ACUIX IP Rugged Housing and Dome Installation Guide
Document 800-02460 Rev A
21
08/08
Note
The mounting bracket can be at any angle from 0° to 90° with respect to the
housing. The housing must be positioned horizontally and parallel to the
floor.
4.
To change the orientation of the bracket:
a.
Loosen and remove the two bolts that secure the bracket to the housing.
b.
Slide the bracket along the slot to remove it from the housing.
Step 5: Install the Scan Assembly into the Housing
1.
Carefully remove the plastic lens cap from the scan assembly. Do not touch the
lens.
2.
Rotate and line up the scan assembly yellow label to the mounted housing yellow
label. See
for the location of the scan assembly label and locking guides.
3.
Gently push the scan assembly into the housing until the two guides on the scan
assembly lock/snap into the holes on the housing guides.
4.
Gently pull down on the assembly to ensure it has properly latched into place.
Figure 1-7
Insert the Scan Assembly into the Housing
Scan assembly locking guides
Up
Rotate to align with the
housing yellow labels