7845GSM/7845GSMCN Installation and Setup Guide
3-4
PROMPTS ENTRY
OPTIONS
DESCRIPTION
6
Enter Password
[0-9, A-F, N,
S, T, X, Y]
This prompt is displayed if [Y] was pressed in Prompt 4
or 5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
Re-enter the password as confirmation.
If the password doesn't match the first entry, the
following is displayed followed by the "Exit Prog.
Mode?" prompt:
7
[0-9, A-F, N,
S, T, X, Y]
Verify Not OK
PSWD not created
Verify Password
Otherwise, the "Exit Prog. Mode?" prompt is displayed
directly.
8
Exit Prog. Mode?
(Y/N)_
[Y], [N]
[ESC]
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the
Exiting Programming Mode
paragraph in
this section.
9
Device Mode
(ECP)_
•
ECP
•
Zone Trig.
•
4204 Emu
•
Two 4204s
Press the [space] key to scroll through the modes of
operation
.
Press [ENTER] to select
ECP
mode.
See
Table 5
if programming other modes.
Important Information Regarding Primary and Secondary Accounts (Questions 10-16)
Account information is provided by the central station administrator. If the control supports secondary account
reporting, you will need secondary account information. The City ID, CS ID or Subscriber ID of the secondary
account must differ from that of the primary account.
10
Primary City ID
(??)_
[01-99]
Enter the 2-digit primary city ID, 01-99 (decimal).
11
Primary CS ID
(???)
[01-FE]
Enter the 2-digit primary central station ID number,
01-FE (HEX).
12
Primary Sub ID
(????)
[0001-9999]
Enter the 4-digit subscriber account number, 0001-
9999 (decimal).
13
En. 2
nd
CS Y/N
(N)_
[Y], [N]
Applicable only if control supports Central Station #1
and #2 Category Enable reporting for the LRR device
(e.g., VISTA-128BP, FA1660C, etc.).
Used if reporting to a second central station is desired.
If [N], go to Prompt 17: "Device Address."
14
2
nd
City ID
(??)_
[01-99]
Enter the 2-digit secondary city ID, 01-99 (decimal).
15
2
nd
CS ID
(??)_
[01-FE]
Enter the 2-digit second central station's ID number,
01-FE (HEX).
16
2
nd
Sub ID
(????)_
[0001-9999]
Enter the 4-digit subscriber account number for the
second central station, 0001-9999.
17
Device Address
(03)_
[01-30]
In ECP mode, the 7845GSM communicates with the
panel as a Long Range Radio (LRR) device. Enter the
appropriate ECP device address. For VISTA-10 and
VISTA-20 series control panels, use address 03. For
other controls, see the control panel’s Installation and
Setup Guide.
NOTES:
1. When programming the control, enable the LRR
output.
2. The device address must be unique from the
"Direct Wire Addr" entered in Prompt 19.
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM