Commissioning
Page 24
3.4.3 Level calibration using the top of ball valve
If level dipping is not possible, the 854 ATG can be calibrated using the top of a ball valve as reference point.
Proceed as follows:
Item
Name
Description
W2
=
Protection level 2
Enter protection level 2 password
CA
Calibrate
The displacer will be raised until it stops against the flange of the level
gauge.
►
Make sure the displacer is positioned above the ball valve.
Close the ball valve.
UN
Unlock
Unlock the gauge and wait the displacer reaches the top of the ball
valve.
►
Calculate the immersion depth of the displacer at the product
interface (for a 90 mm displacer use 3 mm; for a 45 mm
displacer use 12 mm).
RL
= Reference level
Format according to item
LD
. Enter the position of the top of the ball
valve with respect to the tank zero adding the immersion depth of the
displacer at the product level.
AR
Accept reference
By giving this command, the level value entered in item
RL
, is
accepted as level value and will be shown on the display.
EX
Exit
Exit protection level.
CA
Calibrate
The displacer will now raise from the ball valve.
Let it stop against the flange or give a
FR
(freeze) command.
►
Open the ball valve.
UN
Unlock
Unlock the gauge. The displacer will now move down till it reaches the
level.
For verification of the level calibration, refer to section 4.8.2.
Caution
If a 45 mm displacer is used, stop immediately the Calibrate command
as soon as the displacer is above the ball valve,
followed by an
FR
(freeze) command.
Summary of Contents for 854 ATG Series
Page 1: ...Instruction manual Series 854 ATG level gauge ...
Page 2: ......
Page 53: ...Appendix Instruction manual 854 ATG Page 51 ...
Page 55: ...Appendix Instruction manual 854 ATG Page 53 ...
Page 56: ...Appendix Page 54 Appendix C ASCII table ...
Page 58: ...Appendix Page 56 Level display format B Average gas temperature display format C ...
Page 60: ...Appendix Page 58 HIMS pressure displays format F and H Servo density display format I ...
Page 62: ...Appendix Page 60 Appendix E PCB layout XPU 2 HCU HCU SPU II GFC ...
Page 67: ......