d explosion et d arc électrique Respectez TOUTES les exigences de la norme NFPA 70E concernant les pratiques de travail sécuritaires et les équipements de protection individuelle États Unis ainsi que les autres codes locaux applicables lors de l installatio...

Page 2: ... exceed 30VAC DC Tighten ter minals to 3 5 in lb For CS MCS solid core sensors 1 Drill a single 3 32 pilot hole for mounting the sen sor ensure no drill shavings are present in enclo sure 2 Insert INSULATED CONDUCTOR ONLY 600VAC MAX to be monitored through the iris of the sensor 3 Reconnect the conductor and torque appropriately 4 Wire the output of the sensor to a control panel digi tal input loo...

Page 3: ...hrown away in regular trash Instead it should be recycled according to local municipality CSP NO F CS NO F OPERATION The CSP NO F 200A output changes state whenever current above 0 35A is present THE CS NO F 50A output changes state above 0 25A This provides go no status on loads that are not subject to mechanical failures Typical on off status applications include Lighting circuits Heater element...

Page 4: ...insi que les autres codes locaux applicables lors de l installation de ce produit Lisez attentivement tous les avertissements 1 Adjust knob on sensor to maximum FLA Fully clockwise 2 With motor operating normally adjust knob SLOWLY counter clockwise until Hi LED is lit Fig 1 Normal Operation 1 Set knob to motor FLA Fig 2 Small Lightly Loaded Motor Operation 1 Set knob proportionally below FLA 2 Be...

Page 5: ...t switch will provide a true status output as shown in the chart above CSP NO AECM SETUP ALTERNATE Follow all safety precautions outlined in this manual Follow all requirements in NFPA 70E for safe work practices and for Personal Protective Equipment USA and other applicable local codes when installing this product Read all warnings carefully Respectez toutes les précautions de sécurité décrites d...

Page 6: ...Frequency 60Hz 0Hz VFD Broken Belt VFD Normal Operation Trip Area 40Hz Cal Trip Area 50Hz Cal Trip Point 40Hz Trip Point 50Hz Table 2 Specification by Product Product Number Trip Point Core Type Max Current CS NO F 50A Fixed 0 25A SOLID 50A CSP NO F 200A Fixed 0 35A SPLIT 200A MCS NO A 50A Adjustable 0 75 50FLA SOLID 50A CS NO A 50A Adjustable 0 75 50FLA SOLID 50A CSP NO A 100A Adjustable 0 50 100...

Page 7: ...F 200A 0 75 CS NO F 50A 0 52 ADJUSTABLE CURRENT SWITCHES Turn on Amperage CSP NO AVFD 150A 1A 30Hz min 1 5A 20Hz min 2 5A 10Hz min Output Type NO solid state FET Temperature Rating 15 60 C Insulation Class 600V RMS For use on insulated conductors only Use minimum 75 C insulated conductor Sensor Power Induced Frequency Range 50 60Hz CSP NO AVFD 150A 10 120Hz proof of flow loss alarm at 40Hz Dimensi...

Page 8: ...ITCHES Honeywell Building Technologies In the U S Honeywell 715 Peachtree Street NE Atlanta GA 30308 customer honeywell com U S Registered Trademark 2020 Honeywell International Inc 31 00432M 01 M S 10 20 Printed in United States ...

Reviews: