background image

CM907-

TRV

 CHRONOTHERM

 

 

 

EN0H 8555 UK07 R0 09/06 

INSTALLER SET-UP 

Specific Applications

 

  

Setting

 

What do you need to change?

 

 

Cycle/ 
Hour 

Minimum 
ON time 

(in minutes)

 

Note :

  

a.  To change Cycle/Hour, please go to parameter n. 2, category 2 

in the installer set-up mode. 

b.  To change Minimum ON Time, please go to parameter n. 1, 

category 2 in the installer set-up mode. 

Heating Gas 

Boilers 

(<30KW) 

No action required 

 

Oil Boiler 

1.  Set Minimum ON Time to 4 minutes.  
2.  Set Cycle/Hour to 3. 

 

Thermal Actuator 

12 

Set Cycle/Hour to 12.  

 

Zone valve 

No action required. 

 

Electric heating 
(for applications 
<8A) 

12 

1.  Configure the thermostat for electric heating (set parameter n.3, 

category 2 in the installer set up mode to 1). 

2.  Set Cycle/Hour to 12. 

Air 
conditioning 

 

 

 

1.  Configure the thermostat to allow switching between heating 

and cooling modes (set parameter n.4, category 2 in the 
installer set-up mode to 1) 

2.  Set the thermostat accordingly to the required mode of 

operation (heating or cooling) by pressing the TEMP 

 or 

 

buttons together for 5 seconds.

 Modify the cooling program 

as required. 

 

Heat Pump/ 
Air conditioner 

1.  Set Minimum ON Time to 4 minutes. 
2.  Set Cycle/Hour to 3. 

Fan coil 

No action required. 

In Installer set-up we can:

 

  Set-up specific applications 

  Enable special features 

  Establish support for optional accessories 

To enter the installer set-up mode:

a)  Move the slider switch to the 

OFF 

position. 

b)  Press and hold the 

INFO

 

i

 button and the two program 

buttons ‘

< >’

 together.  

c)  The unit will display the first parameter of installer 

parameter group category 1 (from n.1 to n.19). 

d) Press the 

TEMP

 

 or 

 buttons 

to change the factory 

setting. The display will flash indicating that a change has 
been made. 

e)  Press the green 

OK

 button to confirm this change and the 

display will stop flashing. 

f) Press 

the   

+

 button to go to the next parameter. 

g)  Press the program button

 

>

 to go to category 2 in the 

Installer mode (from n.1 to n.5). 

h)  To exit the installer mode, move the slider switch to the 

AUTO

 or 

MAN

 positions. 

 

Abbreviated Set-Up Description

 

e.g. 

Cl

 = Clock Format 

Factory Setting or New Choice

Press 

TEMP

 

 or 

 to change

e.g. 

12

 = AM/PM Format

24

= 24hr Format 

Installer Set-up Number

(Press 

+ or - to change)

e.g. 

1

 = Clock Format

Brief Description of the 
Parameter Function. 

Summary of Contents for CM901

Page 1: ... temperature in the house The TRV mode can either be pre programmed or switched manually TRV button allows activation or cancellation of the TRV mode manually whenever this type of control is required Party feature that temporarily maintains a selectable constant temperature for 1 23 hours then returns to normal operation Holiday button that provides energy savings by reducing to a constant temper...

Page 2: ...our Room Temperature display range From 0 o C to 50 o C Control form P I Proportional Integral Minimum ON time 10 of cycle time min one minute adjustable to 2 to 5 min see installer set up Cycle rate Selectable by application see installer set up Wiring Terminal block capable of accepting wires up to 2 5 mm 2 Wire access Mains wiring rear right Low voltage wiring rear right Dimensions 133 x 89 x 2...

Page 3: ...or 5 seconds Modify the cooling program as required Heat Pump Air conditioner 3 4 1 Set Minimum ON Time to 4 minutes 2 Set Cycle Hour to 3 2 Fan coil 6 1 No action required In Installer set up we can Set up specific applications Enable special features Establish support for optional accessories To enter the installer set up mode a Move the slider switch to the OFF position b Press and hold the INF...

Page 4: ...installer set up mode to the desired limit Temperature Offset If the thermostat is located in a hot cold location and cannot be moved because of wiring then the measured displayed temperature can be adjusted by 3 o C Useful if the homeowner wants the reading to match another appliance temperature display Set parameter n 12 category 1 in the installer set up mode to the desired offset value Proport...

Page 5: ...r Temp Limit 6 to 21 6 C to 21 C adjustment in 1 C steps 1 Optimisation 8 0P 0 Optimisation disabled 1 Optimisation enabled 1 Remote Control Setpoint e g via telephone module 9 tS 0 Disabled 1 Enabled 1 Second Temperature Sensor 10 SS 0 No sensor fitted 1 2 1 Outside Temperature Sensor fitted 2 Remote Temp Sensor fitted 1 Temperature Offset 12 tO 0 No offset 3 to 3 3 C to 3 C adjustment in 0 1 C s...

Page 6: ...r lights near doors or windows or in direct sunlight MOUNTING The CM907 TRV thermostat can be mounted directly on the wall surface or on an electrical wallbox WIRING The CM907 TRV thermostat is designed for fixed wiring only and must be installed in accordance with the latest l E E regulations Ensure the wiring connection to the supply is via a fuse rated at no more than 8 amps and a Class A switc...

Page 7: ...om EN0H 8555 UK07 R0 09 06 WIRING Description Model Logo Literature Availability Spec Sheet 7 day programmable thermostat Remote Temperature Sensor Outdoor Temperature Sensor CMT907A1082 F42010972 001 F42010971 001 Honeywell Honeywell French Dutch Multi lingual Multi lingual Aug 06 Sep 06 Sep 06 ENOH8555 ENOH8554 ENOH8553 ORDERING SPECIFICATION ...