CM907-

TRV

 CHRONOTHERM

 

 

 

  

EN0H 8555 UK07 R0 09/06 

5

Parameter 

Installer Set-
Up Number / 
Abbreviation 
(Press  + or - 
keys to select) 

Factory Setting 

 

Optional Setting 

 

Installer Set-
Up Category 

(Press 
PROG keys 
‘< or >’ to 
select) 

  

Display 

Description 

Display/Setting 

Description 

 

Category 1: Thermostat Parameters 

AM-PM / 24hr 
Display 

1:Cl 

24 

24 hr clock display 

12 

12 hr AM / PM clock display 

RESET Time / 
Temperature 
Program 

2:rP 

Time / Temperature 
profile set to factory 
default 
Changes to 0 when 
one of the time/temp 
profiles are changed 

 

Time / Temperature are 
as programmed 
To restore the factory 
profile set to 1 

Automatic 
Summer/Winter 
Time Chqnge 

3:tC 1 

Automatic 
Summer/Winter Time 
Change Enabled 

0 Automatic 

Summer/Winter Time 
Change Disabled 

Backlight Display 

5:bL 

Backlight Display 
Enabled 

0 Backlight 

Display 

Disabled 

Upper 
Temperature Limit 

6:uL 

35 

35°C Upper Temp. 
Limit 

21 to 34 

21°C to 34°C 
adjustment in 1°C steps 

Lower 
Temperature Limit 

7:LL 

5°C Lower Temp. 
Limit 

6 to 21 

6°C to 21°C adjustment 
in 1°C steps 

Optimisation 

8:0P 

Optimisation disabled 

Optimisation enabled 

Remote Control 
Setpoint (e.g. via 
telephone module) 

9:tS 0 

Disabled 

Enabled 

Second 
Temperature 
Sensor    

10:SS 

No sensor fitted 

 

1, 2 

1 - Outside Temperature 
Sensor fitted 
2 - Remote Temp. 
Sensor fitted 

Temperature 
Offset 

12:tO 

No offset 

-3 to +3 

-3°C to +3°C adjustment 
in 0.1°C steps 

Proportional Band 
Width  

13:Pb 1.5 

1.5°C 

Proportional 

Band 

1.6 to 3.0 

1.6°C to 3.0°C 
adjustment in 0.1°C 
steps 

Reset Parameters 
to Factory 
Defaults 

19:FS 

All settings held are 
the factory defaults. 
Changes to 0 when 
one of the parameter 
values are changed 

Settings are as modified 
above                                
To restore the factory 
profile set to 1 

‘Category 2: System Parameters (You must  press the ‘>’ program key to enter this section) 

Minimum boiler 
ON Time   

1:Ot 

1 minute minimum ON 
time 

2 to 5 

2 - 2 minutes 
3 - 3 minutes 
4 - 4 minutes 
5 - 5 minutes 

Cycle Rate 

2:Cr 

6 cycles per hour 
(cph) for gas boilers, 
zone valves and fan-
coil 

3, 9, 12 

3 - 3 cph 
9 - 9cph 
12 - 12 cph 

Electric Heat 
 

 

3:Eh 

Applications < 3A 

Applications 3 - 5A   

Heat / Cool 
Change 

4:HC 0 

Disabled 

1 Enabled 

Summary of Contents for CM901

Page 1: ... temperature in the house The TRV mode can either be pre programmed or switched manually TRV button allows activation or cancellation of the TRV mode manually whenever this type of control is required Party feature that temporarily maintains a selectable constant temperature for 1 23 hours then returns to normal operation Holiday button that provides energy savings by reducing to a constant temper...

Page 2: ...our Room Temperature display range From 0 o C to 50 o C Control form P I Proportional Integral Minimum ON time 10 of cycle time min one minute adjustable to 2 to 5 min see installer set up Cycle rate Selectable by application see installer set up Wiring Terminal block capable of accepting wires up to 2 5 mm 2 Wire access Mains wiring rear right Low voltage wiring rear right Dimensions 133 x 89 x 2...

Page 3: ...or 5 seconds Modify the cooling program as required Heat Pump Air conditioner 3 4 1 Set Minimum ON Time to 4 minutes 2 Set Cycle Hour to 3 2 Fan coil 6 1 No action required In Installer set up we can Set up specific applications Enable special features Establish support for optional accessories To enter the installer set up mode a Move the slider switch to the OFF position b Press and hold the INF...

Page 4: ...installer set up mode to the desired limit Temperature Offset If the thermostat is located in a hot cold location and cannot be moved because of wiring then the measured displayed temperature can be adjusted by 3 o C Useful if the homeowner wants the reading to match another appliance temperature display Set parameter n 12 category 1 in the installer set up mode to the desired offset value Proport...

Page 5: ...r Temp Limit 6 to 21 6 C to 21 C adjustment in 1 C steps 1 Optimisation 8 0P 0 Optimisation disabled 1 Optimisation enabled 1 Remote Control Setpoint e g via telephone module 9 tS 0 Disabled 1 Enabled 1 Second Temperature Sensor 10 SS 0 No sensor fitted 1 2 1 Outside Temperature Sensor fitted 2 Remote Temp Sensor fitted 1 Temperature Offset 12 tO 0 No offset 3 to 3 3 C to 3 C adjustment in 0 1 C s...

Page 6: ...r lights near doors or windows or in direct sunlight MOUNTING The CM907 TRV thermostat can be mounted directly on the wall surface or on an electrical wallbox WIRING The CM907 TRV thermostat is designed for fixed wiring only and must be installed in accordance with the latest l E E regulations Ensure the wiring connection to the supply is via a fuse rated at no more than 8 amps and a Class A switc...

Page 7: ...om EN0H 8555 UK07 R0 09 06 WIRING Description Model Logo Literature Availability Spec Sheet 7 day programmable thermostat Remote Temperature Sensor Outdoor Temperature Sensor CMT907A1082 F42010972 001 F42010971 001 Honeywell Honeywell French Dutch Multi lingual Multi lingual Aug 06 Sep 06 Sep 06 ENOH8555 ENOH8554 ENOH8553 ORDERING SPECIFICATION ...

Reviews: