GasAlertMicro
User Manual
It is recommended that BAM certified detectors be calibrated
once every 90 days
IECEx
ABS type approved:
VA-348-169-X
O
2
measuring function:
BAM/ZBA/008/04
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules and ICES-003 Canadian EMI requirements.
These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interferences to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference with radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following
measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and
receiver.
•
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV
technician for help.
General Specifications for Datalogger Units
Media type:
MMC (MultiMediaCard)
Size:
32 MB (standard); 64 and 128 MB cards available
Storage:
500,000 lines of data available; 4.4 months at
5 second intervals (based on a normal workweek)
Memory type:
Wrap-around memory ensures most recent
data is always saved
Sample rate:
One reading every 5 seconds (standard)
Data recorded:
All sensor readings, all alarm conditions,
calibrations, event flags, battery status, sensor status,
confidence beep activation, and detector status along with
the time and date for each reading and unit serial number
MMC card test:
Automatically on activation
GasAlertMicro with User Downloadable
Datalogger
Operation:
Requires no user intervention (automatic)
Indicators:
Icon advises Datalogger is operating normally,
MMC missing/malfunction advise
Compatible with:
Desktop PC computer or laptop
Operating system:
Windows 95 or higher; Macintosh OS
8.6 or higher
Download via:
MMC card reader
Card alarm:
MMC fail or missing