72
N3680 Decoded Engine User Guide
If this bar code is read,
the next data format, if there is one, will
be used on the data. If there is no other format, the format fails and the raw data is
output as
AB1234
.
If this bar code is read:
the data is output as:
1234AB
<CR>
ED—Check for non-numeric character
Check to make sure there is a non-numeric ASCII character at the current cursor
position. The format is aborted if the character is numeric.
Example:
Only output the data if the bar code begins with a letter
If you want only data from bar codes that begin with a letter, you can use ED to
check for the letter.
Command string:
EDF10D
If this bar code is read,
the next data format, if there is one, will
be used on this data. If there is no other format, the format fails and the raw data is
output as
1234AB
.
If this bar code is read:
the data is output as:
AB1234
<CR>
EF—Insert a delay
Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the
current cursor position. Syntax = EFnnnn where nnnn stands for the delay in 5ms
increments, up to 9999. This command can only be used with keyboard emula-
tion.a
ED
“Check for a non-numeric character” command
F1
“Send all characters” command
0D
Hex value for a CR
Summary of Contents for CF3680
Page 1: ...User Guide N3680 CF3680 Decoded Engine and 2D Imager Module ...
Page 14: ...xiv N3680 Decoded Engine User Guide ...
Page 16: ...xvi N3680 Decoded Engine User Guide ...
Page 140: ...124 N3680 Decoded Engine User Guide ...
Page 184: ...168 N3680 Decoded Engine User Guide ...
Page 201: ...N3680 Decoded Engine User Guide 185 Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Page 203: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com N36XX UG Rev C 2 17 ...