Section 3: Programming the 7845GSM
3-13
PROMPTS ZONE
TRIG.
4204/
2-4204
ENTRY OPTIONS
DESCRIPTION
25
Telco Zone
(0)_
✔
✔
Zone Trig: [3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
See "Important Information Regarding Zone
Input Options" on previous page.
Enter the zone number to be used for telco line
fault reports. This zone assignment must be
unique from the open/close zone selected in
Prompt 26.
Zone Trigger Mode:
If any zone is
programmed for "report only if armed," zone 7
cannot be used. If Lynx Panic is enabled, zone
3 cannot be used.
4204 Mode:
If any zone is programmed for
"report only if armed," zone 4 cannot be used
as a telco zone.
2-4204 Mode:
If any zone is programmed for
"report only if armed," or if tamper reporting
is enabled, zone 8 cannot be used.
NOTE:
Connect the telco line fault output (or
relay output programmed for "telco line fault") to
the telco zone.
26
Open/Close Zone
(0)_
✔
✔
Zone Trig: [3-7]
4204 : [1-4]
2-4204: [1-8]
[0] = not used
Enter the zone number to be used for open/close
(arm/disarm) reports. This zone assignment
must be unique from the telco zone selected in
Prompt 25.
Zone Trigger Mode:
If any zone is
programmed for "report only if armed," zone 7
cannot be used. If Lynx Panic is enabled, zone
3 cannot be used.
4204 Mode:
If any zone is programmed for
"report only if armed," zone 4 cannot be used
as an open/close zone.
2-4204 Mode:
If any zone is programmed for
"report only if armed," or if tamper is enabled,
zone 8 cannot be used.
NOTE:
Connect an open/close (arm/disarm)
trigger (or relay output) from the control panel to
the open/close zone.
27
Zn1 Trigger Type
(V+)_
✔
•
(EOLR)
•
(V+)
•
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
28
Restore Zn1 Y/N
(Y)_
✔
✔
[Y], [N]
Enables restore reporting for zone 1.
29
Delay Zn1 (secs)
(00)_
✔
✔
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 1.
30
Rpt Zn1 ONLY if
Armed (N)_
✔
✔
[Y], [N]
Reports alarms on zone 1 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; or zone 8 in 2-4204 mode)
is triggered (armed).
If [N], always reports alarms on zone 1.
31
Invert Zn2 Y/N
(N)_
✔
[Y], [N]
Inverts the alarm and normal states of the zone
2 trigger; otherwise uses normal input signal.
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM