N3680 Decoded Engine User Guide
145
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the
entire
set of
commands available for the particular storage table indicated by the Storage field
of the command. In this case, the SubTag and Data fields should not be used
because they are ignored by the device.
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to the sub-
set of commands available that match the Tag field. In this case, the Data field
should not be used because it is ignored by the device.
Data Field Usage
When a query is used in place of the Data field, the query applies only to the spe-
cific command identified by the Tag and SubTag fields.
Concatenation of Multiple Commands
Multiple commands can be issued within one Prefix/Storage sequence. Only the
Tag, SubTag, and Data fields must be repeated for each command in the sequence.
If additional commands are to be applied to the same Tag, then the new command
sequence is separated with a comma (,) and only the SubTag and Data fields of the
additional command are issued. If the additional command requires a different Tag
field, the command is separated from previous commands by a semicolon (;).
Responses
The device responds to serial commands with one of three responses:
When responding, the device echoes back the command sequence with the status
character inserted directly before each of the punctuation marks (the period, excla-
mation point, comma, or semicolon) in the command.
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example:
What is the range of possible values for Codabar Coding Enable?
ACK
Indicates a good command which has been processed.
ENQ
Indicates an invalid Tag or SubTag command.
NAK
Indicates the command was good, but the Data field entry was out of the allowable
range for this Tag and SubTag combination, e.g., an entry for a minimum message
length of 100 when the field will only accept 2 characters.
Summary of Contents for CF3680
Page 1: ...User Guide N3680 CF3680 Decoded Engine and 2D Imager Module ...
Page 14: ...xiv N3680 Decoded Engine User Guide ...
Page 16: ...xvi N3680 Decoded Engine User Guide ...
Page 140: ...124 N3680 Decoded Engine User Guide ...
Page 184: ...168 N3680 Decoded Engine User Guide ...
Page 201: ...N3680 Decoded Engine User Guide 185 Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Page 203: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com N36XX UG Rev C 2 17 ...