1. PREFACE
This manual is designed to provide you with important service information. Be sure to read the
safety precautions prior to servicing the unit.
1.1 Safety Precautions
1
When servicing, set the POWER of the CONTROL PANEL to OFF and unplug the power
cord.
2
Observe the original lead dress. If a short circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
3
After servicing, make an insulation resistance test to prevent the customer’s exposure to
shock hazards.
1.2 Insulation Resistance Test
1
Unplug the power cord and connect a jumper between 2 pins.
2
The grounding conductor (green or green & yellow) is to be open.
3
Measure the resistance value with an ohm meter between the jumper lead and each exposed
metallic part on the equipment at all MODES (except POWER OFF).
4
The value should be over
1 MΩ.
1.3 Specifications
MODELS
ITEMS
CO60PM
Power Supply
120V, 50Hz
Input (W)
220W
Running Current (A)
1.83A
Fan Type
16'' metal fan blade
Fan Speeds
3
Operation Control
Control Panel
Air Direction Control
Vertical Louver (Right & Left) - Auto
Horizontal Louver (Up & Down) - Manual
Protector
Fan Motor Internal Thermal Protector
Water Pump Internal Thermal Protector
Filter
3 Sides Honeycomb media
(Back 591.5 x 538 x 40mm
2 Sides 591.5 x 270 x 40mm)
Power Cord
2.5 m (3 wire with grounding)
Water Fill System
Manual (from top cover)
Auto (from continuous water supply connection)
Drain System
Manual drain plug
Water Tank Capacity
15.8 US Gallon / 60 L*
Net Weight
39.2 lbs / 17.8 kg
Outer Dimension
(W x D x H)
27.56
’’ x 18.35” x 40.0”
700 x 466 x 1017 mm
*Due to continuous updates to product on account of compliance requirements, tank capacity
may be changed by manufacturer over a period of time