CHAPTER
2
N3680 Decoded Engine User Guide
7
PROGRAM THE INTERFACE
Introduction
This chapter describes how to program your system for the desired interface.
Program the Interface - Plug and Play
Plug and Play bar codes provide instant scan engine set up for commonly used
interfaces.
Note:
After you scan one of the codes, power cycle the host terminal to have the interface in
effect.
RS232 Serial Port
The
RS232 Interface
bar code is used when connecting to the serial port of a PC or
terminal. It also programs a carriage return (CR) and a line feed (LF) suffix, baud
rate, and data format as indicated below. It also changes the trigger mode to man-
ual.
Option
Setting
Baud Rate
115,200 bps
Data Format
8 data bits, no parity bit, 1 stop bit
RS-232 Interface
TERMID0;232BAD9;232WRD2