Maintenance
Charge the Battery
You can charge the battery via an IntelliDox module, the charger adaptor & USB Charger, and the
Multi-unit Cradle Charger.
Note:
The lithium battery may require 5 hours to full capacity. While charging, the battery icon will flash
amber once per second. The time needed to charge will increase if the apparatus is activated. The
detector may be warm during charging; this is normal. To preserve the life of the battery,
deactivate the device when not in use.
The battery operating temperature is -40°C~ +60°C.
WARNING
The Icon uses a lithium battery that may present a risk of fire or chemical burn hazard if misused.
Do not disassemble, heat above 100°C, or incinerate.
CAUTION
l
To avoid personal injury and property damage, adhere to the following:
l
Charge the battery immediately when the apparatus emits a low battery alarm.
l
Charge the battery in a safe area that is free of hazardous gas in a temperature range from
0~45°C.
l
If the device is out of charging range, the battery icon flashes in blue.
l
Charge the battery using Honeywell charger adapters designed for this apparatus only. Do not
use any other charger adapters. Failure to adhere to this caution can lead to fire and explosion.
l
If replacing the battery, use only approved lithium polymer cells that are available through
Honeywell. User of any other cell can cause fire and explosion.