background image

     5898 Wireless DUAL TEC

®

 Motion Sensor  - Installation Instructions 

 

 

PRELIMINARY DRAFT 5/18/09

 

5 -

 

DETECTION PATTERNS / COUVERTURE DE DETECTION /  PATRON DE DETECCIÓN  

50’ / 15m Wide Angle Lens /  

Wide Angle Lens /

  

Wide Angle Lens /

   

(P/N 5-532-439-01 – Installed)

 

Top View / VUE DE DESSUS / VISTA DESDE ARRIBA 

 

 

 

35’ / 11m Animal Immune Lens / 

Animal Immune Lens /

 

Animal Immune Lens  

(P/N 5-532-489-01 – Included)

 

Top View / VUE DE DESSUS / VISTA DESDE ARRIBA 

 

 

 

 

 

 
 

LENS MASKING / 

LENS MASKING / LENS MASKING /  

 
 

5

-5

3

2

-4

3

9

-0

1

TOP

5

0

FT

 

LENS MASKING / 

LENS MASKING / LENS MASKING /  

 
 

5

-5

3

2

-4

8

9

-0

1

TOP

2

5

 /

 3

5

F

T

 

Side View / VUE DE COTE /  VISTA LATERAL 

 

 

Side View / VUE DE COTE / VISTA LATERAL 

 

Summary of Contents for 5898

Page 1: ...h a robust wall anchor ON 2 3 4 1 ON 2 3 4 1 PIR Sensitivity LOW Pulse Count 2 Up to 100 lb 45 kg Animal Immunity FR CA PIR Sensitivity LOW Pulse Count 2 Up to 100 lb 45 kg Animal Immunity SP Amer PIR Sensitivity LOW Pulse Count 2 Up to 100 lb 45 kg Animal Immunity PIR Sensitivity HIGH Pulse Count 1 Up to 50 lb 22 6 kg Animal Immunity FR CA PIR Sensitivity HIGH Pulse Count 1 Up to 50 lb 22 6 kg An...

Page 2: ...ensor If necessary adjust the microwave range pulse count or sensitivity setting For LED activation meaning refer to the LED Indicator table 4 MICROWAVE WALK TEST 10 MINUTES 1 Set the Microwave Walk Test DIP switch to ON or toggle it ON and OFF 2 Set Range Adjustment potentiometer to 25 and replace the cover 3 Walk through the detection area and observe the LED 4 If necessary adjust the potentiome...

Page 3: ...the LED 4 If necessary adjust the potentiometer until desired detection range is obtained For LED activation meaning refer to the LED Indicator table Power Up Trouble or Anti Mask Fast Blinking Red LED Enabled or Disabled Condition Indicator LED Slow Blinking Red will finish within 60 seconds Indicator LEDs Normal Walk Test Red ON for 3 seconds if Alarm Yellow ON for 2 seconds if Microwave event d...

Page 4: ...the LED 4 If necessary adjust the potentiometer until desired detection range is obtained For LED activation meaning refer to the LED Indicator table Power Up Trouble or Anti Mask Fast Blinking Red LED Enabled or Disabled Condition Indicator LED Slow Blinking Red will finish within 60 seconds Indicator LEDs Normal Walk Test Red ON for 3 seconds if Alarm Yellow ON for 2 seconds if Microwave event d...

Page 5: ...e Lens P N 5 532 439 01 Installed Top View VUE DE DESSUS VISTA DESDE ARRIBA 35 11m Animal Immune Lens Animal Immune Lens Animal Immune Lens P N 5 532 489 01 Included Top View VUE DE DESSUS VISTA DESDE ARRIBA LENS MASKING LENS MASKING LENS MASKING 5 532 439 01 TOP 50FT LENS MASKING LENS MASKING LENS MASKING 5 532 489 01 TOP 25 35FT Side View VUE DE COTE VISTA LATERAL Side View VUE DE COTE VISTA LAT...

Page 6: ...reless DUAL TEC Motion Sensor Installation Instructions PRELIMINARY DRAFT 5 18 09 6 LENS CHANGE INSTRUCTIONS LENS CHANGE INSTRUCTIONS LENS CHANGE INSTRUCTIONS LENS CHANGE INSTRUCTIONS LENS CHANGE INSTRUCTIONS ...

Page 7: ...5898 Wireless DUAL TEC Motion Sensor Installation Instructions PRELIMINARY DRAFT 5 18 09 7 ...

Page 8: ...rate this equipment IC NOTICE This Class B digital device complies with the Canadian RSS 210 Cet appareil numérique de la Classe B est conforme à la norme CNR 210 du Canada This Class B digital device complies with RSS 210 of the IC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received inc...

Reviews: